Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
The Korean Journal of Nuclear Medicine Technology
/
v.13
no.3
/
pp.10-16
/
2009
Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.
Sung, Sang Yeop;Lee, Yu-Mi;Kim, Sang Hoon;Ha, Bo-Geun;Kang, Si-Yong;Kim, Jin-Baek;Kim, Dong Sub
Horticultural Science & Technology
/
v.31
no.4
/
pp.490-495
/
2013
Two chrysanthemum varieties, 'ARTI-purple' and 'ARTI-queen', were chronically irradiated with doses of 30, 50, 70, and 100 Gy for four weeks in gamma-phytotron, a long term irradiation facility. We investigated the growth, responses of antioxidant enzymes (ascorbate peroxidase, APX; catalase, CAT; peroxidase, POD; superoxidase dismutase, SOD) and malondialdehyde (MDA) contents under different doses of chronic-irradiation. The five plant growth measurements including plant height, number of leaves, internode length, stalk diameter and leaf thickness were investigated immediately after four week irradiation. The plant height (p<0.001), internode length (p<0.01), the number of leaves (p<0.001) and stalk diameter (p<0.05) were significantly decreased an increasing doses of gamma-ray. Among them, especially, the internode length was remarkably decreased showing the RD50 (Reduction Dose 50) at approximately 65 Gy. The antioxidant response after four weeks of recovery period, ascorbate peroxidase (APX) (p<0.01), superoxide dismutase (SOD) (p<0.01) and peroxidase (POD) (p<0.001) were significantly increased with an increasing dose of gamma-ray. And malondialdehyde (MDA) (p<0.01) contents showed the significant increase at the 70 and 100 Gy which means the oxidative stress was lasting for a considerable period. In this study, the 50 Gy irradiation as optimal dose showed higher growth than the $RD_{50}$, it also showed insignificant differences on the antioxidant responses and MDA contents. However, the 100 Gy dose showed lower growth than $RD_{50}$.
This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.
Park, Young-Bae;Jung, Yong-Jun;Choi, Jeong-Hak;Moon, Boung-Hyun
Journal of Environmental Science International
/
v.23
no.5
/
pp.903-910
/
2014
This study examined the treatment characteristics of hard-to-degrade pollutants such as TCE which are found in organic solvent and cleaning wastewater by nZVI that have excellent oxidation and reduction characteristics. In addition, this study tried to find out the degradation characteristics of TCE by Fenton-like process, in which $H_2O_2$ is dosed additionally. In this study, different ratios of nZVI and $H_2O_2$, such as 1.0 mM : 0.5 mM, 1.0 mM : 1.0 mM, and 1.0 mM : 2.0 mM were used. When 1.0 mM of nZVI was dosed with 1.0 mM of $H_2O_2$, the removal efficiency of TOC was the highest and the first order rate constant was also the highest. When 1mM of nZVI was dosed with 0.5 mM of $H_2O_2$, the first order rate constant and removal efficiency were the lowest. The size of first order rate constant and removal efficiency was in the order of nZVI 1.0 mM : $H_2O_2$ 1.0 mM > nZVI 1.0 mM : $H_2O_2$ 2.0 mM > nZVI 1.0 mM : $H_2O_2$ 0.5 mM > $H_2O_2$ 1.0 mM > nZVI 1.0 mM. It is estimated that when 1.0 mM of nZVI is dosed with 1.0 mM of $H_2O_2$, $Fe^{2+}$ ion generated by nZVI and $H_2O_2$ react in the stoichiometric molar ratio of 1:1, thus the first order rate constant and removal efficiency are the highest. And when 1.0 mM of nZVI is dosed with 2.0 mM of $H_2O_2$, excessive $H_2O_2$ work as a scavenger of OH radicals and excessive $H_2O_2$ reduce $Fe^{3+}$ into $Fe^{2+}$. As for the removal efficiency of TOC in TCE by simultaneous dose and sequential dose of nZVI and $H_2O_2$, sequential dose showed higher first order reaction rate and removal efficiency than simultaneous dose. It is estimated that when nZVI is dosed 30 minutes in advance, pre-treatment occurs and nanoscale $Fe^0$ is oxidized to $Fe^{2+}$ and TCE is pre-reduced and becomes easier to degrade. When $H_2O_2$ is dosed at this time, OH radicals are generated and degrade TCE actively.
