• 제목/요약/키워드: Double deck tunnel

검색결과 60건 처리시간 0.024초

도심지 대심도 복층터널의 내부구조물 계획 (A Design Focuses on the Internal Structure of Double-level Tunnel)

  • 박신영;정재호;조남각;신일재;심동현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1314-1321
    • /
    • 2010
  • The west express way which links south west area of the central city of Seoul has been notorious for extremely heavy traffics since its first opening in 1991(i.e. the average vehicle speed is less than 25km/h, a daily traffic is 112,000 and among them, more than 94% of the vehicles are the light vehicles). The city government recently initiated a new BTO(Build-Transfer-Operate) project as an alternative in releasing heavy traffic and a high construction cost. The proposed underground express road is the first double-level tunnel (i.e. a total length of road is 10,91km and the tunnel is 9.308km long) ever built in South Korea, while such tunnel system is not new worldwide as such A86 East tunnel in France, SMART tunnel in Malaysia, and Fuxing tunnel in China. This paper discusses major design issues regarding the internal structures such as deck slab, and secondary liner.

  • PDF

다목적 터널의 기능별 유지관리 방법에 대한 고찰 (A study on the maintenance methods of the multi-purpose double-deck tunnel)

  • 문훈기;송인철;김재원;이혜윤
    • 한국터널지하공간학회 논문집
    • /
    • 제19권1호
    • /
    • pp.83-93
    • /
    • 2017
  • 최근 지하공간의 효율적 활용을 위해 도로 및 수로 기능을 동시에 충족하는 다목적 터널의 개발에 대한 국민적 관심이 높은 상황이다. 하지만 반복적인 기능전환과 수압변화에 따른 다목적 터널의 거동 연구는 전무한 실정이다. 본 연구에서는 대심도 복층터널의 반복적인 기능 전환에 따른 취약 구간의 분석을 통해 다목적 터널의 운영 중 필요한 유지관리 항목과 운영 방향의 설정에 대한 기초검토를 수행하였다. 또한, 터널의 시공 및 운영 중 도로 및 수로의 기능전환 단계에 따른 터널의 취약 구간을 수치해석을 통하여 분석하였다. 다목적 터널의 유지관리는 기능에 따른 특성을 고려한 다양한 분석 및 복합적인 고려가 필요하며, 본 연구를 통해 다목적 터널의 유지관리 방안을 제시하였다.

복층터널 분기 기하구조에 따른 안정성 검토에 관한 연구 (A study on the stability analysis for double deck tunnel branch geometry)

  • 박우정;장남주;김기환;최창림
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.393-404
    • /
    • 2018
  • 도심지 터널에서 지하도로는 지상도로와의 연결을 위한 램프터널을 계획하게 되고 본선터널과 램프터널이 접속되는 구간에서 대단면 터널과 분기구간이 생성된다. 본선터널과 램프터널이 접속하는 근접구간에서 응력집중으로 터널의 안정성에 심각한 문제를 초래할 수 있다. 따라서 필라부의 안정성을 확보하는 것은 터널의 안정성을 좌우하는 매우 중요한 요소라 할 수 있다. 본 연구에서는 복층터널을 대상으로 본선터널, 분기부대단면 터널 단면을 계획하고, 분기부 암반 필라의 거동을 2차원 수치해석 방법으로 검토하였다. 양호한 지반조건인 암반 III등급에서 램프터널이 본선터널에 접속하는 방법을 달리하여 필라폭에 따른 지반 안정성을 평가하였으며, 안전율 1.5 이상을 확보할 수 있는 터널 필라폭을 제안하였다.

복층터널 자동 모니터 소화설비를 이용한 화재진압 실험 (Fire Suppression Test using the Automatic Monitor System for Double-Deck Tunnel)

  • 박진욱;유용호;김휘성;박병직;김양균
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.40-46
    • /
    • 2017
  • 대도심지의 교통 체증 문제로 발생되는 경제적 손실의 해결방안으로 대심도 지하도로 개발이 국내외적으로 대두되고 있으며, 이 중 일부는 시공성 및 경제성이 뛰어난 복층터널로 계획되고 있다. 그러나 복층터널은 하나의 굴착단면에 중간 슬래브를 설치하여 상 하행선으로 사용하는 특수한 구조로 인해 일반 터널보다 층고가 낮게 설치되어 터널내에서 발생되는 화재사고 및 환기 문제에 대해 비교적 취약하다. 따라서, 복층터널의 방재적 약점을 극복하기 위해서는 복층터널에 최적화된 방재 설비구축 연구가 국내에서도 체계적으로 수행되어야 한다. 본 연구에서는 복층터널 화재 안전성 향상을 위해 화재발생시 초기 화재 진압 및 확산 방지가 가능한 자동모니터 소화설비를 개발하였으며, 차량화재 진압 실험을 통해 성능시험을 수행하였다. 그 결과로부터 30 m 거리의 차량내부화재 및 10 m 거리의 엔진룸 화재에 대해 화재 확산 방지 및 진압 효과를 확인하였다.

