• Title/Summary/Keyword: Drain Rate

Search Result 187, Processing Time 0.022 seconds

ELECTRICAL CHARACTERISTICS OF ORGANIC THIN FILM TRANSISTORS USING FLEXIBLE SUBSTRATE (Flexible한 기판을 사용한 유기 박막 트랜지스터의 전기적 특성 연구)

  • Lee, Jong-Hyuk;Kang, Chang-Heon;Hong, Sung-Jin;Kwak, Yun-Hee;Choi, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1590-1592
    • /
    • 2002
  • In this work the electrical characteristics of organic TFTs using organic insulator and flexible polyester substrate have been investigated. Pentacene and PVP(polyvinylphenol) are used as an active semiconducting layer and dielectric layer respectively. Pentacene was thermally evaporated in vacuum at a pressure of about $1{\times}10^{-6}$ Torr and at a deposition rate of $0.5{\AA}$/sec, and PVP was spin-coated. Aluminium and gold were used for gate and source/drain electrodes. 0.1mm thick flexible polyester substrate was used instead of glass or silicon wafer.

  • PDF

Three-Dimensional Analysis of Self-Heating Effects in SOI Device (SOI 소자 셀프-히팅 효과의 3차원적 해석)

  • 이준하;이흥주
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.4
    • /
    • pp.29-32
    • /
    • 2004
  • Fully depleted Silicon-on-Insulator (FD-SOI) devices lead to better electrical characteristics than bulk CMOS devices. However, the presence of a thin top silicon layer and a buried SiO2 layer causes self-heating due to the low thermal conductivity of the buried oxide. The electrical characteristics of FDSOI devices strongly depend on the path of heat dissipation. In this paper, we present a new three-dimensional (3-D) analysis technique for the self-heating effect of the finger-type and bar-type transistors. The 3-D analysis results show that the drain current of the finger-type transistor is 14.7% smaller than that of the bar-type transistor due to the 3-D self-heating effect. We have learned that the rate of current degradation increases significantly when the width of a transistor is smaller that a critical value in a finger-type layout. The current degradation fro the 3-D structures of the finger-type and bar-type transistors is investigated and the design issues are also discussed.

  • PDF

Performance Evaluation of the WiMAX Network under a Complete Partitioned User Group with a Traffic Shaping Algorithm

  • Akhter, Jesmin;Islam, Md. Imdadul;Amin, M.R.
    • Journal of Information Processing Systems
    • /
    • v.10 no.4
    • /
    • pp.568-580
    • /
    • 2014
  • To enhance the utilization of the traffic channels of a network (instead of allocating radio channel to an individual user), a channel or a group of channels are allocated to a user group. The idea behind this is the statistical distribution of traffic arrival rates and the service time for an individual user or a group of users. In this paper, we derive the blocking probability and throughput of a subscriber station of Worldwide Interoperability for Microwave Access (WiMAX) by considering both the connection level and packet-level traffic under a complete partition scheme. The main contribution of the paper is to incorporate the traffic shaping scheme onto the incoming turbulent traffic. Hence, we have also analyzed the impact of the drain rate of the buffer on the blocking probability and throughput.

Fabrication of Pentacene Thin Film Transistors and Their Electrical Characteristics (Pentacene 박막트랜지스터의 제조와 전기적 특성)

  • 김대엽;최종선;강도열;신동명;김영환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.598-601
    • /
    • 1999
  • There is currently considerable interest in the applications of conjugated polymers, oligomers and small molecules for thin-film electronic devices. Organic materials have potential advantages to be utilized as semiconductors in field effect transistor and light emitting didoes. In this study, Pentacene thin film transistors(TFTs) were fabricated on glass substrate. Aluminum and Gold wei\ulcorner used fur the gate and source/drain electrodes. Silicon dioxde was deposited as a gate insulator by PECVD and patterned by R.I.E. The semiconductor layer of pentacene was thermally evaporated in vaccum at a pressure of about 10$^{-8}$ Torr and a deposition rate 0.3$\AA$/sec. The fabricated devices exhibited the field-effect mobility as large as 0.07cm$^2$/Vs and on/off current ratio larger than 10$^{7}$

  • PDF

Seasonal Variation of Pollutant load flowing into Yeong-Il bay (영일만 유입오염부하량의 계절 변동에 관한 연구)

