• Title/Summary/Keyword: Double-Circuit

Search Result 531, Processing Time 0.027 seconds

The Study on the Efficient HVDC Capacity Considering Extremely Low Probability of 765kV Double Circuit Transmission Lines Trip

  • Moon, Bong-Soo;Ko, Boyung;Choi, Jin-San
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1046-1052
    • /
    • 2017
  • The load on the power grid of South Korea is expected to grow continuously until the late 2020s, and it is necessary to increase the transfer capacity from the Eastern grid to the Seoul-Gyeonggi region by reinforcing the transmission network for the electric power system to remain stable. To this end, the grid reinforcement by two bipole LCC HVDC transmission systems have been considered on account of the public acceptability and high growth of the fault current level, even though an additional 765kV system construction is more economical. Since the probability of the existing 765kV double circuit transmission line trip is extremely low, a dynamic simulation study was carried out to estimate the efficient HVDC capacity able to stabilize the transient stability by utilizing the HVDC overload capability. This paper suggests the application plan to reduce the HVDC construction capacity with ensuring the transient stability during the 765kV line trip.

A study on Secure Communication in Hyper-Chaos with SC-CNN using Embedding Method

  • Bae, Young-Chul;Kim, Ju-Wan;Song, Hag-Hyun;Kim, Yoon-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.4
    • /
    • pp.223-228
    • /
    • 2003
  • In this paper, we introduce a hyper-chaos secure communication method using hyper-chaos circuit onsist of State-Controlled Cellular Neural Network SC-CNN). We make a hyper-chaos circuit using SC-CNN with the n-double scroll or Chua's oscillator. A hyper-chaos circuit is created by applying identical n-double scroll or non-identical n-double scroll and Chua's oscillator with weak coupled method to each cell. Hyper-chaos ynchronization was achieved using GS (Generalized Synchronization) method between the transmitter and receiver about each state variable in the SC-CNN. In order to secure communication, we have synthesizing the desired information with a hyper-chaos circuit by adding the information signal to the hyper-chaos signal using the SC-CNN in the transmitter. And then, transmitting the synthesized signal to the ideal channel, we confirm secure communication by separating the information signal and the hyper-chaos signal in the receiver.

Neuron Circuit Using a Thyristor and Inter-neuron Connection with Synaptic Devices

  • Ranjan, Rajeev;Kwon, Min-Woo;Park, Jungjin;Kim, Hyungjin;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.365-373
    • /
    • 2015
  • We propose a simple and compact thyristor-based neuron circuit. The thyristor exhibits bi-stable characteristics that can mimic the action potential of the biological neuron, when it is switched between its OFF-state and ON-state with the help of assist circuit. In addition, a method of inter-neuron connection with synaptic devices is proposed, using double current mirror circuit. The circuit utilizes both short-term and long-term plasticity of the synaptic devices by flowing current through them and transferring it to the post-synaptic neuron. The double current mirror circuit is capable of shielding the pre-synaptic neuron from the post synaptic-neuron while transferring the signal through it, maintaining the synaptic conductance unaffected by the change in the input voltage of the post-synaptic neuron.

An influence on Characteristics of double resonant type high frequency inverter according to the variable capatance of the DC voltage source separated capacitor (직류 전원 분할용 커패시터의 용량변화가 복공진형 고주파 인버터의 특성에 미치는 영향)

  • 박홍일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.360-363
    • /
    • 2000
  • A half bridge type double resonant high frequency resonant inverter using PFM is described. This proposed inverter can reduce distribution of the switching current because of using the current of the serial resonant circuit to the input current of the parallel one. In the case of variable capacitance of the DC voltage source separated capacitor the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics has been evaluated in terms of switching frequency and parameters. Based on the characteristics value a method of the circuit design is proposed. The theoretical results are in good agreement with the experimental ones. In the future this proposed circuit is considerated to be useful for induction heating and discharge lamp.

  • PDF

Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF

A Study of WLAN Switch Stucture using DGS (DGS 구조를 이용한 WLAN용 스위치 구조 연구)

  • An Ka-Ram;Park Jun-Seok;Kim Hyung-Seok;Cho Hong-Goo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.295-297
    • /
    • 2004
  • A double-role double through switch with defected ground structure (DGS) is Proposed. The equivalent circuit for the proposed switch structure is derived based on equivalent circuit of newly proposed DGS unit structure. The equivalent circuit parameters of DGS unit are extracted by using the circuit analysis method The on/off operation of the proposed switch Is obtained by varying the capacitance in the ground metallic plane The experimental results show excellent insertion loss characteristic at on state and isolation characteristic at off state.

  • PDF

A study on a CMOS analog cell-library design-A CMOS on-chip current reference circuit (CMOS 아날로그 셀 라이브레이 설계에 관한 연구-CMOS 온-칩 전류 레퍼런스 회로)

  • 김민규;이승훈;임신일
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.4
    • /
    • pp.136-141
    • /
    • 1996
  • In this paper, a new CMOS on-chip current reference circit for memory, operational amplifiers, comparators, and data converters is proposed. The reference current is almost independent of temeprature and power-supply variations. In the proposed circuit, the current component with a positive temeprature coefficient cancels that with a negative temperature coefficient each other. While conventional curretn and voltage reference circuits require BiCMOS or bipolar process, the presented circuit can be integrated on a single chip with other digiral and analog circits using a standard CMOS process and an extra mask is not needed. The prototype is fabricated employing th esamsung 1.0um p-well double-poly double-metal CMOS process and the chip area is 300um${\times}$135 um. The proposed reference current circuit shows the temperature coefficient of 380 ppm/.deg. C with the temperature changes form 30$^{\circ}C$ to 80$^{\circ}C$, and the output variation of $\pm$ 1.4% with the supply voltage changes from 4.5 V to 5.5 V.

  • PDF

A Study for DPDT Switch Design with Defected Ground Structure (DGS 구조를 이용한 DPDT 스위치 설계에 관한 연구)

  • An Ka-Ram;Jeoung Myeung-Sub;Lim Jae-Bong;Cho Hong-Goo;Park Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.132-138
    • /
    • 2005
  • In this paper a DPDT(Double-Pole Double Through) switch with defected ground structure(DGS) is proposed. The equivalent circuit for the proposed switch structure is derived according to based on equivalent circuit of proposed DGS unit structure. The equivalent circuit parameters of DGS unit are extracted by using the circuit analysis method. The on/off operation of the proposed switch is obtained by varying the capacitance of the varactor diode at the defected ground plane. In the case of ON state, the insertion loss of the fabricated DPDT was shown under 1dB. And in OFF state, we found the rejection characteristic over 20dB at the designed frequency 2.45GHz. The experimental results show excellent insertion loss at on state and isolation at off state.

A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems (리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘)

  • 안용진;강상희;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF

Analysis of Induced Voltage on Telecommunication Line in Parallel Distribution System

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Lee, Soon-Jeong;Kim, Chul-Hwan;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.726-732
    • /
    • 2014
  • A current flowing through a distribution conductor produces induced voltage, which is harmful to a telecommunication line. Previous research on induced voltage has been focused on single-circuit lines in the distribution system. However, the double-circuit lines, referred to as parallel distribution lines, are widely used in distribution systems because they have significant economic and environmental advantages over single-circuit lines. Therefore, a study on the induced voltage in double-circuit lines is needed. This paper presents a method of calculating the induced voltage in a parallel distribution system using four-terminal parameters and vector analysis. The calculation method is verified by the Electromagnetic Transient Program (EMTP) simulation.