• Title/Summary/Keyword: Dose modification

Search Result 167, Processing Time 0.024 seconds

The Formation of Nitride and Enhancement of Mechanical Properties of Al Alloy by Nitrogen Implantation (Al합금에서 질소이온주입에 의한 질화물 형성과 기계적 특성 향상)

  • Jeong, Jae-Pil;Lee, Jae-Sang;Kim, Kye-Ryung;Choi, Byung-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • The aluminum nitride(AlN) layer on Al7075 substrate has been formed through nitrogen ion implantation process. The implantation process was performed under the conditions : 100 keV energy, total ion dose up to $2{\times}10^{18}\;ions/cm^2$. XRD analysis showed that aluminum nitride layers were formed by nitrogen implantation. The formation of Aluminum nitride enhanced surface hardness up to 265HK(0.02 N) from 150HK(0.02 N) for the unimplanted specimen. Micro-Knoop hardness test showed that wear resistance was improved about 2 times for nitrogen implanted specimens above $5\;{\times}\;10^{17}\;ions/cm^2$. The friction coefficient was measured by Ball-on-disc type wear tester and was decreased to 1/3 with increasing total nitrogen ion dose up to $1\;{\times}\;10^{18}ions/cm^2$. The enhancement of mechanical properties was observed to be closely associated with AlN formation. AES analysis showed that the maximum concentration of nitrogen increased as ion dose increased until $5\;{\times}\;10^{17}\;ions/cm^2$.

Novel reforming of pyrolized fuel oil by electron beam radiation for pitch production

  • Jung, Jin-Young;Park, Mi-Seon;Kim, Min Il;Lee, Young-Seak
    • Carbon letters
    • /
    • v.15 no.4
    • /
    • pp.262-267
    • /
    • 2014
  • Pyrolized fuel oil (PFO) was reformed by novel electron beam (E-beam) radiation, and the elemental composition, chemical bonds, average molecular weight, solubility, softening point, yields, and density of the modified patches were characterized. These properties of modified pitch were dependent on the reforming method (heat or E-beam radiation treatment) and absorbed dose. Aromaticity ($F_a$), average molecular weight, solubility, softening point, and density increased in proportion to the absorbed dose of E-beam radiation, with the exception of the highest absorbed dose, due to modification by free radical polymerization and the powerful energy intensity of E-beam treatment. The H/C ratio and yield exhibited the opposite trend for the same reason. These results indicate that novel E-beam radiation reforming is suitable for the preparation of aromatic pitch with a high ${\beta}$-resin content.

Development of a reference framework to assess stylized human intrusion scenarios using GENII Version 2 considering design features of planned near-surface disposal facility in Korea

  • Kwon, Ki Nam;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1561-1574
    • /
    • 2019
  • A standard form of six stylized human intrusion scenarios for a near-surface disposal facility (e.g. the planned Korean repository, Gyeongju Phase II) is proposed through re-categorization of totally thirty-one past cases reported in public literature. A reference assessment framework for inadvertent human intrusion is newly developed using GENII Version 2 conforming to the ICRP Publication 60 and thereafter. Calculated dose from the assessment framework is verified by comparing with hand calculation results for simplified model equations independently derived. Results from GENII Version 2 and 1.485 show inevitable differences, which is mainly attributed to the difference in the external dose assessment model. If intake dose coefficients in GENII Version 1.485 are modified, the difference can be reduced but still exist to an extent. Through deterministic and probabilistic sensitivity analysis, most affecting four parameters are derived and uncertainties of the parameters are quantified. It is expected that the reference assessment framework together with representative stylized scenarios can be used to do a human intrusion impact assessment for a specific repository using site-specific information. Especially, the past practice of human intrusion impact assessment using GENII Version 1.485 with or without modification may be replaced with the new assessment framework developed in this study.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

Clinical Results of Conservative Treatment for Interdigital Neuroma (지간 신경종에서 보존적 치료의 임상적 결과)

  • Lee, Jin-Woo;Choi, Yun-Rak;Hahn, Soo-Bong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.58-63
    • /
    • 2004
  • Purpose: The purpose of this study is to evaluate the effectiveness of low-dose gabapentin for interdigital neuroma. Metrials and Methods: Between April 2000 and June 2003, 32 patients (39 feet) with interdigital neuroma were treated with using low-dose gabapentin. Two of the 32 patients were male, and thirty were female, and the average age was 47.4 years. The follow-up was 6 to 44months (mean 15.1 months). All cases were diagnosed by physical examination and ultrasonography or MRI. Low-dose gabapentin (300-600 mg) was prescribed and shoe modification was recommended. The patients were evaluated through questionnaire. Results: Neuroma was found in twenty one cases at the third intermetatarsal space, and thirteen at the second intermetatarsal space. The sensitivity of ultrasonography was 96% and that of MRI was 79%. Overall satisfaction was rated as excellent or good by 18 cases (57%). Average pain relief ratio was 50.3%, and in 14 cases, more than 80% of pain relief was noted. Nine (28%) of 32 patients showed they had no activity restrictions, such as daily activities or work, whereas 8 (25%) had mild restrictions and 15 (47%) had major restrictions. Twelve of 15 patient with major restrictions had been treated operatively (neurectomy; 10 cases, decompression; 2 cases). One case had gastrointestinal problem. Conclusion: Low-dose gabapentin for interdigital neuroma was one of the effective conservative treatments. The operation may be preserved for patient with the persist symptoms, nevertheless the conservative treatments and use of low-dose gabapentin.

