• 제목/요약/키워드: Drawdown

Search Result 201, Processing Time 0.024 seconds

Physical and numerical modeling of drag load development on a model end-bearing pile

  • Shen, R.F.;Leung, C.F.;Chow, Y.K.
    • Geomechanics and Engineering
    • /
    • v.5 no.3
    • /
    • pp.195-221
    • /
    • 2013
  • A centrifuge model study is carried out to investigate the behavior of pile subject to negative skin friction induced by pile installation, ground water drawdown and surcharge loading. A single end-bearing pile is examined as the induced negative skin friction would induce the most severe stress on the pile structural material as compared to friction piles. In addition, the behavior of the pile under simultaneous negative skin friction and dead/live loads is examined. To facilitate detailed interpretations of the test results, the model setup is extensively instrumented and involves elaborate test control schemes. To further examine the phenomenon of negative skin friction on an end-bearing pile, finite element analyses were conducted. The numerical analysis is first validated against the centrifuge test data and subsequently extended to examine the effects of pile slenderness ratio, surcharge intensity and pile-soil stiffness ratio on the degree of mobilization of negative skin friction induced on the pile. Finally experimental and numerical studies are conducted to examine the effect of applied transient live load on pile subject to negative skin friction.

An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System (지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구)

  • Lim, Hyo-Jae;Kwon, Jeong-Tae;Kim, Chang-Eob;Kong, Hyoung-Jin;Park, Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

Restoration of Water Cycle by a Rainwater Management System Applied to Low Impact Development (LID) (저영향개발 (LID)을 적용한 빗물 관리 시스템에 의한 물 순환 복원)

  • Lee, Dong Chan
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.130-133
    • /
    • 2016
  • The increase in impervious surfaces due to urban development has caused a groundwater drawdown through the reduction of underground infiltration, flood disaster due to increased rainfall runoff and environmental pollution in higher pollutant concentrations of first flush rainwater. As an alternative to these problems, the needs of low impact development (LID) techniques is increasing in urban areas. In this study, the restoration efficiency of water cycle was assessed at a residential site development applied with the LID rainwater management system. The results of monitoring the water cycling showed that the efficiency of water cycle of LID rainwater management system was improved 41% more than that of conventional methods.

Fractal Model of Transient Flow in a Dual-porosity Aquifer with Constant-head Upper Boundary (일정수두 상부경계를 가지는 이중공극 대수층내 부정류에 관한 프락탈모델)

  • 함세영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 1997
  • So far, several fractal models of fluid flow in a fractured aquifer have been developed. In this study, a new fractal model is derived that considers transient flow in the dual-porosity aquifer with the fracture skin between the fissure and the block, and the storage capacity and the wellbore skin on the pumping well. Constant-head upper boundary is specified in the block. This model is a generalized one which comprises both modified Hantush equation (1960) and Boulton-Streltsova equation (1978). Type curves are plotted for different flow dimensions (0.5, 1, 1.5, 2, 2.5 and 3) with various values of the leakage factor and the fracture skin. They show dimensionless drawdown in the pumping well and observation wells located either in the fissure system or in the matrix block.

  • PDF

A Study on Seepage Characteristics in Case of Seaward Seepage Through Sea-dike (역경사 현태를 가진 방조제 성토층 단명에서의 침출현상 연구)

  • Hong, Byung-Man
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.43-51
    • /
    • 1998
  • In design and management of sea0dikes, engineers need to study various transient seepage conditions through dikes not only for the sea water infiltration into dikes due to cyclic rises of sea water level also for the seepage flow out from dikes toward the sea due to cyclic drawdown of sea water level. Characteristics of seepage flow toward the sea from dikes are more complicated than as known and remained unclearly. The case of such seepage flow may be explained by figuring out seepage characteristics in filter as a part of sea-dikes. Filters in most sea-dikes in Korea are inevitably placed with reversely inclined shape due to field construction conditions. Most computer programs for seepage analysis based on the various numerical methods give practically acceptable results, but for the case of reversely inclined section of filters any verification to apply them might be needed. In this study, large scaled model tests were executed to verify and understand seepage flow through earth-filled sea-dikes. The results from numerical analysis and model tests show some remarkable differences in pore pressure distribution under cyclic changes of see level, and some of the results need to be considered in design and construction practices with further study.

