• 제목/요약/키워드: Drawdown test

검색결과 47건 처리시간 0.03초

단계양수시험 해석 방법에 따른 우물 및 수리 상수 변동 분석 (Comparisons of Different Step-drawdown Test Analysis Methods; Implication for Improrvced Analysis for Step-drawdown Test Data)

  • 안효원;하규철;이은희;도병희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권4호
    • /
    • pp.35-47
    • /
    • 2020
  • Step-drawdown test is one of the widely-used aquifer test methods to evaluate aquifer and well losses. Various approaches have been suggested to estimate well losses using the step-drawdown test data but the uncertainties associated with data interpretation and analysis still exist. In this study, we applied three different step-drawdown test analysis methods -Jacob (1947), Labadie and Helweg (1975), Gupta (1989)- to the step-drawdown test data in Seobu-myeon, Hongseong-gun, South Korea and estimated aquifer and well losses. Comparisons of different step-drawdown test analysis methods revealed that the estimated well losses showed different values depending on the applied methods and these variations are likely to be related to the limitation of the assumptions for each analysis method. Based on the detailed analysis of time-drawdown data, we performed step-drawdown test analysis after removing outlier data during the initial stage of step drawdown test. The results showed that the application of the revised time-drawdown data could substantially decrease the error of the analysis as well as the variations in the estimated well losses from different analysis methods.

유압 저하시험 모델과 자동차 연료필터의 토설율 측정 실험 연구 (A Study on Hydraulic Drawdown Test Model and Experimental Estimation of Desorption Rate Ratios of Fuel Filters)

  • 이재천;계중읍
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.205-213
    • /
    • 2003
  • This study describes the mathematical equation of drawdown test model and introduces the experimental test apparatus and procedure to estimate the desorption rate ratio of a filter. The characteristics of a hydraulic filtration system of drawdown test were demonstrated by numerical simulation for various properties of filters and operation conditions. Experiments for three kinds of fuel filters were conducted according to the proposed test method. And the test results of desorption rate ratio were compared with those values anticipated in precedent multipass filtration tests. Experimental results revealed the validation of drawdown test method proposed in this study. Domestic fuel filter yielded high desorption rate ratio comparing with other foreign products, which means that the Beta ratio decreases a lot during the test. The results also showed that filtration system model could be developed including desorption rate ratio to estimate the variable Beta ratio in service life.

단계양수시험 해석시 시간선택이 해석결과에 미치는 영향 (Effects of Selected Time on Analysis Results in Step-Drawdown Tests)

  • 이진용;송성호;이강근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제10권2호
    • /
    • pp.59-65
    • /
    • 2005
  • 단공 수리시험으로서의 단계양수시험은 일반적으로 대수층 및 우물의 생산성 혹은 효율을 평가하기 위해 수행되어 왔다. 단계양수시험은 기본적으로 초기에 저양수량으로 양수를 하며 양수관정의 수위가 안정되면 다음 단계의 고양 수량으로 다시 수위가 안정될 때까지 양수를 지속한다. 이러한 과정은 최소 3단계 이상 반복되며 각 단계별 양수지속시간을 동일하여야 한다. 본 기술자료에서는 그 동안 국내에서 수행된 단계양수시험의 해석과 관련하여 몇 가지 문제점들을 살펴보았다. 그 결과 단계양수시험에 대한 부적절한 해석결과는 주로 잘못된 해석개념 및 불완전한 현장 양수자료와 관계가 큰 것으로 파악되었다.

대종천유역 충적대수층의 수리성 분석 및 수위강하예측에 관한 연구 (Analysis of Pumping Test Data and The Prediction of Drawdown for Daejong-Chun Area)

  • 최재진;성원모;한정상
    • 자원환경지질
    • /
    • 제26권4호
    • /
    • pp.541-549
    • /
    • 1993
  • The main goal of this paper is to determine hydraulic properties and to predict drawdown for the efficient and stable development of groundwater in the Daejong-Chun area, North of Kyungsang-Do. Based on geological survey and analysis of well logging data conducted in 1991, it is found that the type of aquifer of this area is considered to be an anisotropic unconfined aquifer with saturated thickness of 19.8 m. In order to characterize this aquifer pumping test was conducted, and the resulting drawdown data were utilized for the analysis by applying both type curve matching technique and semi-log straight line method. As a result, the average specific yield of this aquifer is estimated as 32.3%, and the average ratio of $K_H$ to $K_V$ is only 2.7, which means that gravitational effect is not significant factor for this type of aquifer. For the validation of the estimated hydraulic properties, the analytical model which was developed with Newton-Raphson iteration procedure in this study, was employed to generate the drawdown. And, the resulting drawdown was compared against actual drawdown data and it shows the excellent matches. The actual drawdown data for 9 hours of pumping were used for history matching purposes and relatively satisfactory matches were achieved in this match. Then, the model was run by using the tuned parameters that are obtained during history matching stage, and the drawdown was predicted for the next 30 years of pumping with $3,000m^3/day$ of constant pumping rate. Its result indicates that the drawdown was stabilized as 1.41 m from 20 days with $3,000m^3/day$ of constant pumping rate, which is the required amount of water to be safely supplied to this area.

