• Title/Summary/Keyword: Double sampling

Search Result 213, Processing Time 0.026 seconds

Capacitive Readout Circuit for Tri-axes Microaccelerometer with Sub-fF Offset Calibration

  • Ouh, Hyun Kyu;Choi, Jungryoul;Lee, Jungwoo;Han, Sangyun;Kim, Sungwook;Seo, Jindeok;Lim, Kyomuk;Seok, Changho;Lim, Seunghyun;Kim, Hyunho;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • This paper presents a capacitive readout circuit for tri-axes microaccelerometer with sub-fF offset calibration capability. A charge sensitive amplifier (CSA) with correlated double sampling (CDS) and digital to equivalent capacitance converter (DECC) is proposed. The DECC is implemented using 10-bit DAC, charge transfer switches, and a charge-storing capacitor. The DECC circuit can realize the equivalent capacitance of sub-fF range with a smaller area and higher accuracy than previous offset cancelling circuit using series-connected capacitor arrays. The readout circuit and MEMS sensing element are integrated in a single package. The supply voltage and the current consumption of analog blocks are 3.3 V and $230{\mu}A$, respectively. The sensitivities of tri-axes are measured to be 3.87 mg/LSB, 3.87 mg/LSB and 3.90 mg/LSB, respectively. The offset calibration which is controlled by 10-bit DECC has a resolution of 12.4 LSB per step with high linearity. The noise levels of tri-axes are $349{\mu}g$/${\sqrt}$Hz, $341{\mu}g$/${\sqrt}$Hz and $411{\mu}g$/${\sqrt}$Hz, respectively.

Estimating Concentrations of Pesticide Residue in Soil from Pepper Plot Using the GLEAMS Model

  • Jin, So-Hyun;Yoon, Kwang-Sik;Shim, Jae-Han;Choi, Woo-Jung;Choi, Dong-Ho;Kim, Bo-Mi;Lim, Sang-Sun;Jung, Jae-Woon;Lee, Kyoung-Sook;Hong, Su-Myeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.4
    • /
    • pp.357-366
    • /
    • 2011
  • BACKGROUND: Mathematical model such as GLEAMS have been developed and successfully applied to upland fields to estimate the level of pesticide residues in soil. But, the GLEAMS model rarely applied to the Korean conditions. METHODS AND RESULTS: To evaluate pesticide transport in soil residue using the GLEAMS model from pepper plot, Alachlor, Endosulfan, Cypermethrin and Fenvalerate were applied for standard and double rate. Soil sampling was conducted and decaying patterns of pesticides were investigated. Observed climate data such as temperature and irrigation amount were used for hydrology simulation. The observed pesticide residue data of 2008 were used for parameter calibration, and validation of GLEAMS model was conducted with observed data of 2009. After calibration, the $K_{oc}$ (Organic carbon distribution coefficient) and WSHFRC (Washoff fraction) parameters were identified as key parameters. The simulated concentrations of the pesticides except Fenvalerate were sensitive to $K_{oc}$ parameter. Overall, soil residue concentrations of Alachlor, Cypermethrin and Fenvalerate were fairly simulated compared to those of Endosulfan. The applicability of the GLEAMS model was also confirmed by statistical analysis. CONCLUSION(s): GLEAMS model was eligible for evaluation of pesticide soil residue for Alachlor, Cypermethrin and Fenvalerate.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

PWM-based Integral Sliding-mode Controller for Unity Input Power Factor Operation of Indirect Matrix Converter

