• 제목/요약/키워드: Drainage performance

검색결과 232건 처리시간 0.022초

배수효율이 높은 지하암거의 간격과 주름유공관의 통수능 비교분석 (A Comparative Study on the Spacing and Discharge Performance of Subsurface Drainage Culvert to Increase Drainage Efficiency)

  • 김현태;유전용;정기열;박영준
    • 한국농공학회논문집
    • /
    • 제61권6호
    • /
    • pp.67-72
    • /
    • 2019
  • This study compared the theory of a culvert spacing and analytical results of the seepage flow for the subsurface drainage. i) If culvert spacing (Sc) is within 5 m, the unit drainage (q) is very larger; in contrast, if Sc is 5 m or more, there is very little drainage in the middle between drains. Therefore, the drain spacing should be within 5 m to ensure high drainage efficiency. ii) Since the planned culvert drainage increases linearly with the soil's permeability coefficient (k), k must be taken into account when determining the drain diameter by the planned culvert drainage. iii) As a result of analyzing the drainage performance of the absorbing culvert, the drainage performance is sufficient with the diameter of the corrugated drain pipe Dc = 50 mm at the length of the drain Lc = 100 m. iv) Therefore, if the drain spacing (Sc) is less than 5 m using the low-cost non-excavated drainage pipe method (${\Phi}50mm$ the corrugated drain pipe and fiber mat) rather than the conventional trench drain method (Sc > 10 m, Dc > 100 mm), uniform and high drainage efficiency can be ensured as well as low construction cost. v) The sub-irrigation+drainage culvert requires narrower drain spacing (Sc < 2-3 m) for irrigation. As a result of examining the condition of 35 mm in diameter (Dc) and 2~3 m in drain spacing, it is possible to apply the non-excavated drainage pipe method to the sub-irrigation+drainage culvert because drainage performance is sufficient at the drain length Lc = 50 m.

조립질 지반에서의 수평배수재 종류에 따른 배수성능 비교 (Comparisons of Drainage Performance on Coarse Grained Soils with Regard to Horizontal Drainage Type)

  • 방태완;조완제;설승환
    • 한국지반환경공학회 논문집
    • /
    • 제24권11호
    • /
    • pp.25-31
    • /
    • 2023
  • 대표적인 비탈면 배수공법인 수평배수공은 비탈면 내 간극수압을 감소시키기 위해 국내외에서 다수 활용하고 있다. 이에 따라 다양한 연구들이 선행되어 왔으나, 수평배수공의 수량을 산정하기 위한 명확한 설계기준이 없어 획일적으로 시공되고 있다. 따라서 본 논문에서는 다양한 수평배수공의 배수성능과 영향인자에 대한 메커니즘을 규명하고자 현장토를 이용하여 모형토조실험을 수행하였다. 또한, 배수재 형상이나 크기에 따른 배수성능을 비교하고자 입도분포가 다른 시료에서의 유출량 결과를 비교 및 검토하였다. 정상류 상태에서 배수실험을 확인하기 위해 유출량을 측정한 결과, 모든 시료에서 최소 3분에서 최대 15분 뒤 일정한 속도로 배수되는 것을 확인하였다. 조립질 지반에서 단일 시간당 유출되는 양(단위 유출량)으로 비교한 경우, 배수재 형상과 크기에 따른 배수효과가 상이하여 배수성능에 영향을 미치는 것을 확인하였다. 향후 세립질 지반에서의 배수 성능실험과 수량을 결정하기 위한 기초자료로 충분히 활용될 수 있을 것으로 기대된다.

