• Title/Summary/Keyword: Double-Circuit

Search Result 531, Processing Time 0.022 seconds

Advanced Distance Relaying of on a Double Circuit Transmission Line (병행 2회선 송전선로의 개선된 거리계전기법)

  • Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.

Design of Switch Mechanism of Electric Contact Using Double Scotch Yoke Mechanism (이중 스카치 요크 기구를 이용한 접점 개폐 메커니즘의 설계)

  • Yang H.I.;Ahn K.Y.;Jeong K.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.804-807
    • /
    • 2005
  • In this paper, a double scotch yoke mechanism for moving simultaneously the fixed contact and moving contact of a gas circuit brake, is proposed and designed to improve the breaking characteristics of the circuit breaker. Firstly, the design parameters of the scotch yoke are kinematically determined from the desired design condition of the circuit breaker. Next, the stroke curve of the moving contact is designed by considering the design parameter and the specified opening characteristics of electric contacts. Based on the scotch yoke and stroke curve, the dynamics of the electric contacts is analyzed using ADAMS model of switch mechanism.

  • PDF

New Double-Connected Multi-Step Inverter for SVC (SVC를 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • 최세완;양승욱;김기용
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.460-463
    • /
    • 1999
  • A new multi-step voltage source inverter is proposed in this paper. The proposed scheme is composed of the double-connected 12-step inverter with an auxiliary circuit. The auxiliary circuit includes two voltage dividing capacitors, two switching devices and a low KVA autotransformer. The resultant system is shown to be a 24-step inverter suitable for large scale SVC applications in which the PWM method can not be employed. The design parameters are derived from the analysis of voltages and currents by means of switching functions. The simulation results verify the proposed concept.

  • PDF

TRV Pattern Classification and Parameter Calculation Method for Double-Frequency Synthetic Test Circuit (2중주파 합성시험회로의 TRV 패턴 분류 및 파라미터 계산 방법)

  • Lee Yong Han
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.587-589
    • /
    • 2004
  • In this paper analytical pattern classification of TRV waves created by double-frequency synthetic test circuit was proposed. According to the classified patterns of the TRV wave, calculation methods of 3 reference lines and 4 parameters characterizing the TRV wave wire proposed. These methods can be utilized to optimize test facility and to standardize test quality.

  • PDF

Double Circuit Simultaneous Fault Analysis (이중선로의 동시사고를 고려한 상정사고해석)

  • Kim, J.U.;Moon, Y.H.;Lee, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.136-138
    • /
    • 2002
  • In this paper, we propose the analysis method of the Double Circuit Simultaneous Fault. To improve the accuracy and the promptness of the coontingency analysis, we reformed the Peterson method and extended the Sherman-Morrison equation. We also used the table of trigono -metric factor of Jacobian matrix before the fault, to compute the inverse matrix needed in the loadflow calculation.

  • PDF

A Programmable CMOS Negative Resistor using Bump Circuit (Bump 회로를 이용한 Programmable CMOS Negative Resistor)

  • Song, Han-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.253-256
    • /
    • 2002
  • A programmable CMOS negative resistor has been designed and fabricated in a 0.5um double poly double metal technology. The proposed CMOS negative resistor consists of a positive feedback OTA and a bump circuit with Gaussian-like I-V curve. Measurements of the fabricated chip confirm that the proposed CMOS resistor shows various negative resistance according to control voltage.

  • PDF

Analysis on Induced Current Density Inside Human Body of Hot-Line Worker for 765kV Double Circuit Transmission Line (765 kV 2회선 송전선의 활선 작업자 인체내부 유도전류 밀도 해석)

  • Min, Suk-Won;Song, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.46-50
    • /
    • 2004
  • This paper analysed the induced current density inside human body of hot-line worker for 765kV double circuit transmission line according to locations of human body Human was modelled by several organs, which included brain, heart, lungs, liver and intestines. We applied the 3 dimensional boundary element method to calculate induced electric fields.

  • PDF

Transient Current Limiting Characteristics of Flux-Lock Type SFCL Using Double Quench (이중퀜치를 이용한 자속구속형 초전도한류기의 과도전류제한 특성)

  • Choi, Sang-Jae;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.2
    • /
    • pp.96-100
    • /
    • 2017
  • In this paper, the flux-lock type superconducting fault current limiter (SFCL) using double quench was suggested and its transient current limiting characteristics were analyzed. The suggested flux-lock type SFCL using double quench consists of two magnetically coupled windings and two $high-T_{c}$ superconducting (HTSC) elements connected in series with each winding. To analyze the transient current limiting characteristics of the flux-lock type SFCL using double quench, the short-circuit tests according to the fault angles, which affect the transient component of the fault current right after the fault occurs, were executed. From the comparative analysis for the short-circuit tests at both $0^{\circ}$ and $90^{\circ}$ fault angles, the useful transient current limiting operations of the suggested flux-lock type SFCL through the double or the single quench occurrence were confirmed.

Comparative Analysis on Magnetization Characteristics and Stored Energy of Magnetically Coupled SFCLs Using Single and Double HTSC Elements (단일·이중소자를 이용한 자기결합 초전도 한류기의 자화특성 및 누적에너지 비교분석)

  • Choi, Sang-Jae;Kim, Bo-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.2
    • /
    • pp.101-105
    • /
    • 2017
  • In this paper, the magnetization characteristics and the stored energy of magnetically coupled superconducting fault current limiter (SFCL)s using single and double high-Tc superconducting (HTSC) elements were compared. To analyze the magnetization characteristics and the stored energy, the magnetizing current and the flux linkage, which were derived from the electrical equivalent circuit of the SFCL using single and double HTSC elements, were calculated from the voltages and the current measured in the short-circuit tests. Through the comparative analysis on the magnetization characteristics and the stored energy for SFCL using sing and double HTSC elements, the magnetically coupled SFCL using double HTSC elements was shown to be more effective than the SFCL using single HTSC element from the point of view of the magnetic saturation.

Analysis of the electrostatic induction voltage and electromagnetic induction current on the Parallel Circuit in 765kV Double Circuit Transmission Line (765kV 2회선 송전선로를 765kV 및 345kV로 병행운전시 유도현상 예측)

  • Woo, J.W.;Shim, E.B.;Kwak, J.S.;Jeon, M.R.;Kim, K.I.;Kim, T.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.169-171
    • /
    • 2002
  • The western route of KEPCO's 765kV transmission line has been tentatively operating as 345kV voltage before commercial operation. After finishing the test operation of 765kV substation in 2002. KEPCO decided to operate the 765kV line for commercial operation. During the applying of 765kV voltage to the transmission line, double circuit transmission line will be operated with two voltage grades of 765kV and 345kV. Because the earthing switch is installed on both end of transmission line, we had estimated the electrostatic induction voltage and electromagnetic induction current before the line energizing in order to confirm the ratings of earthing switch. The induced voltage and current is very important for the maintenance of parallel circuit. This paper describes the simulation study of electrical phenomena such as electrostatic induction voltage from the parallel line and electromagnetic induction current from the parallel circuit. The transmission line model was developed by EMTP (Electro-Magnetic Transient Program).

  • PDF