  • Rmili, Lazhar;Hamouda, Mahmoud;Rahmani, Salem;Blanchette, Handy Fortin;Al-Haddad, Kamal
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1048-1057
    • /
    • 2017
  • An indirect matrix converter (IMC) is a modern power generation system that enables a direct ac/ac conversion without the need for any bulky and limited lifetime electrolytic capacitor. This system also allows four-quadrant operation, generation of sinusoidal output voltage waveforms with variable frequency and amplitude, and control of input power factor. This study proposes a pulse-width modulation-based sliding-mode controller to achieve unity input-power factor operation of the IMC independently of the active power exchanged with the grid, as well as a fast dynamic response. The designed equivalent control law determines, at each sampling period, the appropriate q-axis component of the modulated input current to be injected into the grid through the LC input filter. An integral term of the error is included in the expression of the sliding surface to increase the accuracy of the control method. A double space vector modulation method is used to synthesize the direction of the space vector of the input currents as required by the sliding-mode controller and the space vectors of the target output voltages. Simulation and experimental results are provided to show the effectiveness and evaluate the performance of the proposed control method.

A Phenomenological Study on the Meaning and Essence of the Experience of Elderly Men Living Alone in Public Rental Housing (임대주택 거주 남성 독거노인의 홀로 사는 삶의 의미와 본질에 관한 현상학적 연구)

  • Kim, Seo Hyun
    • 한국노년학
    • /
    • v.38 no.4
    • /
    • pp.1015-1033
    • /
    • 2018
  • The purpose of this study was to examine the meaning and essence of the life of elderly men living alone in public rental housing. Among the phenomenological study methods, the present study used the analysis method proposed by Giorgi(2009). The study participants included 10 elderly men living alone in public rental housing who were recruited through network sampling. The research data were collected through in-depth interviews conducted twice for each person. The results showed that living alone as an elderly man is likened to standing against cold wind out in the wilderness of the world, with living alone deemed a power game between life and death. For the participants, public rental housing is a fence that separates them from the world-the final station of a wandering life. For common people, public rental housing is a stable fence, but for the participants, it is the location of a double-edged solitary life out in the wilderness where the instincts for survival and death play a tug of war. Based on the study findings, the researcher discussed and provided suggestions for psychological housing stability, the disparagement of the elderly in mass media, and countermeasures against psychological isolation.

The Study on The Participation Motivation of Dance Sports Activation in Dance Sports Club Members (댄스스포츠 활성화를 위한 동호인의 참여 동기에 관한 연구)

  • Park, Jong-Im
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.2
    • /
    • pp.97-107
    • /
    • 2020
  • This Study designed to examine the effects of participation motivation of Dance Sports Activation. The dance sports club participants were selected by systematic stratifies cluster random sampling method. The questionnaire was given to 320 members of badminton club members and engaging in the range activity from March 2019 to April 2019. After collecting the questionnaires, I exclude 20 unreliable questionnaires which were incomplete, incorrectly marked or double marked, and used 300 questionnaires for the study. The conclusion of this research was as follows: First, Participation motivation had a effect on enjoyment factor in dance sports club participants. Second, Participation motivation had a effect on exercise dependence in dance sports club participants. Third. Enjoyment factor had a effect on exercise dependence in dance sports club participants. It was concluded that participation motivation would be beneficial for enjoyment factor and exercise dependence in dance sports club participants.

The structural relationships between organizational ethical, job satisfaction and organizational citizenship behavior of private security guards (민간경비원의 조직윤리, 직무만족 및 조직시민행동의 구조적 관계)