  • PDF

Effect of Transverse Magnetic Field on Dose Distribution of High Energy Electron Beam (횡방향 자기장이 고에너지 전자선의 선량분포에 미치는 영향)

  • Oh, Young Kee;Kim, Ki Hwan;Shin, Kyo Chul;Kim, Jhin Kee;Kim, Jeung Kee;Jeong, Dong Hyeok;Cho, Mun Jun;Kim, Jun Sang;Yoon, Sun Min;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.209-213
    • /
    • 2007
  • In this work we have measured the dose distribution and the percent depth dose of 20 MeV electron beam using the X-OMAT films in order to verify the effects of transverse magnetic field on high energy elecrtron beam in a phantom. The result shows about 30% increase of the percent depth dose at 4.5 cm depth under the transverse magnetic field of 1.5 Tesla at 7.5 cm depth. We have verified that these were in an agreement with other theoretical results.

  • PDF

Modification and adhesion improvement of BN interfacial layers by Post-$N^+$implantation (질소 이온주입법에 의한 BN박막의 계면구조 개선 및 밀착력 향상)

  • 변응선;이성훈;이상로;이구현;한승희;이응직;윤재홍
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.2
    • /
    • pp.158-158
    • /
    • 1999
  • The post ion implantation has been applied to modify early-grown BN layer and improve the adhesion of the BN films. The effect of ion implantation doses on microstructure and interlayer was investigated by FTIR and HRTEM. And the hardness and delamination life time of N+-implanted BN films were measured. With increasing the ion dose up to 5.0×1015atoms/㎠, the change of IR spectrum is observed. At 5.0×1016atoms/㎠, a drastic transition of cubic phase into hexagonal phase is detected. The change of microstructure of early-grown layers by ion implantation is confirmed using HRTEM. Both microhardness and delamination life time of BN films increase with ion dose. The modification model of early-grown BN layers is briefly discussed based on the displacement per atom and excess boron in the BN film induced by ion irradiation.

keV and MeV Ion Beam Modification of Polyimide Films

  • Lee, Yeonhee;Seunghee Han;Song, Jong-Han;Hyuneui Lim;Moojin Suh
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.170-170
    • /
    • 2000
  • Synthetic polymers such as polyimide, polycarbonate, and poly(methyl methacrylate) are long chain molecules which consist of carbon, hydrogen, and heteroatom linked together chemically. Recently, polymer surface can be modified by using a high energy ion beam process. High energy ions are introduced into polymer structure with high velocity and provide a high degree of chemical bonding between molecular chains. In high energy beam process the modified polymers have the highly crosslinked three-dimensionally connected rigid network structure and they showed significant improvements in electrical conductivity, in hardness and in resistance to wear and chemicals. Polyimide films (Kapton, types HN) with thickness of 50~100${\mu}{\textrm}{m}$ were used for investigations. They were treated with two different surface modification techniques: Plasma Source Ion Implantation (PSII) and conventional Ion Implantation. Polyimide films were implanted with different ion species such as Ar+, N+, C+, He+, and O+ with dose from 1 x 1015 to 1 x 1017 ions/cm2. Ion energy was varied from 10keV to 60keV for PSII experiment. Polyimide samples were also implanted with 1 MeV hydrogen, oxygen, nitrogen ions with a dose of 1x1015ions/cm2. This work provides the possibility for inducing conductivity in polyimide films by ion beam bombardment in the keloelectronvolt to megaelectronvolt energy range. The electrical properties of implanted polyimide were determined by four-point probe measurement. Depending on ion energy, doses, and ion type, the surface resistivity of the film is reduced by several orders of magnitude. Ion bombarded layers were characterized by Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), XPS, and SEM.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Radiation Dose Accuracy 81 the Isocenter : Standard Stereotactic Radiosurgery Technique Developed at Seoul National University Hospital (서울대학교병원형 방사선수술 표준기법의 중심점 선량의 오차)

  • Shin Seong Soo;Kim Il Han;Ha Sung Whan;Park Charn Il;Kang Wee-Saing;Hur Sun Nyung
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.391-395
    • /
    • 2002
  • Purpose : To confirm the accuracy of the radiation dose at the isocenter by the standard linear accelerator-based stereotactic radiosurgery technique which was developed at Seoul National University Hospital. Materials and Methods : Radiation dosimetry was undertaken during standard 5-arc radiosurgery using 6 MV X-ray beam from CL2100C linac. The treatment head was attached with circular tertiary collimators of 10 and 20 mm diameter. We measured the absorbed dose at the isocenter of a multi-purpose phantom using two kinds of detector : a 0.125 co ionization chamber and a silicon diode detector. Results : The dose differences at each arc plane between the planned dose and the measured dose at the isocenter raged from $-0.73\%\;to\;-2.69\%$ with the 0.125 cc ion chamber, and from $-1.29\%\;to\;-2.91\%$ with the diode detector during radiosurgery with the tertiary collimator of 20 mm diameter. Those with the 10-mm tertiary collimator ranged from $-2.39\%\;to\;-4.25\%$ with the diode. Conclusion : The dose accuracy at the isocenter was ${\pm}3\%$. Therefore, further efforts such ws modification in processing of the archived image through DICOM3.0 format are required to lessen the dose difference.