The purpose of this study is to investigate whether gold nanoparticles had radiosensitization when combined with gamma and x ray beam. Cytotoxicity was mearsured with comparing survival fraction after incubated time 6,12,18 and 24 hours. Clonogenic assay was employed to assess survival fraction of cells with and without gold nanoparticles treatment following gamma ray irradiation. The most of gold nanoparticles were distributed in the cytoplasm. And the toxicity of gold nanoparticles used this study were found to be non-cytotoxic. And we also observed enhancement by about 40% in RBE value for gamma ray irradiation of cells treated with gold nanoparticles. Dose reduction of about half for gamma ray irradiation is demonstrated for gold nanoparticles treated cells as compared to untreated cells. In cells with exposed to gamma ray, DNA damage was increased when compared to only radiation exposed cells. The study revealed a significant reduction in radiation dose for killing the cells with internalized gold nanoparticles as compared to the cells without gold nanoparticles. The gold nanoparticles treatment resulted in enhancement of radiation effect as evident from increase in relative biological effectiveness values for photon irradiated cells.
Journal of the Korean Society of Food Science and Nutrition
/
v.35
no.1
/
pp.104-108
/
2006
Effect of gamma irradiation on the softening of dried fernbrake at different moist-heating conditions was investigated. Dried fernbrake packaged in controlled atmosphere $(CO_2\;25\%,\;N_2\;75\%)$ was irradiated up to 7 kGy with $\gamma-ray$. Hardness of dried fernbrake was significantly decreased at the irradiation dose of above 5 kGy. Hardness of cooked fernbrake was significantly decreased with increasing irradiation dose level as well as heating temperature and time. $DT_{50}$ value (The heating time required to reach the $50\%$ reduction of hardness) for irradiated fernbrake was shortened according to dose level as well as heating temperature and heating time: $DT_{50}$ value of control: 23 min, 5 or 7 kGy: $2.2\~5.0$ min at $60^{\circ}C$. Also, the activation energy for softening of irradiated fernbrake ($1.85\~1.88$ kcal/mole for $5\~7kGy$) decreased compared to control (4.30 kcal/mole). Moisture content, swelling and rehydration rate of gamma irradiated fernbrake during moist heating increased according to the irradiation doses. Sensory results showed that scores of off-flavor and odor in irradiated fernbrake upto 7 kGy were not significantly different from control. Based on these results, gamma irradiation was effective for the reduction of cooking time and the activation energy for softening of dried fernbrake with increasing dose levels.
Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
Korean Journal of Radiology
/
v.22
no.11
/
pp.1777-1785
/
2021
Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.
This study was undertaken to determine whether the anabolic steroid nandrolone phenylpropionate(NPP) can inhibit the muscle atrophy and reduction in muscle protein synthesis caused by glucocorticoids in female rates. Daily injections of 50mg/kg of corticosterone for eight days induced significant reductions in body weight gain and protein without affecting food intake. The mass, protein and RNA content, ratio of RNA to protein, and fractional rate of protein synthesis, measured in vivo, of gastrocnemius muscle were all significantly reduced by corticosterone treatement. Simultaneous administration of NPP at a dose of 10mg/kg with corticosteorne (50mg/kg) fully inhibited the reductions in the mass, protein and RNA content of gastrocnemius muscle, and body weight gain and protein with no alteration in food intake but the reduction in fractional rate of muscle protein syntheis was only partially prevented. The results indicate that the anabolic steroid nandrolone phenylpropionate is capable of preventing muscle atrophy in female rats treated with excess corticosterion.
5 MeV proton-irradiation with total dose of $10^{15}/cm^2$ was performed on AlGaN/GaN-on-Si high electron mobility transistors (HEMTs) with various gate metals including Ni, TaN, W, and TiN to investigate the degradation characteristics. The positive shift of pinch-off voltage and the reduction of on-current were observed from irradiated HEMTs regardless of a type of gate materials. Hall and transmission line measurements revealed the reduction of carrier mobility and sheet charge concentration due to displacement damage by proton irradiation. The shift of pinch-off voltage was dependent on Schottky barrier heights of gate metals. Gate leakage and capacitance-voltage characteristics did not show any significant degradation demonstrating the superior radiation hardness of Schottky gate contacts on GaN.
This study investigated the antioxidant effects of ginseng coffee in L6 muscle cells. Ginseng coffee was prepared by coating and digesting coffee beans with ginseng concentrate. The ginseng coffee water extract potently protected against hydrogen peroxide-induced L6 cell death and adenosine triphosphate reduction in a dose-dependent manner; in fact, these cytoprotective effects were significantly greater than those of normal coffee. However, ginseng coffee did not exhibit significant radical scavenging or catalase-like activity. These results suggest that ginseng coffee might act as a cytoprotective agent in muscles, but that the protective effects are not due to a direct radical-reduction property but rather to another intracellular signaling factor.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.