• Title/Summary/Keyword: Drilling Procedure

Search Result 67, Processing Time 0.026 seconds

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

A Case Report on the Sea-Trial of the Seabed Drill System and Its Technical Trend (해저 착저식 시추기 시험시추 보고 및 기술 동향)

  • Pak, Sang Joon;Kim, Hyun-Sub
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.479-490
    • /
    • 2016
  • Seabed drilling system has recently been used to drill seafloor mineral resources. This case report highlights the procedure and result of sea-trial of seabed drilling system at off-shore of Japan on March, 2016 as well as briefs an international-technical trend of seabed drilling system. In case of having less than 100 m drill depth, seabed drilling system is favorable for seafloor mineral deposits which are mostly distributed within a narrow district and situated between 1000~3000 m water depth, compared with vessel-mounted drilling system. The system is featured by the remotely-operated drill gear, which has top drives, drill strings and mud system on it. The core samples are generally recovered to ship with seabed driller after a dive. In this sea-trail, recovery rate of core samples averagely shows about 55% and the recovered rocks mostly correspond to fresh and/or weak-altered basalt. In case of drilling hydrothermal ore deposit, the recovery rate would be lower than 55% because of the fragile nature of ores. Alternatively it is used to collect cutting chips through riser or bins in order to increase the recovery rates. Recently a reverse circulation method is taken considered to acquire the better cutting-chips. Three-leg type outrigger system and four-leg type leveling system are the competing landing-instruments of seabed drill system. However the landing efficiency using these gears has to be further monitored due to lack of case reports.

A Computational Platform for Nonlinear Analysis of Prestressed Concrete Shell Structures

  • Kim, Tae-Hoon;Shin, Hyun-Mock
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.6
    • /
    • pp.593-606
    • /
    • 2010
  • This paper presents a formulation to include the prestressing effects in available numerical models for the nonlinear material, instantaneous and long-term analysis of prestressed concrete shell structures, based on the displacement formulation of the finite element method. A four-node flat shell element is adopted for nonlinear analysis of prestressed concrete shells. This element was incorporated into an existing general-purpose finite element analysis program. A distinctive characteristic of the element is its capability to simulate the behavior of shells subjected to a variety of types of loading and drilling rotational stiffness. Consequently, the response of prestressed concrete shell structures can be predicted accurately using the proposed nonlinear finite element procedure.

A STUDY ON THE HEAT GENERATION OF BONE DRILLING BURS ACCORDING TO IRRIGATION DURING IMPLANTATION OF DENIAL IMPLANT (치과 임플랜트 식립시 관주에 따른 골 천공 기구의 열 발생에 관한 연구)

  • Moon, Eun-Soo;Lim, Heun-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.433-453
    • /
    • 1999
  • There are a lot of elements affecting the success of implant prosthesis. The quality of surgical procedure is considered as one of the key factors. To avoid the excess heat generation is an important element of successful osseointegration and it can be achieved by using a gentle surgical technique with a sharp instrument in bone drilling. This study was performed to measure and analyze comparatively the heat transmitted to sur-rounding bone at a distance of 0.5mm from the periphery of the drill hole in each drilling stage. The results were as follows. In standard system, the temperature of surrounding bone tissue ranged from $29.2^{\circ}C\;to\;48.3^{\circ}C$ with irrigation and from $34.6^{\circ}C\;to\;84.3^{\circ}C$ without irrigation. And in wide system, the temperature of surrounding bone tissue ranged from $29.5^{\circ}C\;to\;52.5^{\circ}C$ with irrigation and from $34.8^{\circ}C\;to\;87.8^{\circ}C$ without irrigation. And the temperature ranges exceeded the threshold without irrigation, while showing less than the threshold by the cooling effect of irrigation. In comparing standard system with wide system, although there was no significant difference, ${\phi}4.3mm$ pilot and ${\phi}4.3mm$ twist drill of wide system showed high value and wide system showed slightly high elevation of temperature in all depth in fixture installation. In the finite element analysis, the calculated value by the Fourier's cooling law were applied to the bone drilling surface. And through analysis using different irrigation temperatures at $28^{\circ}C,\;15^{\circ}C\;and\;5^{\circ}C$, and according to the time. The result was that the cooling water at least below $15^{\circ}C$ was required to maintain the temperature of surrounding bone less than threshold in bone drilling, the cooling water below $5^{\circ}C$ was required to gain more sufficient cooling effect, and cooling over 5 seconds was needed after bone drilling for sufficient effect.

  • PDF

Painful Accessory Navicular (동통성 부 주상골)

  • Jung, Hong-Geun;Park, Jong-Tae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Accessory navicular is a congenital anomaly of the tuberosity of the navicular from a secondary ossification center. The accessory navicular is occasionally the source of pain and local tenderness over the medial side of midfoot. If conservative treatment fails for the painful accessory navicular, surgical treatment is required. There are several surgical option for accessory navicular, which vary from simple excision, percutaneous drilling, modified Kidner procedure and osteosynthesis of the accessory ossicle to the navicular body. In addition, symptomatic flatfoot deformity should be addressed concomitantly.

A Study on the Performance Evaluation of a Voice Coil Actuator for Electro-Discharge Micro-Drilling Machine (보이스코일 액츄에이터로 이송되는 미세구멍 가공용 방전 가공기의 작동특성 연구)

  • Yang, Seung-Jin;Baek, Hyeong-Chang;Kim, Byeong-Hui;Jang, In-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.152-158
    • /
    • 2001
  • In this paper, we have developed an electro discharge machine for micro drilling driven by a voice coil actuator. Because the voltage signal of the electro-discharging circuit shows a lot of peaks and valleys, the active type low-pass filtering technique is adopted to get the average of the signal. Since the motion of the voice coil is precisely controlled by the error value between the object voltage value and the measured one, it is possible to prevent the mechanical contact between the rotating electrode and the workpiece and to maintain the appropriate machining conditions during the process. The electro-chemical machining technology was also adopted to make small diameter electrodes. Pure water is used as a dielectric. The machining procedure is performed to verify the feasibility of the developed system. It takes about 10 seconds to drill the ${\phi}m$100${\mu}m$ hole to the 100${\mu}m$ thickness stainless steel plate. The machining time depends on the values of the resister and the capacitor. There may exist the optimal values of time constant and the tendency is displayed In the appendix.

