• Title/Summary/Keyword: Double-skin

Search Result 295, Processing Time 0.024 seconds

Ultimate Compressive Strength-Based Safely and Reliability Assessment of the Double Skin Upper Deck Structure (압축최종강도(壓縮最終强度)를 기준으로한 이중갑판구조(二重甲板構造)의 안전성(安全性) 및 신뢰성(信賴性) 평가(評價))

  • Jeom-K. Paik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.150-168
    • /
    • 1991
  • A practical procedure for the ultimate compressive strength-based safety and reliability assessment of the double skin upper deck structure is described. The external compressive stress acting on the upper deck structure which is due to the still water and wave-induced sagging moment is approximately estimated by using the existing rule of classification society. The ultimate compressive stress of double skin structure under the action of sagging moment is analyzed by using idealized structural unit method. Here an idealized plate element subjected to uniaxial load is formulated by idealizing the nonlinear behaviour of the actual element taking account of the initial imperfections in the form of initial deflection and welding residual stress. The interaction effect between the local and global failure in the structure is also taken into consideration. The accuracy of the present method is verified comparing with the present solution and the existing numerical and experimental results for unit member and welded box columns. The safety of the structure is evaluated using the concept of conventional central safety factor and the reliability assessment is made by using Cornel's MVFOSM method. The present procedure is then applied to upper deck structure of double skin product oil carrier. The influence of the initial imperfections and the yield stress of the material on the safety and reliability of the structure is investigated.

  • PDF

Sound Transmission Loss of Double Panels : II. Double Panels with Porous Materials (이중판의 차음손실 : II. 다공질재 이중판)

  • 강현주;이정권;김현실;김재승;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.634-642
    • /
    • 1998
  • This paper deals with the analytical model of an elastic porous material in sound transmission loss of a double panel with fiber glasses. From the parametric analysis, it is concluded that the boundary condition, which is concerned to the contact between the skin panel and core materials, does not have much influence on sound transmission loss of a double panel with fiber glasses, and material properties of the porous material become, however, important factors to mass-spring-mass resonance. The comparisons of the prediction with the measurement of sound transmission loss of walls show good agreement between the two values.

  • PDF

Tests and numerical behavior of circular concrete-filled double skin steel tubular stub columns under eccentric loads

  • Manigandan R.;Manoj Kumar
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.287-299
    • /
    • 2023
  • This article describes experimental and numerical analyses of eccentrically loaded over the axially loaded circular concrete filled double-skinned steel tubular (CFDST) short columns. Tests on circular CFDST short columns under eccentric and concentric loading were conducted to assess their responses to the frequent intensity of 5-30 mm at the interval of each 5 mm eccentric loading conditions with constant cross-sectional proportions and width-to-thickness ratios of the outside and internal tubes. The non-linear finite-element analysis of circular CFDST short columns of eccentrically loaded over the axially loaded was performed using the ABAQUS to predict the structural behavior and compare the concentric loading capacity over the various eccentric loading conditions. The comparison outcomes show that the axial compressive strength of the circular CDFST short columns was 2.38-32.86%, lesser than the concentrically loaded short column with the inner circular section. Also, the influence of computer simulation employed is more efficient in forecasting the experimentally examined performance of circular CFDST stub columns.

Reconstruction of the Maxillary and Cheek Skin Defect with Folded Latissimus Dorsi Free Flap : A Report of One Case (협부피부를 침범한 상악암에서 광범위 절제술 후 광배근 이중도서형 유리피판을 이용한 재건술 1예)

  • Kwon Yun-Hwan;Seo Kyu-Hwan;Lee Seung-Hoon;Dhong Eun-Sang;Kwon Soon-Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.20 no.1
    • /
    • pp.41-43
    • /
    • 2004
  • An advanced maxillary sinus cancer requires an extensive ablation that results an extensive facial deformity, including a skin defect. Reconstruction has to be considered in a radical maxillectomy, especially with skin defect may be accomplished in one stage with a microsurgical free transfer of a latissimus dorsi flap. A man of right maxillary sinus cancer, squamous cell carcinoma, 47 years old of age, had soft tissue invasion of the cheek region. He underwent a radical maxillectomy with extensive skin excision. The maxillectomy and skin defects were reconstructed with the double skin island latissimus dorsi myocutaneous free flap. The cosmetic result and the functional outcome of the nose were thought to be considerably satisfied.

Mild Ptosis Correction with the Stitch Method During Incisional Double Fold Formation

  • Lee, Edward Ilho;Ahn, Tae Joo
    • Archives of Plastic Surgery
    • /
    • v.41 no.1
    • /
    • pp.71-76
    • /
    • 2014
  • Background Numerous methods exist for simultaneous correction of mild blepharoptosis during double eyelid surgery. These methods are generally categorized into either incisional (open) or non-incisional (suture) methods. The incisional method is commonly used for the creation of the double eyelid crease in patients with excessive or thick skin. However, concurrent open ptosis correction is often marred by the lengthy period of intraoperative adjustment, causing more swelling, a longer recovery time, and an increased risk of postoperative complications. Methods The authors have devised a new, minimally invasive technique to alleviate mild ptosis during incisional double eyelid surgery. The anterior lamella is approached through the incisional technique for the creation of a double eyelid while the posterior lamella, including Muller's and levator muscles, is approached with the suture method for Muller's plication and ptosis correction. Results The procedure described was utilized in 28 patients from June 2012 to August 2012. Postoperative asymmetry was noted in one patient who had severe preoperative conjunctival scarring. Otherwise, ptosis was corrected as planned in the rest of the cases and all of the patients were satisfied with their postoperative appearance and experienced no complications. Conclusions Our hybrid technique combines the benefits of both the incisional and suture methods, allowing for a predictable and easily reproducible correction of blepharoptosis with an aesthetically pleasing double eyelid.