  • Yoon, Han-Sam;Lee, In-Cheol;Ryu, Cheong-Ro;Park, Jong-Hwa
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.100-107
    • /
    • 2002
  • This study investigates the seasonal variation and spatial distribution characteristics of pollutant load, as executing the quantity valuation of pollutant load inflowing into Yeong-Il bay from on-land including the Hyeong-san river. Annual total pollutant generating rate from Yeong-Il bay region are 202ton to BOD, 620ton to SS, 42ton to T-N, 16ton to T-P respectively, if expressly point out, pollutant generating rate from the Hyeong-san river is the greatest, which BOD ratio is 78.2%, SS 88.5%, T-N 62.5%, T-P 73.1%. As calculating Tank model with input value of daily precipitation and evaporation of 2001 year in drainage basin of the Hyeong-san river, Estimated result of the annual total river discharge effluencing from this river is $830{\times}106m^3$. As result to estimating annual total effluence rate outflowing at the rivers from each drainage basins, annual total inflow pollutant rate are BOD 10,633ton, SS 19,302ton, T-N 15,369ton, T-P 305ton. The III basin which is population congestion region of the Pohang-city drain away a good many pollutant load than the V basin including the Neang-Chun with wide drainage area. Especially, a great many T-N than T-P inflow into Yeong-Il bay. The accumulation of pollutant load effluenced from on-land will happen on at the inner coast region of Yeong-Il bay, finally we would make a prediction that the water quality will take a bad turn.

  • PDF

Determination of Proper Irrigation Scheduling for Automated Irrigation System based on Substrate Capacitance Measurement Device in Tomato Rockwool Hydroponics (토마토 암면재배에서 정전용량 측정장치를 기반으로 한 급액방법 구명)

  • Han, Dongsup;Baek, Jeonghyeon;Park, Juseong;Shin, Wonkyo;Cho, Ilhwan;Choi, Eunyoung
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.366-375
    • /
    • 2019
  • This experiment aims to determine the proper irrigation scheduling based on a whole-substrate capacitance using a newly developed device (SCMD) by comparing with the integrated solar radiation automated irrigation system (ISR) and sap flow sensor automated irrigation system (SF) for the cultivation of tomato (Solanum lycopersicum L. 'Hoyong' 'Super Doterang') during spring to winter season. For the SCMD system, irrigation was conducted every 10 minutes after the first irrigation was started until the first run-off was occurred, of which the substrate capacitance was considered to be 100%. When the capacitance threshold (CT) was reached to the target point, irrigation was re-conducted. After that, when the target drain volume (TDV) was occurred, the irrigation stopped. The irrigation volume per event for the SCMD was set to 50, 75, or 100 mL at CT 0.9 and TDV 100 mL during the spring to summer cultivation, and the CT was set to 0.65, 0.75, 0.80, or 0.90 in the winter cultivation. When the irrigation volume per event was set to 50, 75, or 100 mL, the irrigation frequency in a day was 39, 29, and 19, respectively, and the drain rate was 3.04, 9.25, and 20.18%, respectively. When the CT was set to 0.65, 0.75, or 0.90 in winter, the irrigation frequency was about 6, 7, 15 times, respectively and the drain rate was 9.9, 10.8, 35.3% respectively. The signal of stem sap flow at the beginning of irrigation starting time did not correspond to that of solar irradiance when the irrigation volume per event was set to 50 or 75 mL, compared to that of 100 mL. In winter cultivation, the stem sap flow rate and substrate volumetric water content at the CT 0.65 treatment were very low, while they were very high at CT 0.90 was high. All the integrated data suggest that the proper range of irrigation volume per event is from 75 to 100 mL under at CT 0.9 and TDV 100 mL during the spring to summer cultivation, and the proper CT seems to be higher than 0.75 and lower than 0.90 under at 75 mL of the irrigation volume per event and TDV 70 mL during the winter cultivation. It is going to be necessary to investigate the relationship between capacitance value and substrate volumetric water content by determining the correction coefficient.

Effect of Fibrin Sealant in Extended Lattisimus Dorsi Flap Donor Site: Retrospective Study (확장 광배근 피판거상 시 공여부 장액종의 예방을 위한 피브린 실란트의 효과에 대한 후향적 연구)

  • Cho, Hyun Woo;Lew, Dae Hyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.267-272
    • /
    • 2008
  • Purpose: Donor site seroma is the most common complication of extended latissimus dorsi flap for breast reconstruction. One of preventive treatments is to use the fibrin sealant in donor site before closure. Experimentally, it has been used successfully in the prevention of latissimus donor site seroma, but its clinical efficacy and results were very controversial. Thus, the purpose of this study is to evaluate the clinical efficacy and to determine the optimal dose of fibrin sealant. Methods: A retrospective study was done of patients operated under same surgical conditions by one operator with variable doses of fibrin sealant. The study group consisted of 60 consecutive patients who underwent breast reconstruction with extended latissimus flap reconstructions from January 2005 to December 2006. Patients were divided into 4 group by applied fibrin sealant amount(group 1=0 mL, group 2=1 mL, group 3=2 mL, group 4=4 mL). Retrospective data were obtained from total postoperative drainage amount, time from surgery to drain removal, and incidence and quantity of seroma formation in matched patients group. Results: Total drainage amount decreased relative to the amount of fibrin sealant. The seroma formation rate of 30% in the study group 4 was significantly less than group 1 rate of 71%(p<0.05). It was an improvement over the rates of as much as 79% described previously in the literature. Also, time from surgery to drain removal was shortened significantly in group 4 patients(p<0.05). Conclusion: The use of fibrin sealant in the extended latissimus dorsi flap donor site appears effective in preventing seroma. However, important factors to obtain lower seroma formation rates are proper techniques and proper amounts such as the authors suggested amount: $0.01mL/cm^2$ with spray type fibrin sealant.

