• 제목/요약/키워드: Dosimetry program

검색결과 67건 처리시간 0.033초

Derivation of site-specific derived concentration guideline levels at Korea Research Reactor-1&2 sites

  • Kim, Geun-Ho;Do, Tae Gwan;Kwon, Jae;Ryu, Gangwoo;Kim, Kwang Pyo
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.493-500
    • /
    • 2022
  • The objective of this study was to derive derived concentration guideline levels (DCGLs) reflecting the site-specific characteristics of KRR-1&2. A total of 7 nuclides (H-3, C-14, Co-60, Sr-90, Cs-137, Eu-152, and Eu-154) were selected for DCGLs derivation. Radiation dose at the sites was evaluated with RESRAD-ONSITE program. The dose contribution due to direct external exposure was the highest during the entire evaluation period. Ingestion had the second effect. The DCGLs of Co-60 was derived to be 0.051 Bq/g, and DCGLs of Cs-137 was 0.193 Bq/g. The DCGLs of H-3 showed the highest value of 129 Bq/g. The ratio of DCGLs derived by applying site-specific values and default values ranged from 0.27 to 19.6. For six nuclides excluding H-3, KRR-1&2 sites and the overseas NPP sites showed similar DCGLs. H-3 showed large differences in DCGLs from this study and overseas NPPs. The large difference resulted from input parameter values applied to the sites. In conclusion, it is critical to apply site-specific parameter values reflecting the site characteristics to derive DCGLs for decommissioned site clearance. The result of this study can be used as a reference for nuclide selection and DCGLs derivation reflecting the site characteristics when decommissioning nuclear facilities, including nuclear power plants in Korea.

Comparison of plan dosimetry on multi-targeted lung radiotherapy: A phantom-based computational study using IMRT and VMAT

  • Khan, Muhammad Isa;Rehman, Jalil ur;Afzal, Muhammad;Chow, James C.L.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3816-3823
    • /
    • 2022
  • This work analyzed the dosimetric difference between the intensity modulated radiotherapy (IMRT), partial/single/double-arc volumetric modulated arc therapy (PA/SA/DA-VMAT) techniques in treatment planning for treating more than one target of lung cancer at different isocenters. IMRT and VMAT plans at different isocenters were created systematically using a Harold heterogeneous lung phantom. The conformity index (CI), homogeneity index (HI), gradient index (GI), dose-volume histogram and mean and maximum dose of the PTV were calculated and analyzed. Furthermore, the dose-volume histogram and mean and maximum doses of the OARs such as right lung, contralateral lung and non GTV were determined from the plans. The IMRT plans showed the superior target dose coverage, higher mean and maximum values than other VMAT techniques. PA-VMAT technique shows more lung sparing and DA-VMAT increases the V5/10/20 values of contralateral lung than other VMAT and IMRT techniques. The IMRT technique achieves highly conformal dose distribution to the target than other VMAT techniques. Comparing to the IMRT plans, the higher V5/10/20 and mean lung dose were observed in the contralateral lung in the DA-VMAT.

Buchler 강내조사장치의 선량계산에 대한 연구 (Dose Calculation for the Buckler Remote Afterloading System)

  • 정원규;김수곤;강정구;이정옥;문성록;김승곤
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.247-253
    • /
    • 1996
  • 목적 : Buchler type의 강내조사장치에 대한 선량계산 프로그램을 개발하였다. 방법 : 프로그램 디스크를 5도씩 72 분할하여 구한 좌표에서 선원의 왕복 크기와 activity의 분포를 결정하였다. 각각의 프로그램 디스크별 그리고 각 선원별로 선량율을 계산하여 선량율 표를 작성하였다. 이 선량율표를 이용하여 인체내 관심점에 대한 선량율 계산에 이용하도록 하였다. 각 관심점에 대한 선량율을 계산한 후 등선량 분포곡선을 작성하여 화면에 표시하였다. 결과 : 각 프로그램 디스크와 선원별로 선량율표를 작성하므로써 저장 용량은 다소 증가한다. 그러나 인체내 관심점의 선량 계산이 빠르게 이루어지기 때문에 환자 치료시 바로 이용할 수 있다. 또한 등선량곡선을 바로 확인할 수 있어 선원의 배열 등을 즉시 교정 할 수 있다. 결론 : 종전의 등선량 분포곡선을 이용한 근사적 계산보다 정확한 선량 계산을 훨씬 빠르게 할 수 있다. 선량계산 문제점의 해결로 Buchler type의 강내조사장치를 다양하게 치료에 응용할 수 있다. 또한 다양한 선원에 대한 선량계산에도 이용할 수 있다.