  • PDF

A Study on the Correlation between Pumping Rates and Influential Factors in Tube Wells for Irrigation (관개용 관정의 양수량과 영향인자들의 상관관계에 관한 연구)

  • 류한열;구자웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3410-3419
    • /
    • 1974
  • The purpose of this study is to find out the correlation between pumping rates and influential factors in the tube wells for irrigation through the analysis of various statistical data of the existing tube wells for irrigation and pumping tests. Statistical data of the existing tube wells for irrigation were collected from the authorities concerned, and pumping tests were carried out for twelve tube wells. The results of this study are summarized as follows: 1. The drilled tube wells are the most useful among various tube wells in securing pumping rates. 2. The enlargement of well diameter or the improvement of pumping equipments is necessary in drilled tube wells with pumping rates more than 806 ㎥/day, and the adjustment of foot valves or the special control of pumping equipments is necessary in tube wells with pumping rates less than 300 ㎥/day. 3. The choking of aquifer and slits can be prevented by removing earth and sand piled in tube wells. 4. The increase of well loss and the destruction of aquifer can be prevented by determining the optimum pumping rates through the step draw down tests. 5. The thickness of gravel packing is rather thin in drilled tube tube wells. 6. High pamping rates can be gained by deepening the depth of tube wells in the place the ground water storage is abundant, the thickness of aquifer is thick. and the depth of tube wells is deep. 7. Higher pumping rates can be obtained by constructing tube wells in the place where the drawdown is little and the coefficient of transmissibility is large.

  • PDF

Hydraulic Properties of Duksan Hot-spring Area (덕산온천 지역의 수리적 성질)

  • 함세영;조병욱;성익환
    • The Journal of Engineering Geology
    • /
    • v.9 no.2
    • /
    • pp.101-118
    • /
    • 1999
  • The pumping test analysis on 28 pumping test data in Duksan hot-spring area was performed using the fractal model, the leaky fractal model, and the steady-state dual-porosity fractal model. The fractional flow dimension 1.9 or 2.0 was determined in the central put of the hot spring and the fractional flow dimension 1.5-1.7 in the marginal area. For the flow dimension 2.0, the correlation between the transmissivity and the productivity index by the aquifer loss was much better than that between the transmissivity and the specific yield by the total drawdown. On the other hand, for the flow dimension 1.9, the correlation between the generalized transmissivity and the productivity index was very similar to that between the generalized transmissivity and the specific yield.

  • PDF

The Correlation between Groundwater Level and Moving Average of Precipitation in Nakdong River Watershed (낙동강유역의 지하수위와 강우이동평균의 상관관계)

  • Yang, Jeong-Seok;Ahn, Tae-Yeon
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.507-510
    • /
    • 2007
  • The correlation between groundwater level(GWL) and the moving average of precipitation was analyzed based on the observation data in Nakdong river watershed. The precipitation data was compared and analyzed with the GWL data from adjacent observation point to the precipitation gauge station. The correlation between the moving average of precipitation with several averaging periods and GWL were analyzed and we could choose the averaging period that produces maximum correlation. A severe drawdown was observed from December to April. The maximum correlations between GWL and the moving average of precipitation were occurred from 20-day to 80-day averaging period.

Analysis of Ground Deformation Deformation using Resistivity Monitoring Technique at a Tunnel Excavation Area (전기비저항 모니터링을 이용한 터널 주변 지반상태 변화 파악)

  • Ahn, Hee-Yoon;Jeong, Jae-Hyeung;Cho, In-Ky;Park, Sam-Gyu;Kim, Ki-Seog;Jung, Lae-Chul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.93-100
    • /
    • 2007
  • During tunnel excavation, drawdown of groundwater table or discharge from tunnel faces may not only reduce stability of tunnel and work efficiency but cause environmental problems. We have investigated the applicability of electrical resistivity survey for the establishment of the monitoring system for groundwater behavior and detecting flow channel of groundwater during tunnel excavation. The groundwater level was continuously measured at several points for 1 year. Survey was conduted at every 3 months using preinstalled electrical resistivity cables on site. The results show that observed changes in resistivity ratios in the area can be explained with observed changes in groundwater level. Thus, we believed that electrical resistivity analysed together with groundwater data can be applied for the monitoring of groundwater in tunnel area.

  • PDF

The safety behavior of agricultural reservoirs due to raising the embankment

  • Lee, Dalwon;Lee, Younghak
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.3
    • /
    • pp.243-252
    • /
    • 2013
  • This study was carried out to investigate safety evaluation of agricultural reservoirs due to raising the embankment. The seepage analysis and large-scale model test were performed to compare and analyze the pore water pressure(PWP), leakage quantity, settlement and piping phenomenon in the inclined core type and the vertical core type embankments. The PWP after raising the embankment showed smaller than before raising the embankment and the stability for piping after raising the embankment. The allowable seepage quantity and the allowable leakage for the steady state and transient conditions is within the range of safe management standard. After raising the embankment in the inclined core, there was no infiltration by leakage. For the vertical core, the PWP showed a large change by faster infiltration of pore water than in the inclined core. In a rapid drawdown, inclined core was remained stable but the vertical core showed a large change in PWP. Settlement after raising the embankment showed larger amounts of settlement than before raising the embankment. The leakage quantity before raising the embankment and the inclined core type showed no leakage. From the result, an instrument system that can accurately estimate a change of PWP shall be established for the rational maintenance and stabilization of raising the embankment for agricultural reservoirs.