• 제목/요약/키워드: Double Ball-bar

검색결과 23건 처리시간 0.03초

복합공작기계의 이송계 운동정밀도 측정의 연구 (A Study on the Measurement of Motion Accuracy for Feed Drive System of Multi-task Machine Tool)

  • 고해주;정윤교
    • 한국기계가공학회지
    • /
    • 제6권3호
    • /
    • pp.112-118
    • /
    • 2007
  • Recently, the machine tools called multi-task machines, which mounted rotary axes on the table or spindle are used increasingly. Accordingly, multi-task machine tool takes a growing interest on the motion accuracy of feed drive system. In this study, measurement and diagnosis of motion errors ware attempted from circular pattern obtained by using DBB (Double ball bar) device. Those were obtained at both clockwise and counter clockwise motions in mutually perpendicularly intersecting three planes. The reliability of error measurement system for multi-task machine tool was verified by the direct test cutting.

  • PDF

복합공작기계의 이송계 운동정밀도 측정의 연구 (A Study on the Measurement of Motion Accuracy for Feed Drive System of Multi-task Machine Tool)

  • 고해주;정윤교
    • 한국기계가공학회지
    • /
    • 제6권3호
    • /
    • pp.31-37
    • /
    • 2007
  • Recently, the machine tools called multi-task machines, which mounted rotary axes on the table or spindle are used increasingly. Accordingly, multi-task machine tool takes a growing interest on the motion accuracy of feed drive system. In this study, measurement and diagnosis of motion errors ware attempted from circular pattern obtained by using DBB (Double ball bar) device. Those were obtained at both clockwise and counter clockwise motions in mutually perpendicularly intersecting three planes. The reliability of error measurement system for multi-task machine tool was verified by the direct test cutting.

  • PDF

머시닝센터의 다축오차 평가 방법 (Evaluation Method of the Multi-axis Errors for Machining Centers)

  • 황주호;심종엽;고태조
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.904-914
    • /
    • 2011
  • The volumetric errors of CNC machining centers are determined by 21 errors, including 3 linear errors, 6 straightness errors, 3 perpendicular errors, 9 angular errors and non-rigid body errors of the machine tool. It is very time consuming and hard to measure all of these errors in which laser interferometer and other parts are used directly. Hence, as many as 21 separate setups and measurements are needed for the linear, straightness, angular and perpendicular errors. In case of the 5-axis machining centers, two more rotary tables are used. It can make 35 error sources of the movement. Therefore, the measured errors of multi movements of the 5-axis tables are very complicated, even if the relative measured errors are measured. This paper describes the methods, those analyze the error sources of the machining centers. Those are based on shifted diagonal measurements method (SDM), R-test and Double ball bar. In case, the angular errors of machine are small enough comparing with others, twelve errors including three linear position errors, six straightness errors and three perpendicular errors can be calculated by using SDM. To confirm the proposed method, SDM was applied to measuring 3 axes of machine tools and compared with directly measurement of each errors. In addition, the methods for measuring relative errors of multi-axis analysis methods using R-test and Double Ball Bar are introduced in this paper.

5축 혼합형 공작기계의 정밀도 향상 연구 (Accuracy Improvement of a 5-axis Hybrid Machine Tool)

  • 김한성
    • 한국산업융합학회 논문집
    • /
    • 제17권3호
    • /
    • pp.84-92
    • /
    • 2014
  • In this paper, a novel 5-axis hybrid-kinematic machine tool is introduced and the research results on accuracy improvement of the prototype machine tool are presented. The 5-axis hybrid machine tool is made up of a 3-DOF parallel manipulator and a 2-DOF serial one connected in series. The machine tool maintains high ratio of stiffness to mass due to the parallel structure and high orientation capability due to the serial-type wrist. In order to acquire high accuracy, the methodology of measuring the output shafts by additional sensors instead of using encoder outputs at the motor shafts is proposed. In the kinematic view point, the hybrid manipulator reduces to a serial one, if the passive joints in the U-P serial chain at the center of the parallel manipulator are directly measured by additional sensors. Using the method of successive screw displacements, the kinematic error model is derived. Since a ball-bar is less expensive than a full position measurement device and sufficiently accurate for calibration, the kinematic calibration method of using a ball-bar is presented. The effectiveness of the calibration method has been verified through the simulations. Finally, the calibration experiment shows that the position accuracy of the prototype machine tool has been improved from 153 to $86{\mu}m$.

레이저 트래커를 이용한 소형 공작기계의 서보 불일치 추정 (Servo Mismatch Estimation of Miniaturized Machine Tools Using Laser Tracker)

  • 이훈희;권성환;손진관;양승한
    • 한국정밀공학회지
    • /
    • 제33권8호
    • /
    • pp.683-689
    • /
    • 2016
  • Servo mismatch, which affects positioning accuracy of multi-axis machine tools, is usually estimated via the circular test. However, due to mechanical restrictions in measuring instruments, the circular test using a double ball-bar is difficult to apply in miniaturized or super-large sized machine tools. Laser trackers are widely used to measure the form accuracy of parts and the positioning accuracy of driving systems. In this paper, a technique for the servo mismatch estimation of multi-axis machine tools is proposed via the circular test using a laser tracker. To verify the proposed technique, experiments using a double ball-bar and laser tracker are conducted in a 3-axis machine tool. The difference in the evaluation results is 0.05 msec. The servo mismatch for the miniaturized machine tool is also evaluated using the proposed technique.

수치제어 공작기계의 위치오차 측정 및 보정시스템 개발 (Development of an NC Machine Performance Test and Calibration System)

  • 이상윤;박준호;조선휘;김문상
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1431-1440
    • /
    • 1993
  • This paper presents a new NC machine performance test and calibration system. In order to measure NC machine erros in simpler, and less time-comsuming way, some indirect measuring systems such as circular disk system and double ball bar system have been developed instead of laser interferometer. But these indirect measuring systems have shown their limits in identifying each of NC machine error sources in absolute numerical value. Therefore, we developed an unique NC machine error measurement system which provides a simple measuring process like other conventional indirect methods and still can indentify each of NC machine error sources in absolute numerical value.