Temporary aerodynamic countermeasures for flutter suppression of a double-deck truss girder during erection

  • Zewen Wang;Bokai Yang;Haojun Tang;Yongle Li
    • Wind and Structures
    • /
    • 제38권5호
    • /
    • pp.399-410
    • /
    • 2024
  • Long-span suspension bridges located in typhoon-prone regions face significant risks of flutter instability, particularly in girder erection. Despite the implementation of aerodynamic countermeasures designed for the service stage, the flutter stability of bridge in girder erection may not meet the required standards. Nowadays, the double-deck truss girder is increasingly common in practical engineering which exhibits different performance from the single-deck truss girder. To gain insights into the flutter performance of this girder type and determine temporary aerodynamic countermeasures for flutter suppression in girder erection, wind tunnel tests were conducted. The effects of affiliated members on the flutter performance were first examined. Subsequently, different aerodynamic countermeasures were designed and their effectiveness was tested. The results indicate that the stabilizers above and below the upper and lower decks are the most effective for the flutter stability of bridge at positive and negative angles of attack, respectively. The higher the stabilizers are, the better the effect on flutter suppression achieves. Considering the feasibility in practical engineering, a temporary stabilizer above the upper deck was considered. It is expected that the results could provide references for the aerodynamic design of double-deck truss girder during erection.

대심도 복층터널 화재연기 확산지연장치 설치간격 및 차폐율에 따른 화재연기 지연효과 연구 (A Study on the Delay Effect of Smoke Diffusion by the Installation Intervals and the Blockage Ratio of the Fire Smoke Diffusion Delay Device in a Great Depth Underground Double-Deck Tunnel)

  • 양용원;한재희;이윤택;문정주;신태균
    • 한국자원공학회지
    • /
    • 제55권6호
    • /
    • pp.596-603
    • /
    • 2018
  • 국내 도심지의 도로는 차량수요 증가 및 부도심의 발달로 교통정체가 빈번히 발생되고 있다. 이를 해결하기 위한 방안으로 대심도 복층터널 시공을 위한 설계가 계획되고 있지만 주로 소형차전용으로써 터널높이가 낮고 단면이 작아 화재발생 시 인명피해가 발생될 가능성이 높다. 따라서 본 연구에서는 대심도 복층터널의 화재 시 인명피해 발생 최소화 방안으로 화재연기 확산지연장치 개발하였으며, 확산지연장치의 효과를 극대화할 수 있는 최적 설치간격 및 차폐율을 찾기 위해 3차원 전산수치해석(CFD)을 이용하여 Case Study를 수행하였다. 수행결과 확산지연장치의 설치간격이 짧을수록 지연효과가 높아졌지만 일정거리 이상에서는 효율변화가 미비한 경향이 발견되었고, 차폐율이 클수록 화재연기 지연효과가 높아지는 경향이 나타났지만, 차폐율이 작은 경우에는 설치간격에 따른 화재연기의 지연효과의 차이는 미소한 것으로 분석되었다.

대심도 복층터널 교차로 화재연기 확산지연 방안 연구 (A study on the fire smoke diffusion delay strategy in a great depth underground double deck tunnel junction)

  • 신태균;문정주;양용원;이윤택;한재희
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.115-126
    • /
    • 2019
  • 최근 도심지 차량 정체 해소와 주변환경을 개선하기 위하여 도심지 지하공간을 활용하는 대심도 복층터널 설계 및 시공 기술개발 연구가 진행되고 있으며, 네트워크형 복층터널은 단면이 작고, 평지 하부에 시공됨에 따라 입 출구의 경사가 가파른 특징이 있는 교차로 형태를 가지며 화재발생시 화재연기가 매우 빠르게 전파되어 인명피해 발생이 우려된다. 따라서 본 연구에서는 교차로에 화재연기 확산지연장치를 설치한 경우와 미설치된 경우에 대하여 화재연기 확산지연효과를 분석하였다. 화재연기 확산지연장치를 교차로에 설치하였을 시 화재발생 후 270초까지 화재연기가 지연되었으며, 화재연기 확산지연장치의 차단면적이 커질수록 인명피해 예방에 도움이 될 것으로 분석되었다.