  • PDF

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.

한국 노인의 일반촬영 이용량 및 피폭선량: 2016년 고령환자데이터 기반 (General Radiography Usage and Exposure Dose of Korean Elderly: Based on Data from Aged Patients in 2016)

  • 길종원;유세종;이원정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.495-502
    • /
    • 2021
  • This study aims to provide basic data for elderly health insurance policy and medical radiation safety management by analyzing the general radiography usage and exposure dose of the elderly in Korea. The effective dose for each general radiography was calculated using the ALARA-GR program for 260 general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2016 elderly patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was applied. The general radiography usage and exposure dose per person aged 65 years and over was 6.47 cases and 0.56 mSv. Females showed higher value than males as 7.15 cases and 0.66 mSv(p<.001). By age, those between 75 and 79 showed the highest number as 6.97 cases and 0.62 mSv(p<.001). Those who were supported by Medical Aid showed higher value than those who were insured by National Health Insurance as 8.82 cases and 0.76 mSv(p<.001). In addition, the ratio by radiography was in the order of Chest 20.85%, Knee Joint 15.58%, and L-spine 14.67%, and the exposure dose was L-spine 29.40%, Chest 15.82%, Abdomen 7.97%, and Entire Spine 7.20%. General radiography, which is widely used due to the high frequency of diseases in the elderly population should be taken into consideration when establishing health insurance policies. In addition, it is necessary to check whether the general radiography with high exposure dose is performed as a routine examination without considering medical necessity.

입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터 (General Radiography Imaging Usage and Effective Dose of Inpatients: Based on Data from Inpatients in 2018)

  • 길종원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.107-116
    • /
    • 2024
  • In this study, we analyzed the use of general radiography imaging and effective dose in inpatients. Our aim is to help reduce national medical radiation exposure doses and develop rational health-care financial policies. The effective dose for each general radiography was calculated using the ALARA-GR program for 53 types (total: 260 codes) general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2018 inpatient patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was analyzed. 89.00% of inpatients undergo general radiography imaging at least once, with an average of 12.63 scans per person and an effective dose of 1.00 mSv. Those who received support from Medical Aid showed a higher value compared to those who were insured by National Health Insurance, with 17.39 cases and 1.43 mSv (p<.001). Chest had the highest usage rate at 23.12% for general radiography imaging, while L-spine had the highest effective dose at 24.53%. It is estimated that 420 inpatients patients undergo 121 to 820 general radiography imaging procedures per year, and 233 inpatients are estimated to have an annual effective dose of >20.00~58.25 mSv. Rational use of health-care finances and the practice of medical radiation safety management are essential for the well-being of individuals, the enhancement of quality of life, and the improvement of health-care quality.

선량 판독용 OSL 측정장치의 개발 (Development of OSL Dosimetry Reader)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.10-15
    • /
    • 2012
  • 개인 선량계로 활용될 수 있는 광자극발광(OSL: optically stimulated luminescence) 측정장치의 개발과 이를 위한 이론적 배경 및 개발된 장치의 성능에 대하여 기술하였다. OSL 측정장치는 자극광원과 시료로부터 자극 발광된 광신호 사이의 간섭효과를 최소화하기 위하여 다양한 광학적 필터 조합을 구성해야 하는데, 여기서는 자극광에는 GG420 필터를, 측정부에는 UG11과 BG39 필터로 $Al_2O_3:C$ OSL 물질에 최적화된 광학적 필터를 구성하였다. 자극광원으로 Luxeon V형 고휘도 Blue LED를 선택함으로서 충분한 광량을 확보하였다. 또한 장비 제어 및 측정을 위하여 PC와 OSL 장치 사이에 다양한 제어보드들이 이용되며, 전체 장치의 자동화 및 장치제어는 LabView 프로그램을 이용하여 개발하였다. 개발된 OSL 장치의 신뢰도 및 재현성 평가를 위해 대표적인 OSL 물질인 $Al_2O_3:C$를 이용하여 OSL 특성곡선을 측정하고 이를 기존 상용 OSL 측정장치와 비교하였다.