  • PDF

국가지하수 관측망의 양수시험 자료 해석을 통한 대수층 특성 분석

  • 전선금;구민호;김용제;강인옥
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.487-491
    • /
    • 2004
  • For tile hydrogeological data of the National Groundwater Monitoring Wells(NGMW), a statistical analysis is made to reveal aquifer characteristics of the country. Results of the pumping and recovery test are classified into 4~5 types by the pattern of drawdown and residual drawdown curves. The analysis of aquifer characteristics shows that the hydraulic conductivity of alluvial aquifers is greater than that of fractured-rock aquifers. The hydraulic conductivity of alluvial aquifers slightly increases as the distance to the discharge area decreases. 77.5% of the NGMWs, where the distance to the discharge area is more than 100m, shows the constant head boundary. This result suggests that the fractured and the alluvial aquifers are fairly interconnected, and water can be supplied from one aquifer to tile other where pumping tests are performed. It is analyzed that the wells showing the impermeable boundary are influenced by small scale of aquifers, poor aquifer transmissivities, and impermeable layers.

  • PDF

변동량 분석을 이용한 암반대수층의 수리학적 매개변수 산출 (Estimation of Hydraulic Parameters of a Fractured Rock Aquifer Using Derivative Analysis)

  • 김범수;양동철;여인욱
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.46-52
    • /
    • 2010
  • Derivative analysis, based on the derivative of the drawdown as a function of time (i.e., rate of drawdown change), was applied to the evaluation of hydraulic parameters of the aquifer as an aid of the aquifer test interpretation based on the Theis solutions. Pumping tests were conducted at a coastal fractured aquifer in Muan county, Korea, of which the drawdown data, measured at the two observation wells, were used for derivative analysis. Wellbore storage and transition period were hard to identify at conventional log-log and semi long plots, but was easily recognized by distinctive curves of positive unit slope, hump and negative unit slope in the derivative plot. For the observation well of OW-2 at which wellbore storage and transition lasted over an hour, conventional aquifer analysis would suffer from the uniqueness problems and in further result in erroneous hydraulic parameters. Derivative analysis was found to be effective for distinguishing the drawdown data directly reflecting the aquifer property from those reflecting non aquifer effects such as wellbore storage and transition, which offers a unified methodology to yield correct hydraulic parameters from aquifer test data.

예천온천지구내 온천공간 수위간섭을 고려한 적정양수량 평가 (The Evaluation of Safe Yield Considered Interference Drawdown between Hot Spring Wells at Yecheon Hot Spring Area)

  • 이철우
    • 지질공학
    • /
    • 제17권3호
    • /
    • pp.405-409
    • /
    • 2007
  • 예천온천지구에는 5개 온천공이 개발되어 있으며, 온천공들간의 거리는 약 $159.0m{\sim}702.6m$정도이다. 온천조사시 적정양수량 평가에 있어서는 각 공에 대한 적정양수량을 평가한 후 온천공간 수위간섭을 고려하여 적정양수량을 조절하도록 되어있다. 2호공과 5호공의 공간 거리는 약 159 m로서 5개 공중 가장 가깝게 위치하고 있으며, 양수시험시 이들간의 수위간섭 현상도 매우 크게 발생하였다. 5호공에서 3일간 양수시 5호공 자체의 수위강하는 17.21 m 이었으며, 2호공의 수위강하 역시 16.67 m로 두 공간에는 약 0.54 m 정도의 차이만을 보였다. 따라서 온천공간 영향의 정도는 약 97%로 매우 높았으며, 적정양수량도 당초 $750m^3/day$에서 $24m^3/day$로 감하였다. 또한 이와 같이 두 공간에 영향이 심한 원인은 대수층이 1.5차원에 기인한 것으로 해석된다.