콘크리트 지하구조물 누수 처리를 위한 유도배수시스템 (Drainage system for leakage treatment of cement concrete structure in underground)

  • 김동규
    • 한국터널지하공간학회 논문집
    • /
    • 제21권4호
    • /
    • pp.573-585
    • /
    • 2019
  • 본 연구의 목적은 운영 중인 콘크리트 지하구조물에서 발생하는 누수를 유도배수하기 위하여 시공성, 차수 및 유도배수 성능을 향상시킨 유도배수시스템을 제안하는 것이다. 기존 유도배수시스템에서 제기된 유도배수관의 시공성 및 누수를 개선하였다. 개선된 유도배수관을 적용한 유도배수시스템은 시공성, 차수 및 유도배수 성능에 대한 현장평가를 위하여 재래식 콘크리트 라이닝 터널에서 시험 시공되었다. 재령 3주, 6주, 9주, 11주, 14주, 17주 및 23주차에 개선된 유도배수시스템 배면에 약 1,000 ml 이상의 붉은색 물을 주입하여 유도배수시스템의 차수와 유도배수 성능을 평가하였다. 현장 성능평가 실험이 진행된 6개월 동안 터널이 위치한 지역의 일일 평균 온도는 $-12.4{\sim}19.7^{\circ}C$이며 일일 최저 온도는 $-17.2^{\circ}C$이고 일일 최고 온도는 $26.7^{\circ}C$였다. 현장 성능평가 실험이 진행되는 6개월 동안 개선된 유도배수시스템에서는 누수가 발생하지 않았다. 또한 개선된 유도배수관에서도 누수가 발생하지 않았다. 개선된 유도배수시스템은 누수가 발생하는 다양한 콘크리트 지하구조물에서 적용가능하며 계절적 영향도 거의 받지 않는 것으로 판단되었다.

시험시공을 통한 일방향 배수필터의 성능 평가 (Evaluation of the Performance of One-way Drainage Filter by Field Test)

  • 서동욱;김현태
    • 한국농공학회논문집
    • /
    • 제54권4호
    • /
    • pp.47-53
    • /
    • 2012
  • It is needed to install a one-way drainage filter to prevent a seepage from lake or river outside of embankment and to promote a drainage from a flood inside of embankment when dikes such as lake dike, river dike, etc are constructed. However, the results of research for one-way drainage filter are insufficient. Therefore, through the field test of one-way drainage filter, this study checked a function of one-way drainage filter with a test of performance. As a result of field test, water flow in dike was blocked in the interception direction of the section that one-way drainage filter was installed, but water passed to the flow allowance direction of the section. Therefore we confirmed the function of one-way drainage filter. Seepage quantity in the flow allowance direction of the one-way drainage filter section was low as 74.6~80.5 % than that in the section without installation of filter because of a reduction effect of seepage with filter. And seepage quantity of field test was low as 64.3~90.0 % than that in results of seepage analysis because the coefficient of permeability of embankment in field is different from the results of laboratory test. In the future, more study will be needed to solve several problems which are related to fix the filter on slide, durability of filter, etc.

Performance evaluation of a subsurface drainage culvert system in converted paddy fields

  • Do, Jong Won;Park, Jongseok;Kim, Hyuntai;Lee, Kwangya;Shin, Hyungjin
    • 농업과학연구
    • /
    • 제47권2호
    • /
    • pp.263-273
    • /
    • 2020
  • With the change of the agricultural environment (increased rice production, decreased rice consumption, and rice production policies), converting paddy fields into upland fields is an increasing trend. In terms of conversion into upland fields, subsurface drainage is one of the most important factors for good field crop growth. This study evaluates the performance of a subsurface drainage culvert system in paddy fields and reclaimed lands. The obtained results are briefly summarized as follows: 1) After a comparative evaluation of several subsurface drainage culvert systems, including excavated subsurface drainage and non-excavated subsurface drainage types, type 3 (non-excavated, perforated drain pipe 50 mm, filter mat B50 cm, subsoiling 70 cm and culvert spacing 5 m) shows relatively high values among four types in terms of effectiveness (subsurface discharge capability) and economic efficiency (construction cost). 2) Type 3 has proven that it is suitable for design standards of discharge capacity through field tests performed in paddy fields (three sites: Gong-geom, Gae-san, Juk-san) and reclaimed lands (two sites: Gum-ho, Mi-am). 3) In the experiment of Sesamum indicum growth according to the existence of a drainage system, Sesamum indicum growth with a subsurface drainage culvert system had good value in terms of plant shoot and root length, shoot fresh and dry weight, and root fresh and dry weight).