  • PDF

The Theory of Load Estimation Method and Case Study of Hydraulic Breaker for Rock Drilling (진동기반 하중 추정기법의 이론 및 암반 천공용 유압 브레이커 적용사례)

  • Kim, Dae-ji;Cho, Jung-Woo;Oh, Joo-Young;Chung, Jintai;Song, Changheon
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.135-147
    • /
    • 2019
  • This paper introduced a impact load estimation method by examining vibration transfer path analysis (TPA). The theoretical background and the load quantification procedure are explained, and a case study of hydraulic breaker is reported. We explained the merits and limitations of the load estimation method of TPA, and improvement method was suggested through case analyses of drilling equipment. The necessity of R&D of load-estimation technology was discussed. A new strategy for developing new techniques for impact load measurement was proposed.

A Study on the Drilling Characteristics for Implant Procedure Drill (임플란트 시술용 드릴의 가공 성능 평가에 관한 연구)

  • Lee, Sang-Min;Chae, Seung-Su;Lee, Jae-Kun;Choi, Hwan;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.49-54
    • /
    • 2014
  • Skull Melted 3.2YSZ has good physical properties and does not undergo low temperature degradation. Due to these excellent physical and mechanical properties, Skull Melted 3.2YSZ has been studied for use in dental implants. In this study, a ø2.2mm Initial Twist Drill was made using Skull Melted 3.2YSZ; the drilling characteristics were compared with those of the traditional SUS420J drill. The experimental results indicate that the Skull Melted 3.2YSZ drill requires similar thrust forces and has a slightly higher temperature.

Practical Applications of DNA Marker-Assisted Selection and OPU-Derived IVF Embryo Transfer for the Production of High Quality Meat in Hanwoo II. Production of IVF Embryos Derived Transvaginal Ovum Pick-up from DNA Marker-Proved Hanwoo (유전자 분석을 통하여 선발된 한우로부터 초음파 유래 체외수정란 이식에 의한 고품질 한우 생산기술의 실용화 II. DNA 검정우로부터 초음파 유래 체외수정란의 생산에 관한 연구)

  • 박희성;이지삼;진동인;박준규;홍승표;이명열;정장용
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.193-201
    • /
    • 2001
  • This study was designed to examine the factors affecting in fertilization and development of embryos in vitro, and to examine whether zone drilling by laser irradiation can improve the hatching rate of IVF embryos from DNA marker-proved Hanwoo. DNA markers related to marbling score were identified using DNA fingerprinting with Ml3 probe and restriction enzyme Hae III. Oocytes were aspirated from immature ovarian follicles using a combined method of rectal ovarian-palpation and transvaginal ultrasound-guidance(6.5MHz) under local anesthesia. The aspirated oocytes were washed twice with fresh D-PBS containing 5% FBS and were rewashed 4 to 5 times with TCM-199 containing 5% FBS. A morphological grade of I to IV was assigned to each oocyte. Data were analyzed using the GLM procedure of SAS. Sperm separation methods did not have any significant effect on cleavage or developmental abilities of IVF embryos. Significantly(P<0.05) higher cleavage rate was observed in embryos from GI(60.0%, 3/5), GII(69.2%, 18/26) and GIII(62.1%, 59/95) compared to embryos from GIV oocytes(36.2%, 25/69). And the developmental rate to blastocyst stage was higher(P<0.05) in embryos from GI(33.3%, 1/3) and GII oocytes(38.9%, 7/18) than those from GIII(16.9%,10/59) and GIV oocytes(4.0%, 1/25). There was no significant difference in development of IVF embryos to blastocyst by media for in vitro culture. Proportion of hatched blastocyst was significantly(P<0.05) higher in embryos received zona drilling by laser than those of non-drilled.

  • PDF

The effect of guided flapless implant procedure on heat generation from implant drilling (수술가이드를 이용한 무피판 임플란트 술식에서 임플란트 드릴링이 열발생에 미치는 효과)

  • Yoo, Je-Hyeon;Jeong, Seung-Mi;Choi, Byung-Ho;Joo, Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the heat generation in bone in vitro during the guided flapless drilling procedure and the effect of drilling methods on the heat generation. Materials and methods: A model that has missing the first and second mandibular molars bilaterally was used. In group A, classical flap implant surgery was performed. In group B, flapless implant surgery using surgical guide was performed. In group C, flapless implant surgery using surgical guide without up-and-down pumping motion was performed. Temperature was measured with k-type thermocouple and a real-time digital thermometer. The thermocouples were placed at 0.5 mm away from the osteotomy area at the depths of 3 mm and 6 mm. The measured values were evaluated with independent t-test. Results: The mean temperature generated was $27.2^{\circ}C$ ($SD{\pm}2.1^{\circ}C$) and $27.5^{\circ}C$ ($SD{\pm}2.3^{\circ}C$) for groups A and B, respectively. These differences were not statistically significant. In group C, the mean temperature was $37.0^{\circ}C$ ($SD{\pm}3.4^{\circ}C$). There were statistically significant differences between groups B and C with respect to the mean temperature. Conclusion: These findings suggest that guided flapless drilling with up-and-down pumping motion may not significantly increase the bone temperature.