• 제목/요약/키워드: Dosimetric Verification

검색결과 32건 처리시간 0.028초

6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구 (A Study on Design and Application of Tissue Compensator for 6MV X-rays)

  • 채규영;최은경;정웅기;강위생;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인 (The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.3-17
    • /
    • 1996
  • 방사선 치료분야에서 선량 보상체가 널리 이용되고 있으나, 그 보상효과에 대한 확실한 검증 방법은 알려진 바가 거의 없다. 본 연구에서는 Missing Tissue 뿐 아니라, Internal Tissue Inhomogeneity 까지 고려한 3차원 보상체를 제작하고, Exit Beam Dose Profile의 측정값과 본 연구에서 고안한 방법으로 기대값을 구해 비교함으로써 보상체의 성능을 평가하고자 하였다. 환자정보는 CT Simulator를 사용하여 얻었고, 보상체 정보는 Render Plan 3-D Planning System을 통해 얻었다. Computer Controlled Milling Machine으로 알루미늄 보상체를 제작해서 보상체가 있는 경우와 없는 경우의 선량 프로파일을 측정하여 비교하였다. 측정은 폴리스티렌 팬톰 사이에 필름을 삽입하여 팬톰 내에서의 실제 선량 분포를 구하고, 필름 카셋트를 이용해서 Exit Beam Dose Profile 을 동시에 얻었다. Oblique Beam, Parallel Opposing Beam, Inhomogeneus Human Phantom에 대해 제작된 보상체가 각각 선량보상 효과가 잘 나타남을 볼 수 있었고, 이 연구에서의 성능확인 방법을 통해 보상체의 성능을 확인할 수 있었다.

  • PDF

방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법 (In Vivo Dosimetry with MOSFET Detector during Radiotherapy)

  • 김원택;기용간;권수일;임상욱;허현도;이석;권병현;김동원;조삼주
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.17-23
    • /
    • 2006
  • 생체내선량측정법(In vivo dosimetry)은 방사선치료 시 선량학적 오차 및 치료장비의 비정상적인 작동을 검출할 수 있는 환자 치료검증방법이다 본 연구에서는 생체내선량측정법 중 환자 체표면에 선량계를 부착하여 환자 치료와 동시에 치료 검증을 할 수 있는 체표면선량측정법을 연구하였다. 이를 위해 선량 재현성 및 방향성이 우수한 MOSFET 검출기를 이용하였다. 선량 검증의 유용성 평가를 위해 치료계획장비의 치료계획검증기능을 이용하여 선량측정지점의 전달선량을 획득하였으며, 이를 MOSFET 검출기의 측정 결과와 비교 분석하였다. 그 결과 MOSFET 검출기의 교정값 및 재현성은 제작사가 제시한 기준값에 대해 ${\pm}2%$ 이내에서 일치하였고, 각 환자에서의 체표면선량측정값은 치료계획에서 얻은 값과 ${\pm}5%$이내에서 일치함을 알 수 있었다. 기존의 전리함과 다이오드 검출기를 사용한 체표면선량측정법은 단순한 치료기법에만 한정하여 사용할 수 있었다. 그러나 본 연구에서 이용한 MOSFET 검출기는 복잡한 방사선치료기법(3 dimensional radiotherapy, intensity modulated radiotherapy)에서 치료계획상의 전달선량을 환자 체표면에서 직접적으로 측정할 수 있어 임상적용의 유용함을 알 수 있었다.

  • PDF

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

유방암의 접선 세기조절 방사선치료 선량 특성 분석 (Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy)

