• Title/Summary/Keyword: Double glazed window

Search Result 8, Processing Time 0.028 seconds

Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls (광기능성 창호시스템의 동절기 채광특성에 관한 목업연구)

  • Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..

Sound Insulation Performance of the Side Layered Panels in the Next Generation High Speed Train (차세대 고속철도 차량 측면 적층재의 차음성능)

  • Lee, Joong-Hyeok;Lee, Ho-Jin;Park, In-Seok;Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.457-462
    • /
    • 2011
  • The sidewall of the HEMU-400x consists of two parts. One is the multi-layered structure including aluminium extruded panel and the other is the double glazed window. When the train runs in a tunnel, the equivalent sound insulation performance of the side wall significantly influences the internal noise levels. In aspect of the sound insulation strategy, it is important to make two parts have similar performance. In this study, the intensity sound transmission loss (ITL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance of the two parts in respect of the weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy is investigated to reduce the interior noise.

  • PDF

Sound Insulation Strategy of the Side Panels in a Tilting Train (틸팅열차 측면재의 차음 전략)

  • Kim, Seockhyun;Seo, Taegun
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.33-38
    • /
    • 2011
  • In an express tilting train, side wall insulating the noise from the exterior sound source consists of two parts. One is the layered composite panel including aluminum honeycomb, glass wool and nomex honeycomb. The other is the double glazed window. In this study, sound insulation performance of the two parts is investigated by mass law and experiment. Based on ASTM E2249-02, the intensity sound transmission loss (TL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance in respect of weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy for the interior noise reduction is investigated.

  • PDF

Thermal Performance Evaluation of the Window Systems with Air-bubble Sheets (단열시트(뽁뽁이)의 종류 및 부착위치에 따른 창호의 단열성능 평가)

  • Hwang, Je;Jeong, Ah Hee;Jeon, Byung Heoun;Ahn, Young Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.463-467
    • /
    • 2015
  • The air-bubble sheet has been widely used to wrap fragile products for long-distance transportation. The further usage of the air-bubble sheet as a thermal-insulation material for the reduction of the thermal conductivities of window systems has occurred because of its low price, in addition to its thermal-conductivity properties. In this study, the thermal performances of a variety of commercial air-bubble sheets according to various applications were evaluated. The experiments were performed with single-glazed and double-glazed windows and three types of air-bubble sheets of different air volumes. U-values are used and were calculated for the determination of the thermal performances that are based on the KS F 2278. The maximum decrease of the U-value was measured as 1.092 when a sheet was attached onto the frame of single-glazed window. The square-like air-bubble sheet that contains the largest air volume shows the highest thermal-resistance value. Double layers of the air-bubble sheets show better performances than those of the single layers on both sides of the windows.

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building (오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교)

  • Jung Gun-Joo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

Sound Insulation Strategy for the Tunnel Noise in a High Speed Train (고속철도차량의 터널 소음을 위한 차음 전략)

  • Kim, Seock-Hyun;Lee, Ho-Jin;Kim, Jung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.315-322
    • /
    • 2012
  • In a tunnel, interior noise of a high speed train increases by 5dB~7dB. The reason is that the sound intensity of the acoustic field in the tunnel significantly increases by the reflected waves occurred in the closed space. Especially, the incident acoustic power largely increases on the outside of the compartment side panel and large transmission of noise is available through the side panel and the glass window. In this paper, the sound insulation strategy in the tunnel is proposed for the next generation high speed train under development. Specimens of the aluminum extruded panels, layered panels and double glazed window are manufactured and intensity transmission loss is measured according to ASTM E2249-02. Based on the measured data, problems in the sound insulation performance are diagnosed and the sound insulation strategy is reviewed on each panel and layered structures.