실대형 진동대 시험을 통한 복층터널 중간 슬래브 진동 감쇠 고무받침 내진성능 평가 (Seismic performance evaluation of middle-slab vibration damping rubber bearings in multi-layer tunnel through full-scale shaking table)

  • 장동인;박인준
    • 한국터널지하공간학회 논문집
    • /
    • 제22권4호
    • /
    • pp.337-346
    • /
    • 2020
  • 도심권의 교통 집중과 정체로 인하여 지하 공간 활용성이 필요함에 따라 지하구조물에 대한 연구가 늘어나고 있다. 그 중 복층터널은 지하구조물을 대표 할 수 있다. 복층터널은 중간슬래브를 기준으로 상, 하부 차도를 구분하여 운영하고 있다. 중간슬래브는 차량의 하중 및 지진하중에 의하여 동적거동을 한다. 특히 지진의 의한 응답특성은 하중의 크기 및 작용 메커니즘이 매우 복잡하고 이론적 접근이 어려워 실험적 연구가 필요하다. 본 연구에서는 붕괴방지 내진 1등급의 복층터널 중간슬래브에 진동 감쇠 고무받침 유무에 따른 안정성 평가를 실시하는데 목적을 두고 있다. 본 진동대 실험에서는 상사율 1/4을 적용하였으며, 모형실험에서 지반과 모형의 일체거동을 묘사하기 위하여 라이닝과 진동대판을 고정시켰으며 이를 통해서 상대거동을 최소화 하였다. 실험대상은 가상복층터널 TBM 표준단면으로 정했다. 기반암에 가해지는 지반운동 수준을 0.154 g (붕괴방지 수준 내진 1등급 인공지진파)이며 이 가속도를 최대로 하는 지진파를 진동대 입력(기반암)에 작용시켜 모형에 증폭현상을 분석하고 진동 감쇠 고무받침 유무에 따른 중간슬래브의 내진 안정성에 대해 평가 분석 하였다. 그 결과, 지진 감쇠 고무받침 유무에 따라서 지진 가속도 감쇠 효과가 최대 40% 이상 있음을 알 수 있었다.

소형차 전용 복층터널 분기부에서의 충격손실 계수 결정 연구 (A Study on the Determination of Shock Loss Coefficient on the Branch in the Double-deck Road Tunnel for Small Car)

  • 노장훈;이승준;김진
    • 터널과지하공간
    • /
    • 제27권1호
    • /
    • pp.50-57
    • /
    • 2017
  • 본 연구는 네트워크형 복층터널의 환기설계를 위하여 분기부지점에서 발생할 수 있는 충격손실에 대한 실험연구이다. 충격손실양을 결정할 수 있는 충격손실계수는 현재까지 종횡비가 일정한 원형이나 사각단면에 관한 설계값 및 이론식만이 존재하고 있다. 하지만 현재 국내에서 검토중인 복층터널이 종횡비가 약 1:3정도로 층고가 낮은 소형차 전용도로이기 때문에 본 조건에 맞는 충격손실계수의 제시가 필요하다. 이를 위하여 Reynolds 상사법칙이 적용된 약 1:23 스케일의 실험모델을 제작하여 큰 종횡비에 따른 분기부 지점 충격손실계수를 측정하였다. 연구 결과 분기부가 존재할 때 직선구간에 작용하는 충격손실 계수 와 분기부에서 작용하는 충격손실 계수 이 선행연구 되었던 설계값 및 이론식보다 2~3배 높게 측정되는 것을 확인하였다. 즉, 큰 종횡비가 충격손실계수에 미치는 영향이 크다는 것을 확인함에 따라서 네트워크형 복층터널의 환기설계 시 보다 정확한 설계값을 제시할 수 있을 것으로 기대한다.

네트워크형 복층 도로터널 확폭구간에서의 충격손실 계수 결정을 위한 수치해석 연구 (A Numerical Analysis on the Determination of Shock Loss Coefficient at Flared Intersection of Network-type Double-deck Road Tunnel)

  • 박요한;이승준;김진
    • 터널과지하공간
    • /
    • 제28권1호
    • /
    • pp.111-124
    • /
    • 2018
  • 본 연구는 전세계적으로 활발하게 기술 개발 중인 네트워크형 복층 도로터널에서의 환기 설계를 위해 새롭게 요구되는 설계인자를 분석한다. 분류 및 합류부 지점에 존재하는 확폭구간에서 단면적의 변화에 따라 발생하는 충격손실계수를 결정하기 위해 전산유체역학(CFD)를 통한 수치해석 연구를 진행하였다. 수치해석에 사용된 모델은 실제 스케일을 반영하였고 이전의 선행 연구의 충격손실계수 값과의 비교분석을 통해 그 값의 신뢰성을 확보하였다. 수치해석 연구의 결과로 단면적비의 변화에 따른 충격손실계수 값을 도출해냈고 급확대부와 급축소부 두 경우 모두 이전의 선행 연구에서 제시된 충격손실계수 값보다 높게 계산되어졌다. 이는 네트워크형 복층 도로터널의 기하학적 구조의 특성이 충격손실계수에 미치는 영향이 크다고 판단된다. 따라서 본 연구의 결과 값은 앞으로 네트워크형 복층 도로터널의 환기 설계에 있어 좀 더 정확한 설계에 도움이 될 것으로 기대된다.