Physicochemical Changes in Pork Loins Affected by Different Cooking Methods (조리방법에 따른 돼지고기 등심의 이화학적 특성 변화)

  • Yang, Jong-Beom;Ko, Myung-Soo;Moon, Yoon-Hee
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.534-540
    • /
    • 2009
  • To decrease human intake of animal fats, changes in the physicochemical characteristics of pork loins prepared by different cooking methods (boiling, steaming, baking, and frying) were investigated. The moisture content of the cooked meat decreased with all methods, and the crude lipid content decreased with all methods except frying. The cooking loss and the moisture drain rate of the cooked meats were greatest during frying, whereas the lipid drain rate was greatest with steaming. The pH value increased during all cooking processes tested. The acid value and refraction index of meat fat markedly increased by steaming and frying, respectively. The hardness, gumminess, chewiness, and cohesiveness of the meat increased notably during frying. The springiness decreased by both boiling and steaming, but rarely by baking or frying. The CIE $L^{\ast}$ (lightness) value markedly increased by both boiling and steaming, and the CIE $a^{\ast}$ (redness) value decreased notably during both boiling and steaming. The CIE $b^{\ast}$ (yellowness) value increased by both baking and frying, but usually did not increase with either boiling or steaming. The composition of fatty acids was not significantly affected by any cooking methods except frying.

Thoracic Duct Embolization for Treatment of Chyle Leakage After Thyroidectomy and Neck Dissection

  • Sungmo Moon;Juil Park;Gyoung Min Kim;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Hyung Cheol Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.55-61
    • /
    • 2024
  • Objective: This study aimed to evaluate the safety and efficacy of intranodal lymphangiography and thoracic duct embolization (TDE) for chyle leakage (CL) after thyroid surgery. Materials and Methods: Fourteen patients who underwent intranodal lymphangiography and TDE for CL after thyroid surgery were included in this retrospective study. Among the 14 patients, 13 underwent bilateral total thyroidectomy with neck dissection (central compartment neck dissection [CCND], n = 13; left modified radical neck dissection (MRND), n = 11; bilateral MRND, n = 2), and one patient underwent left hemithyroidectomy with CCND. Ten patients (76.9%) had high-output CL (> 500 mL/d). Before the procedure, surgical intervention was attempted in three patients (thoracic duct ligation, n = 1; lymphatic leakage site ligation, n = 2). Lymphangiographic findings, technical and clinical successes, and complications were analyzed. Technical success was defined as the successful embolization of the thoracic duct after access to the lymphatic duct via the transabdominal route. Clinical success was defined as the resolution of CL or surgical drain removal. Results: On lymphangiography, ethiodized oil leakage near the surgical bed was identified in 12 of 14 patients (85.7%). The technical success rate of TDE was 78.6% (11/14). Transabdominal antegrade access was not feasible due to the inability to visualize the identifiable cisterna chyli or a prominent lumbar lymphatic duct. Among patients who underwent a technically successful TDE, the clinical success rate was 90.1% (10/11). The median time from the procedure to drain removal was 3 days (with a range of 1-13 days) for the 13 patients who underwent surgical drainage. No CL recurrence was observed during the follow-up period (ranging from 2-44 months; median, 8 months). There were no complications, except for one case of chylothorax that developed after TDE. Conclusion: TDE appears to be a safe and effective minimally invasive treatment option for CL after thyroid surgery, with acceptable technical and clinical success rates.

Estimation of the Removal Capacity for Cadmium and Calculation of Minimum Reaction Time of BOF Slag (제강슬래그의 카드뮴 제거능 평가 및 필요반응시간 결정)

  • Lee, Gwang-Hun;Kim, Eun-Hyup;Park, Jun-Boum;Oh, Myoung-Hak
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.5-12
    • /
    • 2011
  • This study was focused on the reactivity of furnace slag against cadmium to design the vertical drain method with reactive column for improving contaminated sea shore sediment. The kinetic sorption test was performed by changing the initial concentration and pH. Using pseudo-second-order model, the reactivity of furnace slag was quantitatively analyzed. Equilibrium removal amount ($q_e$) of furnace slag increased and rate constant ($k_2$) decreased with the increase of initial cadmium concentration. With the increase of pH, the equilibrium removal amount ($q_e$) and rate constant ($k_2$) increased in the same initial concentration. Required retention time was related to the inverse of the product of the equilibrium removal amount ($q_e$) multiplied by rate constant ($k_2$). The required retention time could be used to design the length of reactive column.