• 제목/요약/키워드: Down-scaled model test

검색결과 47건 처리시간 0.031초

수력 현대화 개·대체 시 스파이럴 케이스와 흡출관 형상에 따른 모델수차 설계 적용사례 연구 (Study of a Model Turbine Design Case Via Application of Spiral Case and Draft Tube Shape in Hydraulic Power Plant Modernization)

  • 박노현;김진혁;김승준;현정재;최종웅;조용
    • 신재생에너지
    • /
    • 제16권2호
    • /
    • pp.35-46
    • /
    • 2020
  • Recently, turbines operating in hydro power plants are required to undergo renovation and modernization due to their age exceeding 30 years. In the process of renovation or modernization, a performance test of the scaled-down model is necessary to verify the performance of the real-size model. This model test method, with criteria that is similar to that of a real turbine, is the most economical and important method. Furthermore, the shapes of the runner and guide vane can be modified or replaced easily. However, during the process of modernization, the components with the spiral casing and draft tube are impossible to repair or replace because of the buried ground. Thus, in this study, numerical analysis is conducted to investigate the hydraulic performance based on the difference between the two-dimensional computer-aided design (CAD) shape and the real three-dimensional scan shape of the spiral casing and draft tube.

DYNAMIC CHARACTERISTICS OF SCALED-DOWN W-BEAMS UNDER IMPACT

  • Hui, T.-Y.-J.;Ruan, H.-H.;Yu, T.-X.
    • International Journal of Automotive Technology
    • /
    • 제4권1호
    • /
    • pp.31-40
    • /
    • 2003
  • W-beam guardrail system has been the most popular roadside safety device around the world. Through large plastic deformation and corresponding energy dissipation, a W-beam guardrail system contains and re-directs out-of-control vehicles so as to reduce the impact damage on the vehicle occupants and the vehicles themselves. In this paper, our recent experiments on 1 : 3.75 downscaled W-beam and the beam-post system are reported. The static and impact test results on the load characteristics, the global response and the local cross-sectional distortion are reveled. The effects of three different end-boundary conditions for the beam-only testing are examined. It is found that the load characteristics are much dependent on the combined contribution of the local cross-sectional distortion and the end-supporting conditions. The energy Partitioning between the beam and the supporting Posts in the beam-Post-system testing were also examined. The results showed that the energy dissipation partitioning changed with the input impact energy. Finally, a simple mass-spring model is developed to assess the dynamic response of a W-beam guardrail system in response to an impact loading. The model's prediction agrees well with the experimental results.

Experimental evaluation of the active tension bolt

  • Kim, Sang-Hwan;Song, Ki-Il;Park, Jae-Hyun
    • Geomechanics and Engineering
    • /
    • 제11권2호
    • /
    • pp.177-195
    • /
    • 2016
  • To secure the stability of geotechnical infrastructures and minimize failures during the construction process, a number of support systems have been introduced in the last several decades. In particular, stabilization methods using steel bars have been widely used in the field of geotechnical engineering. Rock bolt system is representative support system using steel bars. Pre-stressing has been applied to enhance reinforcement performance but can be released because of the failure of head or anchor sections. To overcome this deficiency, this paper proposes an innovative support system that can actively reinforce the weak ground along the whole structural element by introducing an active tension bolt containing a spring unit to the middle of the steel bar to increase its reinforcement capacity. In addition, the paper presents the support mechanism of the active tension bolt based on a theoretical study and employs an experimental study to validate the performance of the proposed active tension bolt based on a down-scaled model. To examine the feasibility of the active tension unit in a pillar, the paper considers a pullout test and a small-scale experimental model. The experimental results suggest the active tension bolt to be an effective support system for pillar reinforcement.