고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사 (External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities)

  • 최창헌;김정인;박종민;박양균;조건우;조운갑;임천일;예성준
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.50-56
    • /
    • 2010
  • 목 적: 제 3기관에 의해 독립적으로 수행된 방사선 치료 빔의 흡수 선량을 외부 감사의 결과로 보고 한다. 이를 위해 쉽고 편리하게 설치 가능 한 고체 팬텀을 이용하여 흡수 선량을 측정하는 방법을 개발했다. 대상 및 방법: 2008년 12개 방사선 치료 시설에서 외부 감사 프로그램에 참여하였고 47개의 광자선과 전자선의 제 3기관에 의해 American Association of Physicists in Medicine (AAPM) task group (TG)-51 프로토콜을 사용하여 독립적으로 교정되었다. AAPM TG-51 프로토콜은 물에서의 측정을 권고 하고 있지만 팬텀으로 물은 바쁜 병원 상황에선 몇 가지 단점이 있다. 설치와 수송이 편리하고 재현성이 있는 고체 팬텀을 사용하였다. 광자선과 전자선에 대한 물과 고체 팬텀 사이의 선량 보정인자는 스케일링 방법과 실험적 측정에 의해 결정되었다. 결 과: 대부분의 빔은(74%) 제3기관의 프로토콜로 측정한 결과 2%의 편차 이내였다. 그러나 20개 중 2개의 광자선과 27개 중 3개의 전자선은 허용범위(3%)를 초과 하였다. 특히 그중 2개의 빔은 10% 이상의 편차를 보여주고 있다. 6 MV 초과의 고에너지 광자선은 보정인자가 없었다. 6 MV 광자선의 경우 고체 팬텀에서의 흡수선량은 물에서의 흡수 선량보다 0.4% 작게 나타났다. 전자선에 대한 보정인자도 결정되었는데 전자선의 에너지가 증가함에 따라 보정인자는 작아지는 경향을 보여준다. 고체팬텀을 사용한 TG-51 프로토콜의 측정 오차는 ${\pm}1.22%$로 나타났다. 결 론: 개발된 방법은 다기관 임상 연구의 인증 프로그램에 참여할 수 있는 외부 감사 기관 프로그램에 성공적으로 적용되었다. 이 선량측정은 선량을 측정하기 위한 시간을 줄이고 물을 설치할 때의 생길 수 있는 측정오차를 감소시킨다.

방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가 (Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.123-130
    • /
    • 2000
  • 전리계의 성능은 방사선 선량측정의 정확도와 정밀도에 직접적으로 영향을 준다. 본 연구에서는 전리계의 성능을 유지하기 위한 정도관리의 항목들을 제시하고 구체적인 성능검사를 시행하고자 한다. 선정된 성능평가 항목들은 적절한 인가전압, 예열 및 고전압 후의 평형시간, 누설에 의한 상쇄 전류, 방사선 측정 전후의 영점이동 (배경전류), 장시간 안정성, 선형성, 외부조건의 영향 등이었다. 전리계에 연결된 자루가 단단한 전리함과 방사선원으로 스트론티움-90이 내장된 검사기가 성능검사용으로 이용되었다. 인가전압의 측정은 전리함의 입력단자에서 직접 측정하였고 평형시간의 측정은 전리계에 전원을 연결한 후와 인가전압을 바꾼 후 검사기에 연결된 전리함의 반응이 안정을 가져오는 시간으로 측정하였다. 누설은 전리계가 안정된 후 방사선을 조사하지 않은 상태에서 전리계의 측정값이 영점에서 이동하는 것으로 나타냈으며 배경전류는 안정된 전리계의 영점을 조정하고 전리계에 연결된 검사기에서 전리함을 10분 조사한 후 영점의 변화로 나타냈다. 장시간의 안정성 3개월에 걸쳐 측정되었으며 이때 검사기의 측정값을 온도-기압에 대한 보정을 한 후 그 값을 비교하였다. 선형성은 전리계에 연결된 전리함을 n번 연속하여 조사하여 그 전체의 측정값과 초기값을 n번 곱한 값을 비교하였다. 외부조건의 영향은 인위적으로 외부온도를 17-34 $^{\circ}C$ 로 변화시켜서 환경변화에 의한 전리계의 영점이동으로 나타냈다. 인가전압의 측정에서 명목상의 인가전압 300, 500V에 대한 측정값은 각각 2.5%와 5.8% 작게 나타났다. 전원을 연결한 후 전리계가 실제로 평형에 도달하는 시간은 20분으로 이는 전리계의 안정성 표시기보다 9분 지연되었으며 인가전압을 바꾼 경우에는 1분 이내에 평형에 도달하였다. 전리계의 누설의 측정에서 영점의 이동은 0.002(스케일)/15분이었고 10분 조사 후 영점의 이동은 발견되지 않았다. 전리계는 3개월 동안 99.4%의 안정성을 유지하였다. 스케일 영역 0.000-9.991 에서 전리계의 선형성에서의 이탈은 0.9% 이었다. 온도 범위 17 - 34 $^{\circ}C$ 에서 전리계의 영점이동은 0.2% 이내였다. 본 연구에서는 임상에서 사용하고 있는 전리계에 대한 성능을 평가하는 항목을 제시하고 이를 전리계의 정도관리에 이용하도록 하였다. 이러한 프로그램의 운용을 통하여 전리계에 의한 오차를 줄임으로써 방사선측정에서의 정확도와 정밀도를 향상시킬 수 있을 것으로 사료된다.

