• Title/Summary/Keyword: Doublet

Search Result 214, Processing Time 0.034 seconds

Design and Fabrication of Optical Element for Speckle Reduction in Laser Projector (레이저 프로젝터의 스페클 저감을 위한 광학 소자 설계 및 제작)

  • Lee, Jae-Yong;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • Laser projector has many advantages of high brightness, high resolution and small size, but the huge drawback of image degradation called speckle which generated by coherence of laser and roughness of surface interrupts their general use. There are many methods to reduce speckle pattern, but they need effective optical systems to realize display to the far field with huge volume. We designed speckle reduction element by using microlens with controlled curvature to reduce spatial coherence. Vibration element was also applied to reduce temporal coherence which considered response time of eye. Designed element was fabricated by simple reflow method and imprinting method. From the results, the fabricated element performed 48.33% of speckle reduction efficiency and 41.29% of optical efficiency with a single doublet lens.

Optical system design for biochip analyzer (바이오칩 분석 장비를 위한 광학 시스템 설계)

  • Bae, Soo-Jin;Kang, Uk;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2809-2811
    • /
    • 2003
  • Biochip-based diagnostic technology is an effective, time- and money-saving way of identifying Rifampin and Isoniazid resistant tuberculosis strains. In this paper, we suggest the optical system which is designed with the simple structure and has an appropriate specification for biochip analyzer including a CCD camera system. It consists of two parts with the same structure but opposite direction. each part is made by one lens, achromatic doublet and meniscus. We changed the working distance of the optical system and observed its characteristics.

  • PDF

Effective Optical System Design for Biochip Analyzer with CCD Image System (CCD image system을 갖는 유전체칩 분석장치를 위한 효율적인 광학시스템 설계)

  • Bae, Su-Jin;Gang, Uk
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.488-491
    • /
    • 2003
  • Biochip-based diagnostic technology is an effective, time- and money- saving way. But, biochip analyzer including CCD imaging system has a complete optical system. It is one of reasons that the cost of biochip analyzer is expensive with CCD imaging system. In this paper, We suggested the simple and effective optical system for biochip analyzer with CCD imaging system. It consists of two parts with the same structure but opposite direction. Each part consists of achromatic doublet and meniscus. Suggested optical system has less lenses than existing system and more efficiently.

  • PDF

Flutter Suppression of 2-D Wing/Store Model (2차원 날개/스토어 모델의 플러터 억제)

  • Bae, Jae-Sung;Kim, Do-Hyung;Yang, Seung-Man;Lee, In
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1197-1201
    • /
    • 2001
  • Flutter suppression of a wing/store model is investigated. An aircraft wing with a store is modeled as a 2-D typical section. Unsteady aerodynamics of the wing/store model are computed by using Doublet Hybrid Method(DHM) in the frequency-domain, and are approximated by Minimum-state(MS) approximation. LQG controller is used to suppress the flutter of the wing/store model and the aeroelastic characteristics of the closed-loop system are investigated. The flutter characteristics of the wing/store model are improved and the flutter speed is increased up to about 16 %.

  • PDF

Flutter Suppression of Wing/store Model (날개/스토어 모델의 플러터 억제)

  • Bae, Jae-Sung;Kim, Do-Hyung;Yang, Seung-Man;Lee, In
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.7
    • /
    • pp.493-501
    • /
    • 2002
  • Flutter suppression of a wing/store model is investigated. An aircraft wing with a store is modeled as a 2-D typical section. Unsteady aerodynamics of the wing/store model are computed by using doublet hybrid method(DHM) in the freauency-domain, and are approximated by minimumstate(MS) approximation. LQG controller is used to suppress the flutter of the wing/store model and the aeroelastic characteristics of the closed-loop system are investigated. The flutter characteristics of the wing/store model are improved and the flutter speed is increased up to about 24 %.

