• Title/Summary/Keyword: Dose dependence

Search Result 173, Processing Time 0.031 seconds

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

Inducing Effects of Rubus coreanus on Cell Death and Apoptotic Gene Expressions in Human Breast Cancer Cells (복분자의 유방암 세포 사멸 및 사멸 유전자 발현 유도 효과)

  • Kim, Hee-Jung;Kang, Keum-Jee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.6
    • /
    • pp.723-732
    • /
    • 2013
  • We investigated the inducing effects of Rubus coreanus extract (RCE) on apoptosis and its related gene expressions in human breast cancer cells. MDA-MB-231 cells were cultured in the presence of 0, 200, 300, and $400{\mu}g/mL$ RCE for 24h. MTT assay demonstrated that relative cell viability measured a decrease in a dose-dependent manner (p<0.05). This dependency was also found in the increasing levels of cell death by a dual staining with Hoechst 33322 and propidium iodide (p<0.05). These close associations was also observed by different stages of apoptotic processes, as shown by an Apoptosis Detection Kit. To determine whether the alterations in such cell activities obtained above cause the induction of apoptotic genes, PT-PCR was performed expressions of both Bcl-2 and Bax mRNAs. The Bcl-2/Bax ratio which is an important indicator of apoptosis, was found to have significantly decreased dose dependence (p<0.05). Western blot analysis also demonstrated that Caspase-3 significantly increases in a dose-dependent manner (p<0.05) in addition to similar alterations of other proteins examined. Taken these results together, the ethanolic RCE used induces a reduction in cell viability along with increased membrane permeability. This leads to a precautious apoptotic process and, subsequently, cell death through the apoptotic pathway involving Bax and Caspase-3 in human breast cancer MDA-MB-231 cells.

Influence of Gamma Irradiation on Greening of Mung Bean Seedlings

  • Kim, Jin-Hong;Moon, Yu-Ran;Kim, Jae-Sung;Lee, Min-Hee;Lee, Seung-Sik;Chung, Byung-Yeoup
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • Ionizing radiation causes many alterations in photosynthetic machineries. However, there is no information about effects of ionizing radiation on the development of photosynthetic machineries in plants. We investigated the greening of etiolated mung bean seedlings after gamma-irradiation of 50 to 300 Gy. The irradiation inhibited seedling growth with great dependence on the radiation dose. In particular, growth of stems was more affected than that of hypocotyls. Irradiated leaves showed inhibition in growth, aberration in morphology, and yellowing in color depending on the radiation dose. Contents of photosynthetic pigments such as chlorophylls and carotenoids were significantly decreased in the irradiated leaves. The apparent electron transport rate for photosynthesis, ETR, was similarly changed depending on the radiation dose. However, the maximal photochemical efficiency of Photosystem II (PSII), Fv/Fm, was little affected by the irradiation. Moreover, the 50-Gy seedlings maintained the control level of light saturating for photosynthesis and showed slightly higher Fv/Fm values in spite of significant decreases in the photosynthetic pigment content and ETR. These results suggest that the inhibition of the overall photosynthetic capacity couldn’t be causally relatqaed with the repression in the initial development of irradiated seedlings and that the overall photosynthetic machineries can develop and work to some extent as a concerted system for photosynthesis even after exposure to acute doses of ionizing radiation.

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Radiation-Induced Apoptosis of Lymphocytes in Peripheral Blood (말초혈액 내 림프구의 방사선에 의한 아포프토시스)

  • Oh, Yoon-Kyeong;Lee, Tae-Bum;Nam, Taek-Keun;Kee, Keun-Hong;Choi, Cheol-Hee
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • Purpose : This study quantitatively evaluated the apoptosis In human peripheral blood lymphocytes using flow cytometry, and investigated the possibility of using this method, with a small amount of blood, and the time and dose dependence of radiation-induced apoptosls. Materials and Methods : Peripheral blood lymphocyes were isolated from the heparinized venous blood of 11 healthy volunteers, 8 men and 3 women, with each 10 ml of blood being divided Into IS samples. The blood lymphocytes were Irradiated using a linear accelerator at a dose rate of 2.4 Gy/min, to deliver doses of 0.5, 1, 2 and S Gy. The control samples, and Irradiated cells, were maintained in culture medium for 24, 48 and 72 hours fellowing the Irradiation. The number of apoptotic cells after the in vitro X-irradiation was measured by flow cytometry after Incubation periods of 24, 48 and 72 hours. We also observed the apoptotic cells using a DNA fragmentation assay and electron microscopy. Results : The rate oi spontaneous apoptosis increased in relation to the time interval following irradiation (1.761 ${\pm}$0.161, 3.563${\pm}$0.554, 11.098${\pm}$2.849, at 24, 48, and 72 hours). The apoptotli cells also increased In the samples irradiated with 0.5, 1, 2 and 5 Gy, In a radiation dose and time interval after Irradiation manner, with the apoptosls being too great at 72 hours after Irradiation. The dose-response curves were characterized by an Initial steep Increase In the number of apoptotic cells for Irradiation doses below 2 Gy, with a flattening of the curves as the dose approached towards 5 Gy. Conclusion :The flow cytometric assay technique yielded adequate data, and required less than 1 mL of blood. The time and dose dependence of the radiation-induced apoptosis, was also shown. It is suggested that the adequate time Interval required for the evaluation of apoptosis would be 24 to 48 hours after blood sampling.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Effect of Houttuynia cordata on EtOH-induced Lipidperoxidation in Rat (알콜유도 지질과산화에 미치는 어성초 영향)

