• Title/Summary/Keyword: Double Cone

Search Result 57, Processing Time 0.024 seconds

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.

Performance Comparison Study on LFLP and DBLP Daylighting System (LFLP와 DBLP 자연채광시스템의 성능평가 비교 연구)

  • Choi, Jeon-Yong;Kang, Eun-Chul;Lee, Euy-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.799-804
    • /
    • 2011
  • The LFLP (Linear Fresnel Light Pipe) system uses a linear Fresnel lens to follow the sun and concentrates the parallel sunlight into a line. A LFLP daylighting system has been developed and updated to a DBLP (Double Blind Light Pipe) daylighting system to improve the overall system efficiency in the morning and afternoon. The new design consists of a double-blind style with a cone-shaped light transformer. The blinds are used to collect the sun's altitude and azimuth movements through the day. Behind the two sets of blinds is the light transformer, which is based on a parabolic-shaped light concentrator. The light transformer is designed to efficiently deliver light within a thirty-degree radial spread so that the light pipe can internally reflect the light. The results of scale-model tests are encouraging, and the efficiency is three times higher than that of the previous LFLP system.

Single-flap versus double-flap approach for periodontal pocket reduction in supraosseous defects: a comparative study

  • Mathala, Venkata Lakshmi;Konathala, Santosh Venkata Ramesh;Gottumukkala, Naga Venkata Satya Sruthima;Pasupuleti, Mohan Kumar;Bypalli, Vivek;Korukonda, Radharani
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.239-253
    • /
    • 2021
  • Purpose: The single-flap approach (SFA) is a minimally invasive technique with limited mucoperiosteal flap elevation to gain access to the buccal/palatal aspects, thus limiting post-surgical complications. The purpose of the present study was to gain insights into the impact of the SFA over the double-flap approach (DFA) on periodontal flap treatment outcomes and patient compliance in terms of discomfort and time taken for surgical procedures. Methods: Twenty patients with persistent probing pocket depths of ≥5 mm were scheduled for the SFA (test site) and for the DFA (control site). All the clinical periodontal parameters were recorded at baseline, 3 months, and 6 months. Radiographic bone level (cone-beam computed tomography) was evaluated at baseline and 6 months. Patients' postoperative pain perception and wound healing were also assessed. Results: The SFA showed a significant reduction in periodontal pocket depth, gain in clinical attachment level (CAL), and gain in bone level when compared with the DFA. The SFA substantially improved wound healing and induced less postoperative pain than the DFA. Conclusions: The SFA resulted in substantial improvement in the composite outcome measures, as shown by a reduction in pocket depth with minimal gingival recession, gain in CAL, early wound healing, less postoperative discomfort, and better patient-centered outcomes.

Comparison of retention forces with various fabrication methods and materials in double crowns

  • Guven, Melahat Celik;Tuna, Meral;Bozdag, Ergun;Ozturk, Gizem Nur;Bayraktar, Gulsen
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.308-314
    • /
    • 2017
  • PURPOSE. The purpose of this study was to analyze the retention force changes and wear behaviours of double-crown systems over long-term use. MATERIALS AND METHODS. Ten groups, each consisting of six samples, were evaluated. Specifically, casting gold alloy primary crown - casting gold alloy secondary crown (AA), laser sintering primary crown - laser sintering secondary crown (LL), casting Cr alloy primary crown - casting Cr alloy secondary crown, (CC) zirconia primary crown - electroformed secondary crown (ZA), and CAD/CAM titanium alloy primary crown - CAD/CAM titanium alloy secondary crown (TT) groups were evaluated at cone angles of $4^{\circ}$ and $6^{\circ}$. The samples were subjected to 5,000 insertion-separation cycles in artificial saliva, and the retention forces were measured every 500 cycles. The wear levels were analyzed via SEM at the beginning and end of the 5,000 cycles. RESULTS. In all samples, the retention forces increased when the conus angle decreased. The highest initial and final retention force values were found in the $LL-4^{\circ}$ group (32.89 N-32.65 N), and the lowest retention force values were found in the $ZA6^{\circ}$ group (5.41 N-6.27 N). The ZA groups' samples showed the least change in the retention force, and no wear was observed. In the other groups, wear was observed mostly in the primary crowns. CONCLUSION. More predictable, clinically relevant, and less excursive retention forces can be observed in the ZA groups. The retention force values of the LL groups were statically similar to those of the other groups, except the ZA groups.

Study on the Development of High-speed Rotary Tilling System for Power Tiller (경운기의 고속 로터리 경운시스템 개발에 관한 연구)

  • 이승규;김성태;우종구;김재영
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.423-430
    • /
    • 2001
  • The purpose of this study is to develop high-speed rotary tillage system for a power tiller by improving the rotary blade and the power train of transmission. Mechanical structure of gear train of rotary drive of conventional power tiller was simplified so that power can be transmitted directly from second shaft to tilling speed change shaft by rotating freely the transfer gear which changes the direction of rotation of shafts using needle bearing installed into middle shaft. A new gear train suitable for the single-edged rotary blade and high-speed rotary drive was developed with the rotational speed of rotary shaft faster than 7.5% at 1st-speed and 1.4% at 2nd-speed the one of conventional system by changing the numbers of teeth of gears of middle shaft, tilling speed change shaft and PTO shaft. Using the developed gear train for high-speed rotary drive, field tests were performed to compare tillage performances by the developed single-edged blade and by the conventional double-edged blade. The results showed that the performances by the single-edged blade compared with the one by the double-edged blade was improved about 18% in field capacity, about 34% in fuel consumption, and 9.4% in soil crushing ratio. Therefore, it may be concluded that tillage performance by the single-edged blade was improved compared to the one by the conventional blade. Evaluation of the developed system consisting of single-edged blade and gear train for high-speed rotary drive in field revealed that tillage performance of the developed system was similar to the one of field test conducted using the system consisting of single-edged blade and gear train for rotary drive of conventional power tiller However, considering the higher cone index of the upland field where evaluation was carried out compare to the one of the ordinary paddy field, it may be concluded that tillage performance of the developed rotary tilling system better than the one of conventional system.