  • Kim, Young-Hyun;Park, Kill-Jun
    • Korean Security Journal
    • /
    • no.42
    • /
    • pp.59-85
    • /
    • 2015
  • The purpose of this study is to establish the structural relationship among organizational ethical climate, job satisfaction, and organizational citizenship behavior. It was intended for the private security guards who work in the security companies in Seoul and Gyeonggi from Jan. 1st, 2014 to Apr. 1st, 2014 to achieve the purpose like this. Purposive sampling was used as the sampling method according to this and sampling of 400 persons was done. However, the samples of 372 persons were finally used in the analysis through the process to check faithless answers, double answers, and abnormal data. The collected data was analyzed according to the purpose of the study by utilizing STATA 13.0 and AMOS 17.0. And for statistic techniques, frequency analysis, descriptive analysis, multivariate normality, confirmatory factor analysis(CFA), Pearson's correlation analysis, and structural equation model analysis were carried out. The conclusion gotten from this study through the data analyses according to the methods and procedure like this is as follow: First, organizational ethical climate has found to have the positive effect on job satisfaction(Non-standard $B=1.427^{***}$). That is, it can be interpreted that organizational ethical climate positively affects superiors, fellow employees, pay, current duties, and chances of promotion. Second, job satisfaction has found not to have the significant effect on organizational citizenship behavior. That is, it can be interpreted that job satisfaction does not affect altruism, conscience, and participation behavior. Third, organizational ethical climate has found to have the positive effect on organizational citizenship behavior (Non-standard $B=.361^{***}$). That is, it can be interpreted that organizational ethical climate positively affects altruism, conscience, and participation behavior. Fourth, the relationship between organizational ethical climate and organizational citizens has found that there is no any indirect effect in the bootstrapping estimation result to establish the indirect effect of job satisfaction. Fifth, the relationship between organizational ethical climate and job satisfaction has found that there are the moderating effects in the analytical result of the moderating effects of person-organization fit. That is, the effects of organizational ethical climate on job satisfaction have found that the groups with higher person-organization fit are more positive than those with lower person-organization fit. Sixth, the relationship between job satisfaction and organizational citizenship behavior has found that there are moderating effects in the analytical result of person-organization fit. That is, the effects of job satisfaction on organizational citizenship behavior have found that the groups with higher person-organization fit are more positive than those with lower person-organization fit.

  • PDF

Sources Apportionment Estimation of Ambient PM2.5 and Identification of Combustion Sources by Using Concentration Ratios of PAHs (대기 중 PM2.5의 오염기여도 추정 및 PAHs 농도비를 이용한 연소 오염원 확인)

  • Kim, Do-Kyun;Lee, Tae-Jung;Kim, Seong-Cheon;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.5
    • /
    • pp.538-555
    • /
    • 2012
  • The purpose of this study was to understand $PM_{2.5}$ chemical characteristics on the Suwon/Yongin area and further to quantitatively estimate $PM_{2.5}$ source contributions. The $PM_{2.5}$ sampling was carried out by a high-volume air sampler at the Kyung Hee University-Global Campus from November, 2010 to October, 2011. The 40 chemical species were then analyzed by using ICP-AES(Ag, Ba, Cr, Cu, Fe, Mn, Ni, Pb, Si, Ti, V and Zn), IC ($Na^+$, $K^+$, $NH_4{^+}$, $Mg^{2+}$, $Ca^{2+}$, $NO_3{^-}$, ${SO_4}^{2-}$ and $Cl^-$), DRI/OGC (OC1, OC2, OC3, OC4, OP, EC1, EC2 and EC3) and GC-FID (acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, benzo[b]fluoranthene, benzo[a] pyrene, indeno[1,2,3-cd] pyrene, benzo[g,h,i]perylene and dibenzo[a,h,]anthracene). When applying PMF model after performing proper data treatment, a total of 10 sources was identified and their contributions were quantitatively estimated. The average contribution to $PM_{2.5}$ emitted from each source was determined as follows; 26.3% from secondary aerosol source, 15.5% from soil and road dust emission, 15.3% from vehicle emission, 15.3% from illegal biomass burning, 12.2% from incineration, 7.2% from oil combustion source, 4.9% from industrial related source, and finally 3.2% from coal combustion source. In this study we used the ratios of PAHs concentration as markers to double check whether the sources were reasonably classified or not. Finally we provided basic information on the major $PM_{2.5}$ sources in order to improve the air quality in the study area.