연소실에서 1/4파장 공명기의 주파수 동조에 대한 수치적 연구 (A Numerical Study on Acoustic Tuning of Quarter-Wave Resonators in a Model Combustion Chamber)

  • 박주현;박이선;손채훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2009
  • 로켓엔진 연소기의 연소 불안정 억제를 위해 연소 상황에서의 1/4파장 공명기의 주파수 동조를 수치적으로 연구하였다. 상온 음향 시험을 통해 도출된 최적 감쇠 조건을 충족시키는 사양의 1/4파장 공명기를 채택하였다. 먼저, 실규모 연소실의 조건을 모사한 모형 연소실에서의 연소장을 수치해석하여 기본 음향파 응답 특성을 분석하였다. 다음으로, 이 연소실에 음향 공명기를 장착하여 공명기 내부 물성치를 예측하였다. 이러한 기본 데이터를 토대로 특정 음향 모드를 감쇠시킬 수 있는 주파수 동조 방안을 연구하였다. 각 공명기 내부의 물성치를 토대로 공명기를 개별 공명기의 최적 동조 길이로 설계할 경우에 충분한 감쇠 성능을 얻을 수 있었다. 설계의 편의를 위해 모든 공명기를 동일길이로 설정한 경우, 길이에 따른 감쇠성능을 비교하여 제시하였다. 이를 토대로 최적의 동조길이를 찾을 수 있었다.

  • PDF

NREL 5 MW 풍력터빈 모형의 후류 유동장에 대한 실험적 연구 (An Experimental Study on Wake Flow-Field of NREL 5 MW Wind Turbine Model)

  • 강승희;유기완
    • 한국항공우주학회지
    • /
    • 제45권2호
    • /
    • pp.85-91
    • /
    • 2017
  • 본 연구에서는 NREL 5 MW 해상풍력터빈 모형의 후류 유동장 분석을 위해 1/86 축소모형을 사용한 실험적 연구를 수행하였다. 정격출력 속도 11.4 m/s와 회전수 1,045 rpm 조건에서 열선풍속계를 사용하여 반경의 6배까지 후류에서 속도 결핍 및 난류도 변화를 측정하는 풍동시험을 수행하였다. 그 결과 풍력터빈의 후류에서의 속도결핍은 횡방향과 수직 방향으로는 반경의 2배 이내에서 회복됨을 볼 수 있었으며, 끝단 와류에 의한 영향은 반경의 5배 이후에는 나타나지 않음을 볼 수 있었다. 또한, 후류의 난류도는 블레이드 끝단 부근에서 크게 나타나며 길이방향으로 반경 거리까지는 급격한 감소가 일어나지만 이 이후부터 반경의 6배까지 유지되었다.

Aeroelastic testing of a self-supported transmission tower under laboratory simulated tornado-like vortices

  • Ezami, Nima;El Damatty, Ashraf;Hamada, Ahmed;Hangan, Horia
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.199-213
    • /
    • 2022
  • The current study investigates the dynamic effects in the tornado-structure response of an aeroelastic self-supported lattice transmission tower model tested under laboratory simulated tornado-like vortices. The aeroelastic model is designed for a geometric scale of 1:65 and tested under scaled down tornadoes in the Wind Engineering, Energy and Environment (WindEEE) Research Institute. The simulated tornadoes have a similar length scale of 1:65 compared to the full-scale. An extensive experimental parametric study is conducted by offsetting the stationary tornado center with respect to the aeroelastic model. Such aeroelastic testing of a transmission tower under laboratory tornadoes is not reported in the literature. A multiaxial load cell is mounted underneath the base plate to measure the base shear forces and overturning moments applied to the model in three perpendicular directions. A three-axis accelerometer is mounted at the level of the second cross-arm to measure response accelerations to evaluate the natural frequencies through a free-vibration test. Radial, tangential, and axial velocity components of the tornado wind field are measured using cobra probes. Sensitivity analyses are conducted to assess the variation of the structural dynamic response associated with the location of the tornado relative to the lattice transmission tower. Three different layouts representing the change in the orientation of the tower model relative to the components of the tornado-induced loads are considered. The structural responses of the aeroelastic model in terms of base shear forces, overturning moments, and lateral accelerations are measured. The results are utilized to understand the dynamic response of self-supported transmission towers to the tornado-induced loads.

사용후 핵연료 수송용기의 수평낙하충격에 관한 연구 (A Study on the Side Drop Impact of a Nuclear Spent Fuel Shipping Cask)

  • 정성환;이영신
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.457-469
    • /
    • 1997
  • A nuclear spent fuel shipping cask is required by IAEA and domestic regulations to withstand a 9m free drop condition. In this paper, the structural analysis under the 9m side drop condition was performed to understand the dynamic impact behavior and to evaluate the safety of the cask for 7 PWR nuclear spent fuel assemblies. The analysis result was compared with the measured value of the 9m side drop test for the 1/3 scaled-down model and the accuracy of the 3D analysis was confirmed. Analysis in accordance with the diameter of impact limiters for the proto-type cask were performed. Through the analysis, the impact behaviors due to the side drop and the effects dependent on the diameter of impact limiters were grasped. Maximum stress intensities on each part of the cask were respectively calculated by using the stress evaluation program and the structural safety of the cask was finally evaluated in accordance with the regulations.