  • PDF

Design of a Light Collector with Two-story LED Mounting Holder for a Fiber-optic Illuminator (광파이버 일루미네이터의 2층구조형 LED 집광판 설계)

  • Kim, Wan-Ho;Park, Jun-Seok;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.255-258
    • /
    • 2001
  • This paper proposes a new structure of a fiber-optic illuminator using high Lux RGB LEDs. A simulation program, LightTools, is used for the verification of the model. An LED mounting holder containing 74 RGB LEDs is used as a basic part of its light collector. Since the light output level of current LED lamps is still far below that of conventional lamps, it is required to double the right output in order to replace a conventional illuminator with a halogen lamp. An additional cone-type reflector is installed hemispherically and the resulting structure comprises a basic collector unit. To further increase the output two collector units are connected together in series. As the result, the light output increases nearly 70% with compared to a collector with a basic structure. The system efficiency can be increased more than 8 times with compared to conventional one.

  • PDF

CFD in Hypersonic Flight

  • Park, Chul
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.1-8
    • /
    • 2009
  • This is a short review of how CFD contributed to hypersonic flights in the past 50 years. Two unexpected phenomena that occurred in the entry flights of the Apollo and Space Shuttle made us aware of the impact of the high temperature real-gas effects on hypersonic flights: pitching moment anomaly of up to 4 degrees, and radiation overshoot behind a shock wave. The so-called two-temperature nonequilibrium model was introduced to explain these phenomena. CFD techniques were developed to accommodate the two-temperature model. Presently, CFD can predict trim angle of attack to an accuracy of about 1 degree. A concerted effort was made to numerically reproduce the experimentally measured flow-field over a double-cone. As yet, perfect agreement between the experimental data and computation is not achieved. Scramjet technology development is disappointingly slow. The phenomenon of ablation during planetary entries is not yet predicted satisfactorily. In the future, one expects to see more research carried out on planetary entries and space tourism.

  • PDF

Influencing Factors on Toughness of Ring Type Fiber Concrete (원형강섬유 콘크리트의 인성 영향요인)

  • Choi, Oan-Chul;Lee, Cha-Don;Hur, Jun;Kim, Su-Hyen
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.55-60
    • /
    • 2001
  • Influencing factors on flexural toughness of ring-type fiber reinforced concrete(RSFRC) are investigated. An experiment proceeding ASTM C 78 is peformed to make a comparison between ring-type fibers and double-hook type fibers. Most specimen with ring type fibers have failed by the cone type failure, while discrete hook type fibers have failed by fiber pullout. For the hook-type fiber reinforced concrete(SFRC), the first crack load increases, as the fiber mixing volume increases. Aspect ratio(fiber length/fiber diameter) is critical for hook type fibers, so the flexural toughness increases significantly, as the length of fiber increases. However, for the ring type, the toughness indices Increase as the number of fibers in the specimen increases. Since there is no bond problem between the ring fiber and the concrete matrix, the aspect ratio does not affect the performance of the composite material with the newly developed steel fibers. Influencing factors with respect to flexural toughness RSFRC were observed to be ring diameter, diameter of steel fiber and fiber content.

  • PDF

Design of Butterfly Valve Disk to Minimize Interference at Opening and Closing (개폐 시 최소 간섭을 갖는 버터플라이 밸브 디스크의 설계)

  • Choi Young;Boo Kwangsuk;Yeo Hong-Tae;Hur Kwando;Kim Hokwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.140-145
    • /
    • 2004
  • In this study, the design and analysis of a butterfly valve disk was performed to minimize the rubbing between the disk and the seat at opening and closing. The butterfly valve has double eccentric structure and the contact surface between the disk and the seat is a conical surface. At the instant of opening and closing the valve by the rotation of disk, the positions of zero contact point are changed. Also, if the cone surface is cut in the perpendicular direction to the rotation axis of the valve, the contour of cutting section is hyperbolic. Therefore minimum distance between the origin of the eccentric axis and the hyperbolic curve goes to the position of zero contact point. In order to consider the interferences between the disk and the seat, the thermal-structure coupled field analysis was performed by ANSYS.

LES OF TURBULENT PREMIXED COMBUSTION FLAME AND LES APPLICATION FOR THE INDUSTRIAL COMBUSTOR DEVELOPMENT (난류 예혼합연소 화염의 LES 및 산업용 연소기 개발을 위한 LES 응용 해석 기술)

  • Park, Nam-Seob;Ryu, Jong-Hyuk
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.437-441
    • /
    • 2010
  • LES results of turbulent premixed combustion flows are introduced by using the dynamic sub-grid scale model based on G-equation describing the flame front propagation. The turbulent premixed combustion flows around bluff body and over backward facing step are analyzed to validate present formation. LES of swirling partially premixed combustion flame is also performed to conform the predictive capabilities of LES model and to prompt our understanding for the combustion flows over double cone swirl burner combustor by using CFD-ACE+ commercial code.

  • PDF