• 제목/요약/키워드: Dose profile

검색결과 375건 처리시간 0.025초

Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

의료영상 데이터에서의 피폭선량 표시 방법에 관한 고찰: DICOM 표준을 중심으로 (Study on Radiation Dose in the Medical Image Data Display Method - Focused on the DICOM Standard)

  • 김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.483-489
    • /
    • 2015
  • 현대의 의료용 방사선 발생장치는 영상을 저장하고 전송하기 위해 의료영상 표준규격으로 Digital image communications in medicine(DICOM)을 채택하고 있다. DICOM 규격에서는 피폭선량 정보 표시를 위해 DICOM dose Structured Report(DICOM dose SR)를 표준으로 제정하여 사용하고 있다. 이와 더불어 DICOM Modality Performed Procedure Step(DIOCM MPPS) 정보와 DICOM tag 정보에서도 부분적인 피폭선량 정보를 표시하고 있다. 본 연구에서는 DICOM과 관련된 피폭선량정보 표시방법에 대해 고찰하고 의료정보 시스템간의 상호연동 테스트를 위한 Integrating the Healthcare Enterprise(IHE)의 Radiation Exposure Monitoring(REM) 프로파일에 대해 살펴보았다. 의료기관에서 의료방사선피폭선량정보에 대한 품질관리를 위해서는 DICOM 정보에서 표시되는 피폭선량 정보형식에 대한 이해가 반드시 수반되어야 하고 장비도입 단계에서 관련 규격에 대한 검토가 이루어져야 한다.

6MV Photon Beam Commissioning in Varian 2300C/D with BEAM/EGS4 Monte Carlo Code

  • Kim, Sangroh;Jason W. Sohn;Cho, Byung-Chul;Suh, Tae-Suk;Choe, Bo-Yong;Lee, Hyoung-Koo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.113-115
    • /
    • 2002
  • The Monte Carlo simulation method is a numerical solution to a problem that models objects interacting with other objects or their environment based upon simple object-object or object-environment relationships. In spite of its great accuracy, It was turned away because of long calculation time to simulate a model. But, it is used to simulate a linear accelerator frequently with the advance of computer technology. To simulate linear accelerator in Monte Carlo simulations, there are many parameters needed to input to Monte Carlo code. These data can be supported by a linear accelerator manufacturer. Although the model of a linear accelerator is the same, a different characteristic property can be found. Thus, we performed a commissioning process of 6MV photon beam in Varian 2300C/D model with BEAM/EGS4 Monte Carlo code. The head geometry data were put into BEAM/EGS4 data. The mean energy and energy spread of the electron beam incident on the target were varied to match Monte Carlo simulations to measurements. TLDs (thermoluminescent dosimeter) and radiochromic films were employed to measure the absorbed dose in a water phantom. Beam profile was obtained in 40cm${\times}$40cm field size and Depth dose was in 10cm${\times}$10cm. At first, we compared the depth dose between measurements and Monte Carlo simulations varying the mean energy of an incident electron beam. Then, we compared the beam profile with adjusting the beam radius of the incident electron beam in Monte Carlo simulation. The results were found that the optimal mean energy was 6MV and beam radius of 0.1mm was well matched to measurements.

  • PDF

Effect of Low Dose γ-Irradiation on the Fate and Cell Envelope of Bacillus cereus, Escherichia coli, and Salmonella Typhimurium

  • Mtenga, Adelard B.;Kassim, Neema;Lee, Won-Gyeong;Heo, Rok-Won;Shim, Won-Bo;Yoon, Yohan;Chung, Duck-Hwa
    • 한국축산식품학회지
    • /
    • 제31권6호
    • /
    • pp.843-850
    • /
    • 2011
  • This study investigated the effect of low dose ${\gamma}$-irradiation on the damage of the cell envelopes and antibiotic sensitivity profiles of Bacillus cereus, Escherichia coli, and Salmonella Typhimurium. The bacteria suspension in tryptic soy broth was exposed to the ${\gamma}$-irradiation doses of 0, 1, 1.5, 3, and 5 kGy, and then stored at $0^{\circ}C$ for 24 h. A viability test, an antimicrobial sensitivity profile, and an electron microscopy were performed to observe the effects due to ${\gamma}$-irradiation treatment. B. cereus could survive the ${\gamma}$-irradiation up to 5 kGy while E. coli and S. Typhimurium were all deactivated at 1.5 kGy and 5 kGy, respectively. At 5 kGy, the cell count of B. cereus was significantly reduced, and the survived bacteria cells retained their important features. There were no significant changes observed in the antimicrobial sensitivity profile (p>0.05) for the recovered bacteria after irradiation treatment. Low dose ${\gamma}$-irradiation below 3 kGy was found to be insufficient to achieve decontamination of B. cereus and S. Typhimurium. Cell envelope damage and deactivation of different bacteria did not occur in the same manner; thus, deferent doses of ${\gamma}$-irradiation may be required for deactivation of different bacteria.