Advanced Retention and Drainage Technology Offers Improved Performance and Operational Cost Savings

  • Freeman William L.
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.239-243
    • /
    • 2006
  • Papermaking has changed remarkably during the past 20 years, creating huge pressures on retention and drainage programs. During this time, technology has advanced from single PAM flocculants to inorganic microparticle-based programs and then to micropolymer-based programs. In today's evolving fine paper market, retention and drainage programs have to meet increased demands in many areas, such as increased speed, GAP formers, dilution headboxes, higher ash levels, reduced furnish quality, lower cost, and increased machine efficiency. Hercules recently introduced a new technology that offers performance and stability improvements and operational cost savings as compared to existing advanced technologies. $PerForm(R)$ SP Advanced Retention and Drainage Technology consists of a family of products based on a structured organic particulate that offers papermakers the ultimate flexibility for management of wet end chemistry. This paper compares $PerForm(R)$ SP Advanced Retention and Drainage Technology to inorganic microparticle and micropolymer technologies and provides multiple case histories on machines that demonstrate the benefits of the technology. In these case histories, the PerForm SP is shown to provide improved retention and drainage that results in improved performance and operational cost savings to the mill.

  • PDF

실내 모형토조실험에 의한 손상도별 수평배수공 유출량 측정을 통한 배수성능 평가 기준 제안 (A Study on the Evaluation Criteria of Drainage Performance by Measurement of Horizontal Drainage Flow Rate by Damage Degree by Interior Model Construction Experiment)

  • 최수환;이동혁;심정훈
    • 한국지반환경공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.45-50
    • /
    • 2023
  • 강우에 의한 비탈면 재해를 방지하기 위해서는 신속히 강우를 배제하는 것이 매우 중요하다. 국내에서는 지하수위를 낮추기 위한 방법으로 경제성과 시공성이 뛰어나고, 배수 성능이 좋은 수평배수공을 보편적으로 적용하고 있다. 그러나 현장에서 시공되는 수평배수공의 경우 다른 용수의 유무나 지반의 조건과 관계없이 획일적으로 시공되는 경우가 많으며, 유지관리가 원활하게 이루어지지 않고 있어 수평배수공의 배수 성능을 기대하기 힘든 경우가 많다. 이에 본 연구에서는 모형토조를 이용해 인공지반을 조성하여 수평배수공 실험을 수행하였다. 수평배수공 배수 면적을 일정량 통제해 통제면적 0%, 25%, 50%, 75% 상태의 수평배수공 유출량을 측정하였으며, 측정값과 설계 도서 등을 바탕으로 수평배수공을 정량적으로 평가할 수 있는 평가표(안)를 제안하여 현장적용이 가능한 기초자료로서 제안하고자 한다.

수치해석을 이용한 비탈면 수평배수공의 성능 분석 (Performance of Horizontal Drainage in the Slope Using Numerical Analysis)

  • 김상윤;반호기
    • 한국지반환경공학회 논문집
    • /
    • 제25권8호
    • /
    • pp.5-11
    • /
    • 2024
  • 우리나라 국토 특성 상 국토 면적에 산지가 차지하는 비율이 높고 연간 호우 발생이 하절기에 집중됨에 따라 강우로 인한 비탈면 안정성 저하가 우려된다. 이에 대비하고자 비탈면에 배수시설을 설치하여 지반 침투수에 의한 지하수위 상승을 낮춰 비탈면 안정성을 증대시킬 수 있다. 하지만 배수시설 중 수평배수공은 부대시설로 분류되어 설치 기준과 관련 연구가 부족한 실정이다. 본 연구에서는 상용지반해석 프로그램인 Plaxis-2D를 이용하여 수평배수공의 배수성능에 영향을 미치는 요소들을 검토하여 수평배수공의 길이, 설치 각도 등의 경계조건에 따른 수평배수공의 배수성능을 수치해석적으로 분석하였다. 수평배수공을 미설치한 지반보다 수평배수공을 설치한 지반에서 안전율이 높음을 확인하였으며, 수평배수공이 위치한 지반의 투수계수를 높여 수평배수공을 모사한 경우와 기존 모사방식인 Drain 기능을 활용한 경우에서의 안전율을 비교하였다. 지반투수계수를 6배 높였을 때의 안전율이 Drain 기능을 활용한 경우와 일치하여, 지반 투수계수를 6배 높여 수평배수공을 모사한 경우를 Drain 기능의 대안으로 판단하고 투수성능을 확인하였다. 비교 결과, 수평배수공의 배수성능에 있어서 설치각도보다 설치길이가 더 원활한 배수성능을 보임을 확인하여 설치 길이가 더 주요한 요인이라고 판단하였다.

