• Title/Summary/Keyword: Double standard

Search Result 621, Processing Time 0.025 seconds

Chemical Control of Sclerotinia rot in Rapeseed Double Cropping after Rice

  • Sun Kwon-Byung;Lim June-Taeg;Jung Dong-Soo;Shin Jong-Sup
    • Korean Journal of Plant Resources
    • /
    • v.19 no.3
    • /
    • pp.392-396
    • /
    • 2006
  • This study was conducted to evaluate the control effect of fungicides of sclerotinia rot control, growth characteristics, and seed yield in the cultivation of rapeseed. All fungicides treated had no effect on the growth of rapeseed. The major fungicides were mancozeb 75% WP, chlorothalonil 75% WP, dithianon 43% WP. difenoconazole 10% WP, benomyl 50% WP, and propineb 70% WP. Dry seed yield and control were increased largely with chlorothalonil 75% WP ($33g/12{\ell}$), fungicide than the other fungicides Sclerotinia rot. All fungicides had no injury with standard dosage. On the other hand all fungicides had slight injury in the double dosage level for the rapeseed.

A study on a CMOS analog cell-library design-A CMOS on-chip current reference circuit (CMOS 아날로그 셀 라이브레이 설계에 관한 연구-CMOS 온-칩 전류 레퍼런스 회로)

  • 김민규;이승훈;임신일
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.4
    • /
    • pp.136-141
    • /
    • 1996
  • In this paper, a new CMOS on-chip current reference circit for memory, operational amplifiers, comparators, and data converters is proposed. The reference current is almost independent of temeprature and power-supply variations. In the proposed circuit, the current component with a positive temeprature coefficient cancels that with a negative temperature coefficient each other. While conventional curretn and voltage reference circuits require BiCMOS or bipolar process, the presented circuit can be integrated on a single chip with other digiral and analog circits using a standard CMOS process and an extra mask is not needed. The prototype is fabricated employing th esamsung 1.0um p-well double-poly double-metal CMOS process and the chip area is 300um${\times}$135 um. The proposed reference current circuit shows the temperature coefficient of 380 ppm/.deg. C with the temperature changes form 30$^{\circ}C$ to 80$^{\circ}C$, and the output variation of $\pm$ 1.4% with the supply voltage changes from 4.5 V to 5.5 V.

  • PDF

Development of Remediation and Stabilization Technique for Low-Permeable Contaminated Soil Using Waste Materials (폐기물을 활용한 저투수성 오염토양의 정화 및 안정화 기술 개발)

  • 박상규;이기호;박준범
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.681-688
    • /
    • 2002
  • Study was peformed to develop the‘environmental double pile’for the remediation of low-permeable contaminated soil. This technique is similar in function to‘sand drain pile’But this applies recyclable oyster shell treated as waste materials to a drain material and the pile is consisted of two layers. Inner metal pile is located in center and oyster shells are filled around it. By this technology, contaminated ground water is pumped out through the oyster shell and purified by drainage, adsorption, and reaction processes. Afterwards, the grout material is injected through the inner pile for the effect of the solidification / stabilization. As a result, the concept of this technique is a development of one-step process technology. Through the test, a consolidation characteristic by radial drain is going to be evaluated and the optimum standard of this technology will be calculated.

  • PDF

Numerical Analysis on the HVAC Characteristics of Double-deck Train (2층 객차의 HVAC특성 전산해석)

  • Nam Seong-Won;Kim Hyeong-Jin
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.358-362
    • /
    • 2003
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of HVAC(Heating, Ventilating and Air-Conditioning} for double-deck train. The HVAC system is installed under the roof of carbody. In the lay-out of HVAC system, air duct must be installed to supply air to 1st and 2nd floor respectively. The standard k-epsilon turbulent models and SIMPLEC algorithm based on finite volume method are used to solve the physical HVAC model. To assure convergence, QUICK scheme for momentum equation and the first order upwind scheme for turbulent equations are used. From the results of simulation, the temperature and velocity magnitude are also distributed uniformly in the interior of passenger car.

  • PDF

Chaotic response of a double pendulum subjected to follower force (종동력을 받는 진동계의 케이오틱 거동 연구)

  • 이재영;장안배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.295-300
    • /
    • 1996
  • In this study, the dynamic instabilities of a nonlinear elastic system subjected to follower force are investigated. The two-degree-of-freedom double pendulum model with nonlinear geometry, cubic spring, and linear viscous damping is used for the study. The constant and periodic follower forces are considered. The chaotic nature of the system is identified using the standard methods, such as time histories, phase portraits, and Poincare maps, etc.. The responses are chaotic and unpredictable due to the sensitivity to initial conditions. The sensitivities to parameters, such as geometric initial imperfections, magnitude of follower force, and viscous damping, etc. is analysed. The strange attractors in Poincare map have the self-similar fractal geometry. Dynamic buckling loads are computed for various parameters, where the loads are changed drastically for the small change of parameters.

  • PDF

A kinematic analysis of the Thai boxing clinch

  • Trial, William;Wu, Tom
    • Advances in biomechanics and applications
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 2014
  • The purpose of the study was to investigate the kinematics between the double collar-tie and double underhook Thai Boxing clinching positions. Ten amateur mixed martial arts athletes executed six knee strikes for both clinching positions with their dominant limb directed towards a target. A standard two-dimensional video motion analysis was conducted, and the results showed a statistical significant difference at the hip joint angle and the angular acceleration of the knee and ankle. Within both clinching positions, there was a statistically significant correlation between the hip and knee joint angles, hip and knee angular velocities, and hip angular acceleration. Between both clinching positions, there was a statistically significant correlation at the knee joint angle, knee angular velocity, and hip angular acceleration. This study demonstrates the importance of the hip and knee joint movements in both clinching positions, which implies the applications of strength training and flexibility at these joints for sports performance and injury prevention. It is suggested that future studies analyzing the non-dominant leg are warranted to fully understand the Thai Boxing clinch.