  • PDF

용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가 (The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy)

  • 이동형;배선명;곽정원;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.77-85
    • /
    • 2013
  • 목 적: 용적변조회전 방사선치료는 겐트리 회전과 다엽콜리메이터, 선량률이 연동되어 진행되며 치료 중 선량 전달의 중단이 발생한 경우 겐트리와 다엽콜리메이터가 최초위치부터 다시 동작하여 정지된 지점부터 선량전달이 재개된다. 본 연구는 용적 변조회전 방사선치료의 치료 중단과 재 진행에 따른 선량전달의 오차를 분석하고자 하였다. 대상 및 방법: 10명의 환자를 대상으로 전산화치료계획시스템(Eclipse V10.0, Varian, USA)을 이용하여 용적변조회전 방사선 치료 계획을 수립하였다. TRILOGY (Varian, USA)의 6 MV 선속을 이용하여 계획된 선량을 이차원 배열 검출기와 CUBE (IBA dosimetry, Germany)팬텀에 조사하였다. OmniPro I'mRT system (V1.7b, IBA dosimetry, Germany)을 통해 4회에 걸쳐 일반적인 선량전달의 일관성을 평가 하고 선량 전달의 중단 또는 도어 인터락 발생으로 인해 선량 전달이 중단되고 최초지점부터 다시 시작되어 조사되는 경우와 비교하여 감마지수(Gamma index)의 변화를 분석하였다. 결 과: 선량 전달이 정상적으로 이루어진 경우에 각각의 감마 평균 신호 값의 차이는 0.1로 나타났고, 선량 전달의 중단이 발생한 경우 0.128로 나타났으며 도어 인터락의 경우 0.141로 나타났다. 각각의 경우 감마 표준편차 값의 차이는 0.071, 0.091, 0.099로 나타났고, 감마 최대값의 차이는 0.286, 0.379, 0.413으로 나타났다. Gamma pass rate (3%, 3 mm)는 허용 오차 범위를 만족하였고, T검증 결과 95% 신뢰구간에서 P-value가 0.05 미만으로 유의한 차이를 보였다. 결 론: 본 실험에서 치료 중 선량 전달의 중단 및 재시작에 관한 정확성을 평가해 본 결과 통계적으로는 차이가 있으나 임상적으로 허용 오차 범위이내로 문제가 없다는 것을 알 수 있었다. 그러나 겐트리와 다엽콜리메이터, 선량률의 연동으로 정확성이 요구되는 치료방법인 만큼 선량적인 측면에서 치료 중단에 따른 차이는 간과할 수 없다. 그러므로 갑작스러운 치료 중단 상황이 발생한 경우 추가적인 정도관리 절차를 통해 정확한 선량평가가 이루어져야 할 것으로 사료된다.

  • PDF