The Effect of Microcurrent Application on Muscle Fatigue of Pes Planus during Gait (미세전류 적용이 편평족을 가진 사람들의 보행근육 피로도에 미치는 영향)

  • Lee, Dae-Hwan;Son, Ho-Hee;Park, Soo-Jin;Kim, Jin-Sang;Kim, Kyoung
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.2
    • /
    • pp.51-62
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of microcurrent on fatigue of muscles in people who were flat-footed during gait. Methods: 10 flat-footed university students volunteered to participate in this study. 10 flat-footed subjects were divided into 2 groups, one group was experimental group of 5subjects(This group put on microcurrent induction shoes but the subjects were not able to feel the current.) and the other group was the control group of 5subjects(This group put on the general shoes which were similar in shape but microcurrent was not induced.) to perform double blind test and random sampling. Their gait muscle fatigue of 6 regions (vastus medialis, gastrocnemius, tibialis anterior, biceps femoris, erector spinae, and rectus abdominis muscle.) was measured by EMG MP150, Delsys Inc Boston, USA during walking and then they carried out the Harvard step with a platform (It was a arbitrarily made wooden platform of 100cm long, 50cm wide, 60cm high. They carried out climbing it for one second and descending it for one second by using the Metronome program, total 5minutes) for 5minutes. Right after that, the subjects walked on a treadmill at a speed of 4km/h for 10minutes and then their gait muscle fatigue of 6regions was assessed while they were walking on the ground as equally as before exercise. Results: The experimental group has resulted in lower average differences in gait muscle fatigue before and after exercise than those of the control group average 12.24Hz(P=0.009) at vastus medialis, average 8.52Hz(P=0.016) at gastrocnemius, average 9.16Hz(P=0.009) at tibialis anterior, average 8.66Hz(P=0.047) at biceps femoris, average 7.53Hz(P=0.016) at erector spinae, and average 7.80Hz(P=0.047) at rectus abdominis. All of the assessments of muscles have shown significant difference statistically. Conclusions: This result has shown that the use of micro current could decrease gait muscle fatigue of flat-footed people. It is recommended to use a microcurrent to reduce their gait muscle fatigue.

  • PDF

Effects and Safety of Minocycline Loaded Polycaprolactone for Pericoronitis (미노클린 첨부제의 지치주위염에 대한 유효성 및 안전성 평가를 위한 위약대조 이중 맹검 제3상 비교임상시험)

  • Seol, Yang-Jo;Ko, Young-Kyung;Lee, Yong-Moo;Ku, Young;Rhyu, In-Cheul;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.619-632
    • /
    • 2000
  • This clinical study was designed to determine the clinical and microbiological outcomes and safety of using minocycline loaded polycaprolactone strip for pericoronitis patients. 64 patients showing symptoms and signs of pericoronitis were enrolled according to the inclusion criteria in this double blind study. They were randomly assigned to two groups. 32 patients comprised control group and they received only polycaprolactone films in pericoronal spaces, and another 32 patients comprised experimental group and they received polycaprolactone films loaded with 30% minocycline. Informed consent was obtained from all the participants before beginning the study. At the initial visit, gingival index(GI), papillary bleeding index(PBI), amount of gingival crevicular fluid(GCF) were recorded, and microbiological sampling was done. Then, loaded or unloaded polycaprolactone film was inserted into the pericoronal spaces. No drug was prescribed excepting this film. After one week, clinical and microbiological exam was repeated. Presence of any side effects or inconveniences were checked. Chi-square test and t-test was performed to compare outcomes. At baseline, there were no significant differences in all the criteria between experimental group and control group. Experimental group showed significant improvement compared with control group both in GI(p<0.01) and PBI(p<0.01). The amount of GCF of the experimental group was significantly decreased compared with the control group(p<0.01) and baseline(p<0.01). In microbiological study, percentage of motile rod was prominently decreased in the experimental group. Also, aerobic(p<0.001), anaerobic(p<0.001) and black pigmented(p<0.01) bacteria were significantly decreased from the baseline. Furthermore, no side effects or inconveniences was reported in the experimental group. From this study, it was concluded that insertion of polycaprolactone film with 30% minocycline into the pericoronal spaces would be effective and safe treatment for pericoronitis.

  • PDF