• 제목/요약/키워드: Drilled Shaft

검색결과 177건 처리시간 0.021초

탑다운 기초 현장타설말뚝의 지지력 평가 (Bearing Capacity Evaluation of Drilled Shaft for Top & Down Method)

  • 조천환;김홍묵;김웅규;권세오;성병완
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.58-65
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a Quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method.However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. It may be a small scale test pile could be an alternative as a quality assurance for the drilled shaft with high capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

  • PDF

국내 암반에 근입된 현장타설말뚝의 소켓벽면 거칠기에 관한 연구 (A Study on the Surface Roughness of Drilled Shaft into Rock in Korea)

  • 이명환;조천환;유한규;권형구
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.431-438
    • /
    • 2003
  • The domestic design method for the shaft resistance of drilled shafts into a bedrock Is based on the empirical method, where the uniaxial compressive strength of rock specimen is utilized for calculation of the shaft resistance. This method has uncertainties in prediction of capacity of drilled shafts and result in uneconomic engineering design. Recently a new improved design method was suggested, which reflects important factors that affect the strength of pile sockets. Socket roughness is one of significant factors influencing the shaft resistance of drilled shaft socketed into rock In this paper roughness information for the shaft resistance design of socket pile was suggested on the basis of statistical analysis of data measured from wall surface In the bore holes of drilled shafts.

  • PDF

정재하시험을 통해 산출되는 현장타설말뚝의 지지력이론식 비교연구 (Comparison of Bearing Capacity Equations for Rock Socketed Drilled Shalt Based on the Results of Static Pile Load Test)

  • 천병식;황성식;이승범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.333-340
    • /
    • 2003
  • In Korea, drilled shaft are generally socketed into rock. Driven pile has environmental problems such as vibration and noise. Therefore, applications of the drilled shaft are increasing in Korea. In this paper, static load test data of the rock socketed drilled shaft at Gwangandaero and Suyeong 3hogyo are analyzed. The bearing capacities from field test data and theoretical formula are compared and analyzed. From this study, design approaches for drilled shafts in Korea are examined and several suggestions are proposed.

  • PDF

Centrifuge modelling of rock-socketed drilled shafts under uplift load

  • Park, Sunji;Kim, Jae-Hyun;Kim, Seok-Jung;Park, Jae-Hyun;Kwak, Ki-Seok;Kim, Dong-Soo
    • Geomechanics and Engineering
    • /
    • 제24권5호
    • /
    • pp.431-441
    • /
    • 2021
  • Rock-socketed drilled shafts are widely used to transfer the heavy loads from the superstructure especially in mountainous area. Extensive research has been done on the behavior of rock-socketed drilled shafts under compressive load. However, little attention has been paid to uplift behavior of drilled shaft in rock, which govern the overall behavior of the foundation system. In this paper, a series of centrifuge tests have been performed to investigate the uplift response of rock-socketed drilled shafts. The pull-out tests of drilled shafts installed in layered rocks having various strengths were conducted. The load-displacement response, axial load distributions in the shaft and the unit skin friction distribution under pull-out loads were investigated. The effects of the strength of rock socket on the initial stiffness, ultimate capacity and mobilization of friction of the foundation, were also examined. The results indicated that characteristics of rock-socket has a significant influence on the uplift behavior of drilled shaft. Most of the applied uplift load were carried by socketed rock when the drilled shaft was installed in the sand over rock layer, whereas substantial load was carried by both upper and lower rock layers when the drilled shaft was completely socketed into layered rock. The pattern of mobilized shaft friction and point where the maximum unit shaft friction occurred were also found to be affected by the socket condition surrounding the drilled shaft.

축소모형말뚝을 이용한 현장타설말뚝의 지지력 평가 (Bearing Capacity Evaluation of the Drilled Shaft Using Small Scale Model Test)

  • 조천환;김홍묵;김웅규
    • 한국지반공학회논문집
    • /
    • 제20권5호
    • /
    • pp.117-126
    • /
    • 2004
  • 최근 건축구조물이 대형화됨에 따라 현장타설말뚝을 이용한 Top-Down공법이 공기단축 및 경제성 등의 이유로 자주 채택되고 있다. Top-Down 기초로 시공되는 현장타설말뚝의 경우 설계하중이 크다는 이유로 인해 품질확인용 재하시험을 생략하는 경우가 대부분이며, 대규모 설계하중을 검증하기 위한 전통적인 재하시험 방법 또한 적용하기 곤란한 경우가 많다. Top-Down 공법에 있어 건축구조물의 대형화에 의한 현장타설말뚝의 사용하중이 증대됨에 따라 현장타설말뚝에 대한 품질확인은 점차 중요시되고 있으며, 이에 대한 대안으로서 축소모형말뚝을 이용한 시험방법의 적용이 가능할 것으로 판단된다. 본 연구에서는 대구경 현장타설말뚝의 지지력 측정시 전통적인 재하시험 방법의 한계를 극복하기 위하여 축소모형말뚝을 이용하는 방안을 제시하였으며 특히, 시험결과의 해석을 위해 암반에 근입된 현장타설말뚝의 치수효과에 관한 분석 방법을 제안하고 평가해 보았다.