  • 윤미선;김용협;정재욱;남택근;안성자;정웅기;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.219-228
    • /
    • 2012
  • 기존의 쐐기(wedge) 필터를 사용하는 접선조사(tangential irradiation) 방식의 일반적인 유방암 방사선치료와 동일한 접선 조사야(filed)를 사용하면서 쐐기 필터를 삽입하는 대신 다엽콜리메터의 움직임을 통해 치료부위의 선량분포를 균일하게 형성토록 하는 접선 세기조절 방사선치료(tangential breast Intensity modulated radiotherapy, T-B IMRT)가 유방암치료에 적용되고 있다. 본 연구에서는 T-B IMRT치료계획에서 계산된 선량분포를 기존의 쐐기 필터를 사용한 일반적인 접선조사 방식의 치료계획과 비교하여 치료표적 및 중요장기에서의 선량분포 측면에서 T-B IMRT의 타당성을 살펴보고, 실제 T-B IMRT치료 빔 조사 시 선량 측정 및 치료계획 결과와의 오차 분석을 통해 선량 분포의 정확도를 확인하고자 하였다. 기존의 쐐기필터를 이용한 접선조사 방식으로 치료한 유방암 환자 15명을 대상으로 T-B IMRT치료계획을 세운 후, 계산된 선량분포를 비교, 분석하였다. T-B IMRT치료계획에서 치료표적 부피 내 선량분포의 균일도가 기존의 쐐기를 사용한 접선조사 방식보다 향상된 결과를 보였으며, 주변의 정상조직과 중요장기의 선량을 상대적으로 줄일 수 있음을 확인할 수 있었다. T-B IMRT의 실제 치료조사 시 선량정확도를 분석하기 위해 적합한 팬텀을 사용하여 품질보증(QA) 치료계획을 수립하였다. 원기둥 형태의 아크릴에 이온전리함을 삽입한 형태의 팬텀을 사용하여 치료계획과 실제 치료 빔 조사를 통해 측정된 절대선량 값을 비교하였으며, 평균 오차는 $0.7{\pm}1.4%$로 분석되었다. 이차원 다이오드 검출기 배열장치를 이용한 선량분포의 정확도 분석에서는 치료계획 시 계산된 선량분포와 실제 측정된 선량분포의 gamma evaluation (3%, 3 mm 기준)를 통해 평균 $97.3{\pm}2.9%$의 합격률(pass rate)로 타당성 있는 정확도를 보여주었다. 본 연구를 통해 선량분포 측면에서 기존 쐐기필터를 이용한 접선 조사방식의 방사선치료 대비 T-B IMRT의 장점을 확인할 수 있었고, T-B IMRT에 적합하게 수립된 품질보증 과정을 통해 실제 조사되는 선량의 정확도를 확인할 수 있었다.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

입체조형 동적회전조사 방사선치료의 선량 검증 (Dosimetric Verification of Dynamic Conformal Arc Radiotherapy)

  • 김태현;신동호;이두현;박성용;윤명근;신경환;표홍렬;김주영;김대용;조관호;양대식;김철용
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.166-175
    • /
    • 2005
  • 입체조형 동적회전조사 방사선치료(Dynamic Conformal Arc Radiotherapy, DCAR)에서 필름 선량계를 이용한 선량검증시 필름 회전중심점 이동 보정값을 최적화법으로 구하고 최적화 후 DCAR에 대한 선량 검증의 정량적 허용기준을 제시하고자 하였다. 정위방사선치료를 시행했던 7명의 전이성 뇌암 환자에서 DCAR 치료계획을 시행하고 필름 선량계로 선량을 측정하였다. 필름 선량계의 가장 큰 계통적 오차 요인인 회전중심점 이동 보정값을 최적화법으로 구하고 치료계획과 필름으로 측정된 선량분포를 비교하여 최적화 전후의 평균 선량오차와 점선량오차가 $5\%$ 이상인 지점의 비율을 얻었다. 모든 환자에서 필름 선량계의 회전중심점 이동 보정값은 1 mm 이내였다. 필름 회전중심점 이동 보정 최적화전, 후로 선량오차 결과를 산출하였다. 최적화 전, 후의 평균 선량오차의 평균은 각각 $1.70{\pm}0.36\%$, $1.34{\pm}0.20\%$이었고 점선량오차가 $5\%$ 이상인 지점 비율의 평균은 각각 $4.54{\pm}3.94\%$, $0.11{\pm}0.12\%$로서 최적화 후 선량오차가 현저히 감소하였다. 본 연구의 결과와 같이 최적화법을 이용한 필름의 회전중심점 이동값을 구하고 최적화 후의 평균 선량오차와 점선량오차가 $5\%$ 이상인 지점의 비율을 구하는 방법은 임상에서 DCAR에 대한 선량 검증 방법으로 유용하게 사용될 수 있을 것으로 기대된다.

  • PDF