Effects of Isolation Period Difference and Beam-Column Stiffness Ratio on the Dynamic Response of Reinforced Concrete Buildings

  • Chun, Young-Soo;Hur, Moo-Won
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.439-451
    • /
    • 2015
  • This study analyzed the isolation effect for a 15-story reinforced concrete (RC) building with regard to changes in the beam-column stiffness ratio and the difference in the vibration period between the superstructure and an isolation layer in order to provide basic data that are needed to devise a framework for the design of isolated RC buildings. First, this analytical study proposes to design RC building frames by securing an isolation period that is at least 2.5 times longer than the natural vibration period of a superstructure and configuring a target isolation period that is 3.0 s or longer. To verify the proposed plan, shaking table tests were conducted on a scaled-down model of 15-story RC building installed with laminated rubber bearings. The experimental results indicate that the tested isolated structure, which complied with the proposed conditions, exhibited an almost constant response distribution, verifying that the behavior of the structure improved in terms of usability. The RC building's response to inter-story drift (which causes structural damage) was reduced by about one-third that of a non-isolated structure, thereby confirming that the safety of such a superstructure can be achieved through the building's improved seismic performance.

Experiments and MAAP4 Assessment for Core Mixture Level Depletion After Safety Injection Failure During Long-Term Cooling of a Cold Leg LB-LOCA

  • Kim, Y. S.;B. U. Bae;Park, G. C.;K. Y. Sub;Lee, U. C .
    • Nuclear Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.91-107
    • /
    • 2003
  • Since DBA(Design Basis Accidents) has been studied rather separately from SA(Severe Accidents) in the conventional nuclear reactor safety analysis, the thermal hydraulics during transition between DBA and SA has not been identified so much as each accident itself. Thus, in this study, the thermal hydraulic behavior from DBA to the commencement of SA has been experimentally and analytically investigated for the long-term cooling phase of LB-LOCA(Large-Break Loss-of-Coolant Accident). Experiments were conducted for both cases of the loop seal open and closed in an integral test loop, named as SNUF (Seoul National University Facility), which was scaled down to l/6.4 in length and 1/178 in area of the APR1400 (Advanced Power Reactor 1400MWe). The core mixture level was a main measured value since it took major role in the fuel heat-up rate, the location of fuel melting initiation and the channel blockage by melting material during SA. Experimental results were compared to MAAP4.03 to assess its model of calculating the core mixture level. MAAP4.03 overestimates the core two- phase mixture level because sweep-out and spill-over and the measures to simulate the status of loop seal are not included, which is against the conservatism. Thus, it is recommended that MAAP4.03 should be improved to simulate the thermal hydraulic phenomena, such as sweep-out, spill-over and the status of loop seal.

횡류형 터빈을 적용한 수직축 풍력발전시스템의 성능평가를 위한 실험 연구 (An Experimental Study for the Performance Analysis of a Vertical-type Wind Power Generation System with a Cross-flow Wind Turbine)

  • 조현성;정광섭;김철호
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1272-1278
    • /
    • 2014
  • 본 최근 성장하고 있는 해상 풍력의 실험연구에서 풍동시험이 수직형 횡류 풍력발전시스템의 성능을 조사하기 위해 실시되었다. 풍동의 시험 부분은 제한된 크기로 인해 실제 풍력 발전의 입구 안내 베인을 약 1/5로 축소시켰고, 터빈 임펠러의 지름을 모형 임펠러의 1/2로 감소시켰다. 임펠러 블레이드 갯수는 풍력 발전 시스템의 출력에 대한 또 다른 중요한 변수이기 때문에 8개와 16개로 변경하여 시험하였다. 실험 분석 결과, 모형 풍력 터빈의 출력 제동력은 정격 풍속 12m/s에서 블레이드 갯수가 8개 보다 16개일 때 82% 출력이 증가된 278와트로 측정되었고, 정격 제동력은 정격 작동 조건에서 3.9kW로 계산되었다.