집.배수용 투수성 폴리머 콘크리트 관의 농업 수리시설물의 현장적용 (Field Application of Permeable Polymer Concrete Pipe for Drainage)

  • 민정기;연규석;성찬용
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.136-143
    • /
    • 2003
  • This study is performed to evaluate performance of the developed pipe when using for underground drainage in fm land, the efficiency of the pipe is examined such as quantity of drainage, water temperature and other field performance in all weather condition. Results of this study, the higher permeability through wall of the pipe is achieved by making various size pores using open-graded aggregate. And in all weather conditions, permeable polymer concrete pipe perform much better than conventional perforated pipes. During rice farming period, quantity of drainage the permeable polymer concrete pipe is 1.25 time greater than conventional perforated pipes. Therefore, use of the permeable polymer concrete pipe is greater advantages when considering collecting and draining capacity compared with conventional perforated pipes.

운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선 (Improvement of existing drainage system for leakage treatment in exiting underground structures)

  • 김동규;임민진
    • 한국터널지하공간학회 논문집
    • /
    • 제19권4호
    • /
    • pp.669-683
    • /
    • 2017
  • 본 연구의 목적은 지하 콘크리트 구조물에서 부분적으로 발생하는 누수를 처리하기 위하여 기존에 제안된 전단면 유도배수시스템을 수정하여 제안하는 것이다. 누수된 부분에만 유도배수시스템을 적용하기 위하여 누수된 지하수를 유도배수시스템내에서 집수 지점으로 유도하는 기술과 집수된 지하수를 지하 콘크리트 구조물의 배수 시설로 이동시키기 위한 기술을 추가 제안하였다. 유도배수시스템내로 누수된 지하수를 집수 지점으로 유도하기 위한 4가지 방수 재료들, 즉, 다공질의 고무 재료인 Durkflex, 초강력 접착력을 가진 KE-45 실리콘 접착제, 폴리머 계열 재료인 Hotty-gel 및 일반 실리콘 접착제에 대한 성능 평가를 수행하였다. 방수 재료 Hotty-gel만 완벽한 방수 성능을 보였고 나머지 3가지 방수 재료들에서는 누수가 발생하였다. 선정된 방수 재료 Hotty-gel과 집수 지점에서 배수시설로 누수된 지하수를 이동시키기 위한 배수관 및 고정 새들(saddle)을 추가한 유도배수시스템을 콘크리트 옹벽에서 시험 시공하였다. 재령 7일, 14일, 21일, 28일, 2개월, 및 3개월에 수정된 유도배수시스템 배면에 1,000 ml의 물을 주입하여 방수 성능과 유도배수 성능을 평가하였다. 재령 3개월까지 방수 성능 및 유도배수 성능에는 전혀 이상이 없는 것으로 확인되었다. 수정된 유도배수시스템의 총 공사 기간 및 공사비에 대한 평가를 위하여 표면 정리 단계, 누수 처리 단계 및 단면 복구 단계별로 기존 누수 보수 공법과 비교하였다. 작업 내용, 보수 재료, 시공 장비, 작업 시간, 작업 인원 등을 고려한 개략적인 총 공사 시간 및 공사비에 대하여 비교하였다. 각 시공 단계별로 비교 분석한 결과 수정된 유도배수시스템은 기존의 누수 처리 공법보다 총 공사 기간 및 공사비를 절감할 수 있을 것으로 판단되었다.