• 제목/요약/키워드: Dot

검색결과 1,583건 처리시간 0.032초

Dot 패턴 된 감광성 CNT 페이스트의 전계방출 특성 향상 (Improvement of Field Emission Characteristics of Dot-patterned Photo Sensitive CNT Paste)

  • 김진희;이한성;전지현;곽정춘;이내성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.155-156
    • /
    • 2007
  • Fabrication of dot-patterned carbon nanotube (CNT) emitters with excellent field emission properties using photo-sensitive CNT paste is described. The photosensitive CNT paste showed good photo-patternability, which led us to easily form $10-{\mu}m$-diameter dot arrays. We presented a parametric study on formulating the photo-sensitive paste and their resultant field emission characteristics.

  • PDF

윤곽진동모드 압전트랜스포머의 3차원 시뮬레이션에 관한 연구 (A Study on the 3-D Simulation of Contour Vibration Mode Piezoelectric Transformer)

  • 홍재일;류주현;정영호;박창엽;김종선;유충식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.423-426
    • /
    • 2000
  • The 3-D $31.5$\times$31.5$\times$2.5mm$^3$model of contour vibration mode piezoelectric transformer with Pb($Ni_{1/2}$$W_{1/2}$)$O_3$-Pb(Zr,Ti)$O_3$ ceramics was simulated by ANSYS according to the dot size 17, 18, 19, 20, 21 $mm\phi$ and analyzed the results. The mechanical quality factor of the 3-D model was decreased with the dot size and increased as 2605 at 20 $mm\phi$ and after then decreased again. The output voltage of that sample was 74123 [V] and the maximum stress of the dot electrode at that sample was 288[$10^7$N/$m^2$] and the maximum displacement of the ring electrode at that sample was 128 [$\mu\textrm{m}$].

  • PDF

TOF-MEIS System을 이용한 Ultra Thin Film 및 Composition and the Core/Shell Structure of Quantum Dot 분석

  • 정강원;김재영;문대원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.284-284
    • /
    • 2013
  • 중 에너지 이온 산란 분석법(Medium Energy Ion Scattering Spectrometer, MEIS)은 50~500 keV로 이온을 가속 후 시료에 입사시켜 시료의 원자와 핵간 충돌로 산란되는 일차이온의 에너지를 측정하여 시료를 분석하는 기법으로, 원자층의 깊이 분해능으로 초박막의 표면 계면의 조성과 구조를 분석 할수 있는 유용한 미세 분석기술이다. 본 실험에서 에너지 70~100 keV의 He+ 이온을 사용하여 Pulse Width 1 ns의 Pulsed ion beam을 만들어 Start 신호로 사용하고 Delay-line-detector에 검출된 신호를 End 신호를 이용한 TOF-MEIS System을 개발하였다. 활용 가능한 분석시편으로 Ultra thin film 시편으로 1, 1.5, 2, 2.5, 3, 4 nm의 HfO2, 1.8, 4nm의 SiO2 시편을 분석 하였으며 Ultra Shallow Junction 시편으로 As Doped Si, Cs Doped Si 시편 및 Composition, Core/shell 구조의 Q-dot 시편으로 CdSe, CdSe/ZnS등 다양한 분석 실험을 진행 하였다. Composition, Core/shell 구조의 Q-dot 시편은 Diamond Like Carbon(DLC)의 Substrate에 Mono-layer로 형성하여 분석하였다.

  • PDF

NBLAST: a graphical user interface-based two-way BLAST software with a dot plot viewer

  • Choi, Beom-Soon;Choi, Seon Kang;Kim, Nam-Soo;Choi, Ik-Young
    • Genomics & Informatics
    • /
    • 제20권3호
    • /
    • pp.36.1-36.6
    • /
    • 2022
  • BLAST, a basic bioinformatics tool for searching local sequence similarity, has been one of the most widely used bioinformatics programs since its introduction in 1990. Users generally use the web-based NCBI-BLAST program for BLAST analysis. However, users with large sequence data are often faced with a problem of upload size limitation while using the web-based BLAST program. This proves inconvenient as scientists often want to run BLAST on their own data, such as transcriptome or whole genome sequences. To overcome this issue, we developed NBLAST, a graphical user interface-based BLAST program that employs a two-way system, allowing the use of input sequences either as "query" or "target" in the BLAST analysis. NBLAST is also equipped with a dot plot viewer, thus allowing researchers to create custom database for BLAST and run a dot plot similarity analysis within a single program. It is available to access to the NBLAST with http://nbitglobal.com/nblast.

