• Title/Summary/Keyword: Double Heating

Search Result 237, Processing Time 0.024 seconds

Changes of Housing Styles in the Anbang of the Traditional Korean Farm House - After 1950 in Kyongki Province - (한국 전통 농가 안방의 주생활 변화과정 - 1950년대 이후 평택군 오성면의 농가를 중심으로 -)

  • 고도임
    • Journal of the Korean Home Economics Association
    • /
    • v.31 no.3
    • /
    • pp.197-212
    • /
    • 1993
  • The purpose of this study was to find out the physical change of the farm house and its anbang(the main room : master bed room), to identify the behavioral changes : activity and awareness of anbang, and to clarify the relationship between the physical changes of the farm house, and the behavioral changes of housing life-style in the anbang space. Bibliographical studies, cultural approaches and field survey method with questionnaire were used to collect data from 55 residents of Anwhari and Yangkyori in Pyong Teck Koon. Tables and drawings were made to analyze the data. The major findings were 1) the heating system of the ondol anbang. The most popular type is the double heating system(new pipes added to the traditional ondol). This combination ondol system brought some conviniences to the farmers. This change in structure of the ondol were of four types : Complete change in style, enlarged-completely changed style, partially changed style, enlarged-partially changed style. 2) from 1960 through 1970 lighting of the anbang changed room oil lamp to electricity. 3) the finishing material of the anbang floor changed from traditional oil paper and straw mats to vinyl flooring. 4) Traditional furniture and small decor items are gradually disappearing and are being replaced by modern items. 5) The awareness and actual use of the ondol anbang has not much changed from the multi-functional and sacred space of daily living : which are the characteristics of Korean traditional ondol anbang. The biggest consistency in the ondol anbang is the heating system of the floor, which is the characteristic of ondol culture in Korea. This system will continue regardless of time and place in Korea.

  • PDF

Installation and Operation of a Double-Sided Laser Heating System for the Synthesis of Novel Materials Under Extreme Conditions (극한 조건하에서 신물질 합성을 위한 양쪽 가열 레이저 가열 시스템 설치 및 운영)

  • Ko, Young-Ho;Oh, Kyoung Hun;Kim, Kwang Joo
    • New Physics: Sae Mulli
    • /
    • v.69 no.10
    • /
    • pp.1107-1114
    • /
    • 2019
  • Producing extremely stable high temperature and pressure condition is crucial in order to synthesize novel materials with various functions and to investigate their static and dynamic properties. Already a high pressure in the Mbar range, which is necessary to make novel materials, can be acquired by using a Diamond Anvil Cell (DAC), In this study, a laser-heating system combined with the DAC was designed and installed using two 1064-nm, 100-W fiber lasers on different sides of the DAC to heat the sample and three spectrometers to measure the temperature, pressure, and Raman spectra. A stainless-steel gasket, which is generally used as a sample chamber in high-pressure experiments, was heated to make a thermal radiation source, and the temperature of the heated gasket was obtained by measuring the spectrum of the radiation. By applying this technique, we were able to make various materials and to investigate their physical properties under extreme conditions.

A Study on characteristic of a double resonant type high frequency inverter using Phase-Shift (Phase-Shift를 이용한 복공진형 고주파 인버터의 특성에 관한 연구)

  • 조규판;김종해;남승식;김동희;노채균;배영호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.109-117
    • /
    • 2000
  • A full bridge type double resonant high frequency resonant inverter to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one and this paper also realize the output control of independence irrespective of the switching frequency using Phase-shift. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters, such as switching frequency, the variation of phase angle ($\phi$) of Phase-shift.

  • PDF

Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles (초미세입자 제거를 위한 나노세라믹 필터의 성능 평가)

  • Kim, Jong-Won;Ahn, Young-Chull;Yi, Byeong-Kwon;Jeong, Hyeon-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System (물-공기 지열 멀티형 열펌프 시스템 실증연구)

  • Kim, Cheol-Woo;Kim, Byoung-Kook;Lee, Pyeong-Gang;Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jong-Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

Energy Performance Evaluation of a Double-skin Facade with a Venetian Blind in Residential Buildings (주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구)

  • Lee, So-Yeun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • Apartment balcony has been remodeled since the government permitted remodeling in January 2006.But extended balcony has great impact on building heat gain and loss. Therefore It has problems such as increase of heating and cooling energy. So $\underline{t}echnical$ solutions about window solar gain in summer is an urgent matter. The Purpose of this study is to evaluate energy performance of a blind in a double-skin facade in residential buildings by using EnergyPlus program. The results show that slat angles of $90^{\circ}$ is best in energy performance if we do not consider daylight. Poorly daylighted living room needs electric light and it also causes high cooling load. On the other hand, the results show that the application of blinds controlled automatically is best for energy performance when we consider daylight. Blind slat angles of $50\sim60^{\circ}$ have best performance when blinds are controlled in this angle throughout the day on a clear day in August. Blind slat angles of $0\sim30^{\circ}$ have best performance when blinds $\underline{are\;controlled}$ in this angle throughout the day on a cloudy day (more than 7 of total sky cover) in August.

