Analysis of Thermodynamic Design Data for Heating of Double - Effect Solar Absorption System using LiBr - water and Ethylene Glycol Mixture (에틸렌글리콜 혼합액을 사용하고, 태양열을 보조열원으로 하는 이중효용 흡수식 시스템의 난방 특성해석)

  • Won, S.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.51-61
    • /
    • 2002
  • Analysis of thermodynamic design data of double effect solar absorption heat pump system for heating has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data. enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture (H2O: CHO ratio 10:1 by mole) by computer simulation. The obtained results, COP and mass flow ratio of the water-lithium bromide-ethylene glycol system, are compared with data for the water-Libr pair solution.

Study on resonant electron cyclotron heating by OSXB double mode conversion at the W7-X stellarator

  • Adlparvar, S.;Miraboutalebi, S.;Kiai, S.M. Sadat;Rajaee, L.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1106-1111
    • /
    • 2018
  • Electromagnetic waves potentially have been used to heat overdense nuclear fusion plasmas through a double mode conversion from ordinary to slow extraordinary and finally to Electron Bernstein Wave (EBW) modes, OSXB. This scheme is efficient and has not any plasma density limit of electron cyclotron resonance heating due to cut-off layer. The efficiency of conversion depends on the isotropic launching angles of the microwaves with the plasma parameters. In this article, a two-step mode conversions of OSXB power transmission efficiency affected by the fast extraordinary (FX) loses at upper hybrid frequency are studied. In addition, the kinetic (hot) dispersion relation of a overdense plasma in a full wave analysis of a OSXB in Wendelstein 7X (W7-X) stellarator plasma has been numerically simulated. The influence of plasma dependent parameters such as finite Larmor radius, electron thermal velocity and electron cyclotron frequency are represented.

Time Dependent Thermal Load Analysis of the Building with an Airflow Window System (공기식 집열창 시스템이 설치된 건물의 동적부하 해석)

  • Cho, S.H.;Park, S.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Thermodynamic Analysis of Double-effect Absorption Heat Pump System with New Working Pairs (작동매체에 따른 2중효용 흡수식 시스템의 성능해석)

  • Won, S.H.;Lee, Y.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.250-255
    • /
    • 1991
  • Performance analysis of double-effect absorption heat pump system has been done to find improved working pairs (or mixture) by computer simulation. Based on the thermodynamic analysis, the coefficient of performance and mass flow ratio are investigated to compare three aqueous solutions [LiCl-water, LiSCN-LiBr-water, LiCl-$CaCl_2$-$Zn(NO_3)_2$-water] which was developed for only cooling, with conventional LiBr-water solution. It is found that the performances of the new aqueous solutions are better than that of LiBr-water solution not only in cooling systems, but also in heating systems. Theoretical thermodynamic performance data can be used in heat recovery systems by basic design data.

  • PDF

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building (오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교)

  • Jung Gun-Joo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments (공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo;Hwang, Sang-Kun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구)

  • Son, Won-Tug;Park, Kyung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.