Halo, Reversed Halo, or Both? Atypical Computed Tomography Manifestations of Coronavirus Disease (COVID-19) Pneumonia: The "Double Halo Sign"

  • Antonio Poerio;Matilde Sartoni;Giammichele Lazzari;Michele Valli;Miria Morsiani;Maurizio Zompatori
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1161-1164
    • /
    • 2020
  • The epidemic of 2019 novel coronavirus, later named as coronavirus disease (COVID-19), began in Wuhan, China in December 2019 and has spread rapidly worldwide. Early diagnosis is crucial for the management of the patients with COVID-19, but the gold standard diagnostic test for this infection, the reverse transcriptase polymerase chain reaction, has a low sensitivity and an increased turnaround time. In this scenario, chest computed tomography (CT) could play a key role for an early diagnosis of COVID-19 pneumonia. Here, we have reported a confirmed case of COVID-19 with an atypical CT presentation showing a "double halo sign," which we believe represents the pathological spectrum of this viral pneumonia.

Evaluation of Post-LOCA Long Term Cooling Performance in Korean Standard Nuclear Power Plants

  • Bang, Young-Seok;Jung, Jae-Won;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.12-24
    • /
    • 2001
  • The post-LOCA long term cooling (LTC) performance of the Korean Standard Nuclear Power Plant (KSNPP) is analyzed for both small break loss-of-coolant accidents (LOCA) and large break LOCA at cold leg. The RELAP5/MOD3.2.2 beta code is used to calculate the LTC sequences based on the LTC plan of the Korean Standard Nuclear Power Plants (KSNPP). A standard input model is developed such that LOCA and the followed LTC sequence can be calculated in a single run for both small break LOCA and large break LOCA. A spectrum of small break LOCA ranging from \ulcorner.02 to 0.5 k2 of break area and a double-ended guillotine break are analyzed. Through the code calculations, the thermal-hydraulic behavior and the boron behavior are evaluated and the effect of the important action including the safety injection tank (SIT isolation and the simultaneous injection in LTC procedure is investigated. As a result, it is found that the sufficient margin is available in avoiding the boron precipitation in the core. It is also found that a further specific condition for the SIT isolation action need to be setup and it is recommended that the early initiation of the simultaneous injection be taken for larger break LTC sequences.

  • PDF

Comparison of Algorithm & Turbulence Modelling for Calculation of Compressor Cascade Flows (압축기 익렬 유동해석을 위한 알고리즘과 난류 모델의 비교 연구)

  • 김석훈;이기수;최정열;김귀순;임진식;김유일
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.59-69
    • /
    • 2000
  • A numerical analysis based on two-dimensional, incompressible and compressible Navier-Stokes equations was carried out for double circular arc compressor cascade and the results are compared with available experimental data. The incompressible code based on SIMPLE algorithm adopts pressure weighted method and hybrid scheme for the convective terms. The compressible code with preconditioning method involves a upwind-biased scheme for the convective terms and LU-SGS scheme for temporal integration. Several turbulence models are evaluated by computing the turbulent viscous flows; Baldwin-Lomax, standard $\kappa$ -$\varepsilon$, $\kappa$ -$\varepsilon$ Lam. Bremhorst, standard $\kappa$-$\omega$, $\kappa$ -$\omega$ SST model.

  • PDF

A Study on the Comparison and Characteristics of Public Standard Housing Unit Plan before and after the Independence from the Japan Occupation (광복전후(光復前後) 공영주택(公營住宅)의 평면비교(平面比較)와 변화특성(變化特性)에 관한 연구(硏究))

  • Yoo, Jae-Woo
    • Journal of architectural history
    • /
    • v.11 no.2 s.30
    • /
    • pp.23-35
    • /
    • 2002
  • Even though there have been greate changes in the types and contents of the housing plan in Korea since the Modem age, it seems that the identity of traditional dwelling culture is still remains within it. The purpose of this study is to examine the characteristics and features in the development of the 'Public Standard' Housing Unit Plan by comparing the differences and similarities in unit plans in housings built on Japanese occupation period and those built after the period. From the study, we can conclude as follows: 1. The public standard housing unit plans on both periods have shown the common features in the composition of their physical forms in the way that the front-row area still remains the traditional housing culture and the rear-row area reflects the desires of the modem lives. The structure of the dual-row unit plan appeared in the public standard housing plan was caused by the cultural acculturation in Japanese occupation period. 2. The public standard housing unit plans, however, show the differences in the contents and meaning in units plans with the them of the Japanese housing because of the cultural differences. These differences took placed autonomously through the change of housing plans in the modern time, and have the common features such that 1) the changes in the Maru-centered plan type differ in composition from the inner-corridor plan type used Japanese housing, and 2) the composition of the open-inner spaces in the double-row housing plan reflects the single-row outer open space In the traditional housing. All of these cultural progresses in the public standard housing unit plans was took place as the result of the inner-oriented and notional circulations derived from the modernity. However, the transformed unit plans still contains the identity derived from the variation of the traditional Korean building elements such as Maru and Ondol. In other words, those are the Maru-centered and composed housing plans with juxtaposition of the inner block and the outer block. As the conclusion, though the public standard dwelling unit plan has the similarity in the physical form, it is different in the cultural Identity and meaning from the public standard plans before the independence from the Japan occupation.

  • PDF