A Research on the design method of New Media Architecture in Sendai mediatheque - Based on the Sendai Mediatheque by Toyo Ito - (뉴 미디어 건축의 설계방법에 관한 고찰 - 伊東豊雄의 센다이 미디어테크를 中心으로 -)

  • 김기수;조용수
    • Korean Institute of Interior Design Journal
    • /
    • no.36
    • /
    • pp.14-21
    • /
    • 2003
  • The Propose of this research was to consider how the New Media Architecture was applied to contemporary architecture according to the analysis of the design method process of Toyo Ito. Sendai Mediatheque by Toyo Ito stands as one of the most symbolic statement In New Media architecture. The four principal architectural elements of the Mediatheque are the digital image, the continuous space, the tube, and the skin facade. The digital image express forms of communication, person-to-person and person-to-thing, and they vary according to the media utilized on each level. The three skin elements of the Mediatheque are a double skin of MPG, skin of louvers, skin of fine-floor decking. The tubes act as columns while enveloping light, air, water, electricity the passage of people, as well as the means of transferring material. The thirteen tubes of different sizes prevent the erection of wall and suggest places instead of rooms. Instead of being limited to certain specified actions in clearly defined rooms, people are free to choose places for their actions in the continuous space.

Transdermal Delivery and Analgesic Effects of Lidocaine Hydrogel by Phonophoresis (초음파를 이용한 리도카인 수용성겔의 경피흡수 및 진통효과)

  • Yang, Jae-Heon;Kim, Dae-Keun;Song, Kyung-Suk;Yun, Mi-Young;Ahn, Hyo-Cho;Kim, Young-Il;Kim, Tae-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.149-158
    • /
    • 2007
  • To investigate the permeability of lidocaine, percutaneous absorption studies were performed using excised hairless mouse skin and the penetration of lidocaine via the skin was determined. To increase the skin permeation of lidocine, the effects of $Labrasol^{(R)}$, $Labrafil^{(R)}$, $Labrafac^{(R)}$ and $Transcutol^{(R)}$ were investigated. The skin permeation of lidocaine was increased when $Labrasol^{(R)}$ and $Transcutol^{(R)}$ were used as permeation enhancer. To evaluate the influence of ultrasound, various factors such as application modes (continuous mode and pulsed mode), frequency (1.0 and 3.0 MHz) and intensity (1.0, 1.5 and 2.0 w/$cm^2$) were investigated with lidocaine hydrogel. The pronounced effect of ultrasound on the skin permeation of lidocaine was observed at all ultrasound energy levels. The influence of frequency having an effect on skin permeation rate was higher in the case of using 1 MHz, 2.0 w/$cm^2$ and continuous treatment. As the intensity of ultrasound increased, the permeation of lidocaine was accelerated. The in vivo anesthetic effects were evaluated by two aspects as mechanical threshold and electrical threshold. Six healthy volunteers consented to the randomized, double-blind, and cross-over designed study in each group. In each subject, 3 groups were adapted such as K group (ultrasound with gel base only), L group (lidocaine gel) and B group (ultrasound with lidocaine gel). In conclusion, lidocaine was potent anesthetic which could be block pain threshold effectively. And ultrasound could accelerate the skin penetration of lidocaine. The phonophoretic delivery system could be a good candidate for lidocaine as a local anaesthetic to improve the skin permeation and in vivo anaesthetic effect.

Design and Characterization of Ascorbyl Glucoside loaded Solid Lipid Nanoparticles to improve skin penetration (피부 투과 개선을 위한 고형지질나노입자내 Ascorbyl glucoside 봉입 설계 및 특성화)

  • Yeo, Sooho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.662-668
    • /
    • 2021
  • The aim of the present study was to design ascorbyl glucoside (AG) loaded solid lipid nanoparticles (SLNs) to improve skin penetration of AG. AG loaded SLNs were prepared using double emulsion method. The prepared AG loaded SLNs investigated particle characteristics (particle size, polydispersity index, zeta potential, loading capacity). Skin penetration study was carried out using SkinEthic RHE as one of the reconstructed human epidermis models. The mean particle size and zeta potential of SLNs were 172.65 - 347.19 nm and -22.90 - -41.20 mV, respectively. The loading capacity of AG loaded SLNs demonstrated that loading efficiency and loading amount were ranged from 44.18% to 57.77% and 12.83% to 16.15%, respectively. The results of penetration showed that all SLNs enhanced the skin penetration of AG and the amount of AG from SLNs were approximately 3.7 - 7.4 times higher than that from AG solution. Therefore, AG loaded SLN might be a promising topical drug delivery system.

Biologic Arthroplasty of Elbow with Free Metatarso-Phalangeal Joint Transplantation (유리 중족-족지관절 이식술을 이용한 주관절 전치환술)

  • Chung, Duke Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.2
    • /
    • pp.154-157
    • /
    • 2000
  • Author report a case of double metatarso-phalangeal joint transplantation to the elbow joint in the 31 years old female patient who have large bone defect associated with skin and soft tissue defect. The donor joints were second and third metatarso-phalangeal joint as double joint transfer fashion to enhance stability of graft. The graft based on dorsalis pedis vessel to anastomosed with radial artery of recipient site. The result is unsatisfactory because of long lasting lateral instability of reconstructed elbow joint in spite of 40 degree flexion motion and fair axial stability. We can conclude that joints from foot can not be an effective donor for biologic joint arthroplasty of elbow joint even though double metatarso-phalangeal joint were harvested.

  • PDF