Comparison of Piroxicam Pharmacokinetics and Anti-Inflammatory Effect in Rats after Intra-Articular and Intramuscular Administration

  • Park, Chan Woong;Ma, Kyung Wan;Jang, Sun Woo;Son, Miwon;Kang, Myung Joo
    • Biomolecules & Therapeutics
    • /
    • 제22권3호
    • /
    • pp.260-266
    • /
    • 2014
  • This study evaluated the pharmacokinetic profile and therapeutic efficacy of piroxicam (PX), a long acting non-steroidal anti-inflammatory drug for the treatment of arthritis, following intra-articular (IA) injection in comparison to the pharmacokinetic profile and therapeutic efficacy of PX after intramuscular (IM) injection. In the pharmacokinetic study in rats, systemic exposure and pharmacokinetic parameters of PX after a single IA dose were compared with systemic exposure and pharmacokinetic parameters of PX after administration of the same dose IM (0.6 mg/kg). The anti-inflammatory and analgesic effects of IA PX were evaluated simultaneously in a monoiodoacetate-induced osteoarthritis rat model. The plasma PX concentration rapidly rose following IA injection, and it was comparable to the plasma PX concentration following IM injection, suggesting the rapid efflux of the drug molecule from the joint cavity. However, in the efficacy study, the IA PX administration significantly reduced the knee swelling by reducing the level of prostaglandin $E_2$ in the joint, compared to that following administration of IA vehicle and after administration of the IM PX dose. In addition, we found that the anti-inflammatory and anti-nociceptive efficacies of IA PX were synergistically increased upon co-treatment with hyaluronic acid (HA), a potent agent for the treatment of osteoarthritis, at the weight ratio of 1:1 or 1:2, and these effects were more pronounced than those following administration of HA or PX alone. In conclusion, this study demonstrated the efficacy of the IA use of PX alone and/or in combination with HA in osteoarthritis.

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

Toxicogenomics Study on ${\alpha}-Naphthylisothiocyanate\;(ANIT)$ Induced Hepatotoxictiy in Mice

  • Hwang, Ji-Yoon;Lim, Jung-Sun;Jeong, Sun-Young;Park, Han-Jin;Cho, Jae-Woo;Yoon, Seok-Joo
    • Molecular & Cellular Toxicology
    • /
    • 제2권1호
    • /
    • pp.48-53
    • /
    • 2006
  • [ ${\alpha}-Naphthylisothiocyanate$ ] (ANIT) induces intrahepatic cholestasis, involving damage to biliary epitheial cells. This study investigates hepatic gene expression and histopathological alterations in response to ANIT treatment in order to elucidate early time response of ANIT-induced hepatotoxicity. ANIT was treated with single dose (3, 6, and 60 mg/kg) in corn oil by oral gavage. Serum biochemical and histopathological observation were performed for evaluation of hepatotoxicity level. Affymetrix oligo DNA chips were used for gene expression profile by ANIT-induced hetpatoxicity. Hepatic enzyme levels (ALT, AST, and ALP) were increased in 24 hr high dose group. In microscopic observations, moderate hepatocellular necrosis, were confirmed 24 hr high dose groups. We found that gene expression patterns were dependent on time and dose. Our selected genes were related inflammation and immunomodulation. In this study, ANIT-induced hepatotoxicity was involved in acute phase responses and provides evidence for role of neutrophil could be mechanism associated with ANIT-mediated hepatotoxicity.

연(鉛)필터의 투과선량을 이용한 15 MV X선의 에너지스펙트럼 결정과 조직선량 비교 (Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter)

  • 최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.80-88
    • /
    • 2008
  • 최근의 방사선 치료선량 계획시스템은 대체로 커널빔을 컨볼루션하여 조직선량을 구하고 있다. 본 연구에서는 광자선 빔에 따른 심부선량과 임의의 깊이에서 프로파일 선량을 구하기 위하여 반복적 수치해석을 통해 투과 필터에 의한 감쇠선량으로부터 에너지 스펙트럼을 구성하였다. 실험은 15 MV X선(Oncor, Siemens사)과 이온선량계 0.125 cc (PTW T31010)을 이용하여 납필터를 투과한 선량을 측정하여 이루어졌다. 15 MV X선의 에너지스펙트럼은 0.25 MeV 간격으로 납필터 0.51 cm에서 8.04 cm의 감쇠선량으로 실측치와 비교하여 구하였다. 실험 연산에서 15 MV X선의 최대유량은 3.75 MeV에서 나타났으며, 평균에너지는 4.639 MeV를 보였으며, 투과선량은 평균 0.6%의 오차인 반면에 최대오차는 납두께 5 cm에서 2.5%를 보였다. 조직선량은 에너지에 크게 의존하므로, 평탄형 필터의 중심과 Tangent 0.075와 0.125인 가장자리의 에너지를 구하였으며, 각각 4.211 MeV와 3.906 MeV로 나타났다. 심부선량과 프로파일 선량은 상업화로 공급되고 있는 선량계획시스템에 중심 선속과 가장자리의 각 에너지스펙트럼을 적용하여 구하여 실측선량률과 비교하였다. 생성된 심부선량 곡선은 조사면 $6{\times}6cm^2$에서 $30{\times}30cm^2$까지 실측치와 비교한 결과 1% 이내의 거의 일치하는 값을 얻었으며, 프로파일 곡선은 $10{\times}10cm^2$에서 1% 이내의 오차를 보였으나, $30{\times}30cm^2$와 같이 큰 조사면의 얕은 깊이에서는 2%의 오차를 보였다. 따라서 투과선량을 연산으로 구한 에너지 스펙트럼이 조직선량을 평가하는 데 상당히 적은 오차범위 내에서 정량적이고 정성적으로 얻을 수 있음을 알 수 있다.

  • PDF