Paramagnetic Inversion of the Sign of the Interference Contribution to the Transverse Relaxation of the Imido Protons of the Coordinated Imidazoles in the Uniformly $^{15}N$ Labeled Cytochrome $c_3$

  • Andre Kim;Jeong, In Cheol;Sim, Yun Bo;Gang, Sin Won;Park, Jang Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.11
    • /
    • pp.1197-1201
    • /
    • 2001
  • In the spectrum of uniformly 15N labeled cytochrome c3, the relative linewidths of the doublet peaks of the 15N-coupled imido proton of the coordinated imidazole group were reversed on oxidation. This inversion was explained by the interference relaxation process between the electron-proton dipolar and 15N-1H dipolear interactions. The inversion can be used to assign the imido protons of the coordinated imidazole groups in heme proteins.

Sharp-line Electronic Spectroscopy and Ligand Field Analysis of Cr(III) Complexes with Amino Acid Ligands

  • 박성진;최영근;한승석;이규왕
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.12
    • /
    • pp.1475-1478
    • /
    • 1999
  • Ligand field calculations have been performed based on the data from the absorption and low temperature sharp-line excitation spectra of fac-Cr(gly)₃, fac-Cr(L-serine)₃ · 2H₂O and fac-Cr(L-leucine)₃·2H₂O. The optimized ligand field parameters for all complexes show that the carboxylate and the amino groups are moderate σ-donor. The values of $e_{{\pi}O}$ are typical of other complexes with carboxylate ligands. However, the π-interaction of carboxylic oxygen to the chromium in serinato complex is much weaker than that of other complexes. The inclusion of π-anisotropy is necessary to adequately explain the large doublet splittings.

Microdomain Formation in Phosphatidylethanolamine Bilayers Detected by $^2H$ NMR

  • 박장수;김앙드레;정인철;서홍숙;심윤보;강신원
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.683-688
    • /
    • 1999
  • In deuterium NMR spectra of phosphatidylethanolamine bilayers with an extremely high content of saturated fatty acids, each C1 deuteron of the glycerol backbone gave rise to a doublet. This suggests the presence of two backbone conformations, the exchange between which is slow on an NMR time scale. The origin of the two conformations has been investigated in this work using saturated 1,2-diacyl-sn-glycero-3-phosphoethanolamine specifically deuterated in the glycerol backbone. The results showed that the two conformations originate from different domains, which have different fatty acid compositions. The differential scanning calorimetry of the bilayers suggested that the size of the domain is not large enough to show an independent phase transition. Thus, the formation of microdomains in the phosphatidylethanolamine bilayers has been concluded. Conformational difference in different domains was shown to be restricted to the C1 position of the glycerol backbone. The microdomains of phosphatidylethanolamine were retained even in the presence of other phospholipids.

A Study of mixing characteristics of unlike impinging streams doublet injector (이유체 충돌 분사기의 혼합특성에 관한 연구)

  • Han, Jae-Seob;Kim, Seon-Jin;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.36-41
    • /
    • 2000
  • Mixing characteristics of unlike impinging streams double injectors have a great effect on combustion stability and combustion efficiency for liquid rocket engine. In this study a cold test was carried out, using water and TCE as simulants, in order to examine the effect of design parameters such as impingement angle, orifice diameter ratio and momentum ratio on the mass distribution and mixing quality.

  • PDF

Aerodynamic Analysis of Helicopter Rotor by Using a Time-Domain Panel Method

  • Kim, J.K.;Lee, S.W.;Cho, J.S.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.638-642
    • /
    • 2008
  • Computational methods based on the solution of the flow model are widely used for the analysis of lowspeed, inviscid, attached-flow problems. Most of such methods are based on the implementation of the internal Dirichlet boundary condition. In this paper, the time-domain panel method uses the piecewise constant source and doublet singularities. The present method utilizes the time-stepping loop to simulate the unsteady motion of the rotary wing blade. The wake geometry is calculated as part of the solution with no special treatment. To validate the results of aerodynamic characteristics, the typical blade was chosen such as, Caradonna-Tung blade and present results were compared with the experimental data and the other numerical results in the single blade condition and two blade condition. This isolated rotor blade model consisted of a two bladed rotor with untwisted, rectangular planform blade. Computed flow-field solutions were presented for various section of the blade in the hovering mode.

  • PDF