상주시 임곡리 굴착공의 적정양수량 결정 (Optimal Pumping Rate of a Water Well at Imgokri, Sangju City)

  • 조병욱;윤욱;문상호;이병대;조수영;김용철;황세호;신제현;하규철
    • 지질공학
    • /
    • 제27권3호
    • /
    • pp.255-265
    • /
    • 2017
  • 상주시 임곡리에 굴착된 심도 100 m 지하수공(PW-2)의 적정양수량을 산정하였다. 시추코아와, 물리검층 자료에 의하면 지하수 산출 심도는 26.1~26.5, 28.0~30.0, 33, 58, 71 m로 해석된다. 단계양수시험에 의하면 40, 55, 70, 90, $132m^3/d$의 양수량으로 70일간 양수시 수위강하량은 각각 6.48, 11.56, 18.07, 28.99, 60.26 m로 예상되었다. $117m^3/d$으로 250분간 실시한 일정량양수시험에서는 양수 경과시간 120~150분에 영향추가 불투수층 경계조건에 도달하여 급격한 수위강하가 일어나 PW-2의 한계채수량은 $90m^3/d$로 산정하였으며 이때의 수위강하량은 28.82~31.27 m이다. 적정양수량은 한계채수량의 범위내의 정류상태여야 하기 때문에 PW-2의 적정양수량은 $70{\sim}90m^3/d$로 제시하였다. 불투수층 경계조건에서 직선의 기울기가 급해지며 지하수의 DO와 ORP가 증가하는 것으로 보아 PW-2를 중심으로 한 기반암지하수의 발달은 제한적인 것으로 추정된다.

농업용 관정의 기계적 처리 이후 성능 개선 효과의 정량적 평가 사례 (Quantitative Evaluation for Improvement Effects of Performance After Mechanical Rehabilitation Treatments on Agricultural Groundwater Well)

  • 송성호;이병선;안중기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권4호
    • /
    • pp.42-49
    • /
    • 2016
  • Step-drawdown pumping tests for identifying the improvement of groundwater well performance after rehabilitation treatments were conducted in three longstanding wells. Three selective mechanical treatment methods including power bubble, high-voltage electric pulse, and air surging were applied to these wells and the applicability of these methods to secure additional groundwater resources were evaluated quantitatively. Commonly, drawdown at final stage of stepdrawdown pumping tests after rehabilitation decreased by as much as 0.61~0.70 meters compared to those before rehabilitation. In addition, final specific drawdown values of three wells increased from 9% to 14% after rehabilitation. Formation loss coefficient and well loss coefficient decreased to 6.1% and 60.6%, respectively, indicating some clogging materials by precipitation/corrosion/microbe within pores of aquifer materials, gravel packs, and screens were effectively removed by applied methods. Decrease of formation loss coefficient was higher in the well applied by the power bubble method meanwhile high-voltage electric pulse method demonstrated the higher decrease of well loss coefficient. Additionally secured groundwater amounts after rehabilitation ranged from 23.3 to 32.1 m3/day, which account for 8~16% of initially developed pumping rates of the wells. From the results of this study, the effective selection of rehabilitation treatments considering aquifer characteristics are expected to contribute to secure groundwater resources for irrigation as well as to plan systematic management program for groundwater resources in rural area.

장기 및 단계 양수시험 시 강변여과 지하수의 수질변화 특성 (Geochemical Characteristics of Groundwater during the Constant and Step-drawdown Pumping Tests at the River Bank Filtration Site)

  • 김규범;신선호;김병우;박준형
    • 한국지반환경공학회 논문집
    • /
    • 제14권8호
    • /
    • pp.11-21
    • /
    • 2013
  • 창녕군 낙동강변의 강변여과 예정 지점에서 양수시험 동안에 발생하는 지하수 내 철과 망간을 포함한 다양한 수질항목 변화를 파악하기 위한 실험을 수행하였다. 5단계의 단계양수시험($500m^3/day{\sim}900m^3/day$) 및 26시간의 장기 양수시험($800m^3/day$) 동안에 양수정과 10개의 관측정에서 지하수 시료를 채취하였다. 장기 양수시험보다는 단계양수시험 기간 동안에 이온 농도의 변화가 뚜렷하였다. 특히, 단계양수시험 동안의 철과 망간 농도의 감소는 양수지점과 대수층의 연결성이 좋아 영향반경이 작은 방향을 따라 뚜렷하게 나타났다. 양수량의 급변에 따라 지하수 흐름에 교란이 발생하고 공기 접촉 등을 통하여 용존 철과 망간의 침전 산화가 촉진되는 것으로 평가되었다. 향후 지하수 내 철과 망간 저감을 위한 효율적인 지중처리 기술 개발을 위해서는 양수정의 운영 방법, 대수층의 공간적 분포 등이 중요한 요인으로 고려되어야 한다.