슬관절 운동 평가를 위한 생체 임피던스 측정용 전도성 섬유센서 개발 및 평가 (Development and Assessment of Conductive Fabric Sensor for Evaluating Knee Movement using Bio-impedance Measurement Method)

  • 이병우;이충근;조하경;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권1호
    • /
    • pp.37-44
    • /
    • 2011
  • This paper describes the development and assessment of conductive fabric sensor for evaluating knee movement using bio-impedance measurement method. The proposed strip-typed conductive fabric sensor is compared with a dot-typed Ag/AgCl electrode for evaluating validity under knee movement condition. Subjects are composed of ten males($26.6{\pm}2.591$) who have not had problems on their knee. The strip-typed conductive fabric sensor is analyzed by correlation and reliability between a dot-typed Ag/AgCl electrode and the strip-typed conductive fabric sensor. The difference of bio-impedance between a dot-typed Ag/AgCl electrode and the strip-typed conductive fabric sensor averages $7.067{\pm}13.987\;{\Omega}$ As the p-value is under 0.0001 in 99% of t-distribution, the strip-typed conductive fabric sensor is correlated with a dot-typed Ag/AgCl electrode by SPSS software. The strip-typed conductive fabric sensor has reliability when it is compared with a dot-typed Ag/AgCl electrode because most of bio-impedance values are in ${\pm}1.96$ standard deviation by Bland-Altman Analysis. As a result, the strip-typed conductive fabric sensor can be used for assessing knee movement through bio-impedance measurement method as a dot-typed Ag/AgCl electrode. Futhermore, the strip-typed conductive fabric sensor is available for wearable circumstances, applications and industries in the near future.

Doublet 반사경을 이용한 도트 사이트 장치의 개발 (Development of the Dot Sight Device by Using the Doublet Reflector)

  • 이동희
    • 한국안광학회지
    • /
    • 제13권1호
    • /
    • pp.65-69
    • /
    • 2008
  • 목적: Doublet 반사경을 이용한 조준사격용 도트 사이트 장치의 개발. 방법: Sigma 2000 광학 설계 프로그램으로 Singlet 반사경과 Doublet 반사경을 설계하여 비교 검토하였다. 결과: 유한광선수차 분석에서 기존 Singlet 반사경을 사용한 도트 사이트 장치에 비해 시차(parallax)가 제거된 유효 시야가 3.3배 확대되는 성능을 보인다. Doublet 반사경을 사용하는 경우 광학계의 중심 두께가 기존 Singlet 반사경을 사용한 경우보다 2배 이상 두꺼워지기 때문에 목표점이 관측자의 망막에 결상할 때 Singlet 반사경의 경우와 같이 제1면과 제3면의 곡률반경을 동일하게 할 경우에는 배율 변화가 나타난다. 이를 극복하기 위해 Doublet 반사경인 경우에는 어포칼 조건을 만족하는 것이 필요하다. 결론: 기존의 Singlet 반사경의 방식보다 시차(parallax)가 제거된 유효 시야가 3.3배 확대되는 성능을 가지는 Doublet 반사경을 이용한 조준사격용 도트 사이트 장치를 개발하였다.

  • PDF

수소연료탱크용 복합소재 압력용기에 관한 강도안전성 평가연구 (Strength Safety Evaluation of Composite Pressure Container for Hydrogen Fuel Tanks)

  • 김청균;김도현
    • 한국가스학회지
    • /
    • 제15권1호
    • /
    • pp.30-34
    • /
    • 2011
  • 본 논문은 104L의 저장용량과 70MPa의 사용압력을 갖는 수소연료탱크용 복합소재 압력용기에 관한 강도안전성을 해석한 평가연구이다. 탄소섬유 복합용기의 내측은 6061-T6의 알루미늄 라이너를 사용하고, 외경측은 원주방향을 따라서 탄소섬유 후프층을 형성하고, 또한 $12^{\circ}C$ 적층과 $70^{\circ}C$ 적층을 헤리컬방향으로 경사지게 감아서 제작하였다. 복합소재 연료탱크의 강도안전성에 대한 FEM 해석결과는 US DOT-CFFC와 KS B ISO 11119-2 규정에 따라 평가되었다. FEM 해석결과에 의하면, 104L의 복합용기로 제시된 설계모델을 US DOT-CFFC와 KS B ISO 11119-2 기준으로 평가할 때 모두 안전하다할 수 있다. 그렇지만, 탄소섬유 연료탱크에 대한 계산결과는 한국의 평가기준을 사용하기보다는 미국의 안전기준을 적용하는 것이 더 안전하다는 해석결과를 알 수 있다. 따라서 70MPa의 수소연료 압력용기의 강도안전성을 충분히 확보하기 위해서는 미국의 DOT-CFFC 안전기준에 의거 평가하고 설계하는 것이 바람직하다.