Seismic response characteristics according to the supporting conditions of middle slab of double-deck undersea tunnel using the centrifuge testing (원심모형 실험을 이용한 해저 복층터널 중간슬래브 지지조건에 따른 지진 응답특성)

  • Um, Ki-Yoon;Park, Inn-Joon;Kwak, Chang-Won;Jang, Dong-In
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.347-360
    • /
    • 2018
  • Due to the concentration and congestion of traffic in Seoul metropolitan area, effective utilization of underground space is required, and construction of various underground structures such as a double deck tunnel is increasing. Double deck tunnels are divided into upper and lower runways, and the most important part is middle slab. To investigate seismic behavior of middle slab, experimental study is required because of the complexity of the load and the mechanism of earthquake. In this study, centrifugal model tests were conducted to investigate the response characteristics of earthquake response according to the support conditions of the middle slab of a double deck tunnel. Artificial, Ofunato (short period) and Hachinohe (long period) seismic waves were employed in the experimental study. As a result, it was confirmed that the acceleration attenuation of elastomeric bearings condition was 10.6% in artificial earthquake, 13.6% in Ofunato earthquake, and 10.3% in Hachinohe earthquake. The results indicate that elastomeric bearings have some advantages in the viewpoint of seismic behaviors.

Effect of Cooking Methods with Various Heating Apparatus on the Quality Characteristics of Chicken (가열기구에 따른 조리방법이 닭고기의 품질특성에 미치는 영향)

  • Jeon, Ki-Hong;Kwon, Ki-Hyun;Kim, Eun-Mi;Kim, Young-Boong;Sohn, Dong-In;Choi, Jin-Young
    • Culinary science and hospitality research
    • /
    • v.20 no.3
    • /
    • pp.201-213
    • /
    • 2014
  • This study showed the quality characteristics of chicken breast meat(CB) and leg meat(CL) with various kinds of existing cooking methods and double layer pan filled with Phase Change Materials(PCM) heating. Steaming resulted the highest moisture contents of 63.9% and 62.1% each in CB and CL. Also, steaming showed the lowest with 1.3% and 8.6% of crude fat in CB and CL(p<0.05) respectively. Crude protein content of CB in charcoal heating and grilling of CL had the highest values of 37.9% and 30.5% each. In the test of crude ash, grilling showed the highest with 2.4% in CB(p<0.05) and oven heating and charcoal heating was the highest with 1.3% in CL(p<0.05). In the test of cooking loss, charcoal heating showed much higher with 33.52% and 41.16% in CB and CL each than the other cooking treatments. And in case of shear force test, $5.93kg/cm^2$ in CB and $6.80kg/cm^2$ in CL were the highest scores in grilling. In the test of color, L value of CB prepared by steaming showed the highest scores of 78.31(p<0.05) while CL by oven heating was the highest of 10.00 in a value. In the overall acceptability test of 9 point-scale sensory evaluation, CB prepared by charcoal heating showed the highest score of 7.25 points in boiling, but the lowest score of 6.00 points in steaming(p<0.05). CL by charcoal heating resulted the highest score of 7.71 points but had no significant difference.

A new formation method of silicon $p^+$-n-$n^+$junctions by VDH-implanter (VDH이온주입기에 의한 실리콘 $p^+$-n-$n^+$접합의 새로운 형성법에 관한 연구)

  • 최원은
    • 전기의세계
    • /
    • v.22 no.5
    • /
    • pp.5-11
    • /
    • 1973
  • A new method of forming silicon p$^{+}$-n-n$^{+}$ junctions has been attempted by using the VDH-Implanter (Vacuum Discharge and Heating). Each of p$^{+}$-n and n-n$^{+}$ junctions was formed on both sides of an n-type silicon substrate by means of predeposition of each dopant and their bombarding due to rarefied air ions together with the preheating of the substrate in the implanter. The recifying principle of the p$^{+}$-n-n$^{+}$ junctions is thought to be based on the theory of double injection. The I-V characteristic of the diode has shown that it has a fairly high forward current density with the desirable rise due to vary low voltage though the reverse voltage is a little low on account of the low resistivity of the silicon substrate.n substrate.

  • PDF

Performance Improvement of Power Control System for Driving MGT

  • Lee Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.744-749
    • /
    • 2005
  • This paper describes the performance improvement of power control system of magnetron (MGT) for microwave oven. The MGT is used extensively in household microwave oven and industrial microwave heating devices, and is operated by 3.0[kV] $\∼$5.0[kV] dc high voltage. The proposed power supply is consisted of a bridge rectifier, step-up converter(SUC) and its controller, half bridge inverter(HBI) and its controller, and full wave double voltage rectifier(DVR). In the proposed system, a good power factor can be obtained by the SUC' switching method that the inductor current waveforms follows that of the rectified voltage, and a line input power can be controlled to a range of 17.5[$\%$] by duty ratio (DR) adjustment of the HBI.