단일 현장타설말뚝 기초의 설계 및 시공 (Design and consturction of single drilled shaft foundation)

  • 전경수;김경석;김정열
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.86-100
    • /
    • 2006
  • The single drilled shaft foundation has been used in the other countries, but has not used in South Korea at all This foundation is very effective and economic method in South Korea which is easy to meet a good rock mass within 50m depth from the ground We have many experiences to construct 1.52 5m drilled shaft foundations and ability to construct 30m drilled shaft foundation without special efforts The soil behavior is nonlinear, but it can be proposed in linear in practical purpose on bridges. The elastic modulus of soil can be rationally obtained by the method of Road Bridge Design Manual in South Korea using the Schmertmann(1970)'s proposal, and the elastic modulus of rock can be obtained by the field test. In seismic design the column and drilled shaft must be restricted to the elastic design because the behavior of this foundation is flexible and the arrangement of the rebars makes the various defect In this paper the design criteria is compared with FHWA design criteria, and the design criteria is proposed in consistent with Road Bridge Design Manual in South Korea. The single drilled shaft foundation of a test bridge was constructed in the Iksan-Jangsoo highway, and we checked its stability, workability and economy

  • PDF

대구경 현장타설말뚝의 지지력 측정 사례연구 (A Case Study on the Measurement and Estimation of Bearing Capacity of Large Diameter Bored Pile)

  • 이원제;정훈준;이우진;장기수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.285-292
    • /
    • 2000
  • Though there has been increasing use of large diameter drilled shaft as a foundation structure of bridges, current practice for quality control is to confirm the minimum required load carrying capacity during construction stage. For economic and appropriate design of drilled shaft, it is necessary to evaluate the load transfer mechanism by pile load tests during initial stage of construction and to use the test results as a feedback to a revision of initial design. In this paper, results of load tests peformed at several domestic sites are presented to investigate the load transfer characteristics of large diameter drilled shaft. It was found that most of the load on piles is sustained by shaft friction and that only small portion of the load reaches the bottom of the drilled shaft. Some test results of drilled shaft by Pile Driving Analyzer performed at same sites are also presented to compare the load transfer characteristics interpreted from static pile load tests.

  • PDF

지반조건이 현장 타설 말뚝 선단부의 동적 경계조건에 미치는 영향 (Effects of Soil Conditions on the Vibratory Motion of Drilled Shaft)

  • 이병식;이원구
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.159-166
    • /
    • 2000
  • Non-destructive out-hole tests, impact-echo and impact-response are widely applied to evaluate integrity of drilled shafts. In these tests, vibratory motions of drilled shafts are interpreted, which induced by impacts on the shaft head. In applying the tests to evaluating integrity of shaft, it has been attended whether the tests have resolutions enough to distinguish existence of slime at between the shaft end and a bearing soil deposit. To distinguish existence of slime by tests, modes of shaft vibrations need to be reasonably interpreted, which generally vary according to a shaft boundary condition such as, a free-free or a free-fixed condition. The boundary condition of a shaft is, however, found to be significantly affected by stiffness of soil deposits around shaft as well as penetration depths of shaft into a bearing soil deposit. Thus, these effects on the boundary condition of a shaft should be considered reasonably in interpreting test results to decide the existence of slime. To investigate the effects, in this study, vibratory motions of shafts constructed in various soil conditions and end penetration depths are examined analytically. Based on the studies, variations of boundary condition are characterized in terms of soil stiffness contrast between a shaft perimeter and a shaft end, and also the ratio of a penetration depth to a shaft length. The results can be applied to verify the applicability of tests to identify the slime.

  • PDF

Performance of Rock-socketed Drilled Shafts in Deep Soft Clay Deposits

  • Kim, Myung-Hak
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.409-429
    • /
    • 2006
  • In designing rock-socketed drilled shaft, bearing capacity evaluation is very important because the maximum values of base and side resistance are not generally mobilized at the same value of displacement, FHWA and AASHTO code suggest different ultimate bearing capacity formular according to rock type and shaft settlement. In domestic code suggest base resistance and side resistance can be added on condition that after confirming the result of field load test with axial load transfer test. This paper shows that static load test and hi-directional load test result analysis of deep rock-socketed drilled shaft in three different sites. Load-settlement curve, t-z, and q-w curve in rock-socketed part were calculated and compared. t-z curve in weathered and soft rock showed no deflection softening behavior in pretty large strain (about 2-3% of diameter). Ultimate resistance could be the summation of side resistance and base resistance in rock-socketed drilled shaft in domestic sites.

  • PDF

대구경 현장타설말뚝의 주면 마찰력 평가 (Evaluation of Skin Friction on Large Drilled Shaft)

  • 홍원표;여규권;이재호
    • 한국지반공학회논문집
    • /
    • 제21권1호
    • /
    • pp.93-103
    • /
    • 2005
  • 대구경 현장타설말뚝에 대하여 하중전이 측정을 수반한 정재하시험, 동재하시험 및 유한차분해석을 수행하여 주면 마찰력 거동특성에 대한 연구를 실시한다. 주면 마찰력은 말뚝과 지반의 상대변위와 직접적으로 관계되므로 임의의 심도에서 측정한 말뚝의 하중전이량과 유한차분해석에 의한 주면지반의 변위와 응력을 이용하여 거동특성을 분석한다. 하중전이측정결과에 의하면 현장타설말뚝 주면을 따라 발휘되는 극한단위주면 마찰력은 중간 깊이인 모래자갈층과 자갈층 상부에서 먼저 나타난다. 또한 동일한 현장타설말뚝에 대하여 동재하시험과 정재하시험을 실시한 결과 주면 마찰력과 선단지지력의 거동특성이 상이하게 평가되었으며, 그 차이점에 대하여 논의한다.