  • Kang Tak-Lim
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.2 no.1
    • /
    • pp.45-54
    • /
    • 1998
  • The antilipidperoxidative and hepatopreventive effects of Houttuynia cordata extract(HCE) were investigated at the level of liver homogenates and serum of SD rats intoxicated EtOH(3g/kg for 3days). We measured MDA(malondialdehyde) in the live. homogenate, AST(1-aspartate-2-oxoglutarate aminotransferase) and ALT( 1-alanine-2-oxoglutarate aminotransferse) in the serum. The analysis of the measurement indicated that HCE reduced MDA, ALT and AST significantly and their reduction was in relation to dose dependence. In rat liver homogenate intoxicated with EtOH, HCE treatment group inhibited lipidperoxidation by 50-75%. In rat serum intoxicated EtOH, HCE inhibited AST and ALT by 40-70%.

  • PDF

Genotoxic evaluation of recombinant human erythropoietin (rHu-EPO) in shod-term assays. (인체 재조합 적혈구 조혈인자, rHu-EPO의 유전독성 평가)

  • 김형식;곽승준;천선아;임소영;안미영;김원배;김병문;안병옥;서동상
    • Environmental Mutagens and Carcinogens
    • /
    • v.16 no.2
    • /
    • pp.103-108
    • /
    • 1996
  • The mutagenic potential of rHu-EPO was evaluated using the short-term genotoxicity tests including Ames, chromosome aberration and micronuclei tests. In Salmonella typhimurium assay, rHu-EPO did not show any mutagenic response in the absence or presence of S9 mix with TA98, TA100, TA1535, and TA1537. In chromosome aberration test, rHu-EPO did not show any significant effect on Chinese Hamster Ovary(CHO) cells compared with control. In micronucleus test using male ICR mice, a dose-dependence increase in the frequency of micronucleuted polychromatic erythrocytes(MNPCEs) was observed in bone marrow cells treated with rHu-EPO. However, it was related to the secondary effect of rHu-EPO and the number of MNPCEs was equal to spontaneous frequency. These results indicate that rHu-EPO does not show any positive response in short-term genotoxicity assays.

  • PDF

Studies on the Antilipidperoxidative Effect of Aloe (알로에의 과산화지질 억제효과에 관한 연구)

  • 하배진
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.159-164
    • /
    • 1996
  • The antilipidperoxidative and hepatopreventive effects of Aloe water extract (30 mg, 50 mg, 100 mg) were investigated at the levels of liver-total homogenates and the sera of SDrats intoxicated with CCl4 (0.5 cc/100g) and 50% ethanol. We measured MDA (Malondialdehyde) in the liver homogenate, AST (L-Aspartate-2-oxoglutarate aminotransferase) and ALT(L-Alanine-2-oxo-glutraate aminotransferase) in the serum. The analysis of the measurement indicated that Aloe water extract reduced MDA, ALT and AST significantly and their reduction was in relation to dose dependence. In rat liver homogenate intoxicated with ethanol and CCl4, Aloe treatment group markedly inhibited lipidperoxidation by 30%∼70%. In rat serum intoxicated with ethanol and CCl4, Aloe treatment group inhibited AST, ALT by 40%∼90%. In these data Aloe may be used to inhibit or prevent the hapatic toxicity with results from the environmental and alcohlic factors through the further study of its exact antihepatotoxic mechanism.

  • PDF

Polycrystalline Silicon Thin Film Transistor Fabrication Technology (다결정 실리콘 박막 트랜지스터 제조공정 기술)

  • 이현우;전하응;우상호;김종철;박현섭;오계환
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.212-222
    • /
    • 1992
  • To use polycrystalline Si Thin Film Transistor (poly-Si TFT) in high density SRAM instead of High Load Resistor (HLR), TFT is needed to show good electrical characteristics such as large carrier mobility, low leakage current, high driver current and low subthreshold swing. To satisfy these electrical characteristics, the trap state density must be reduced in the channel poly. Technological issues pertinent to the channel poly fabrication process are investigated and discussed. They are solid phase growth (SPG), Si-ion implantation, laser annealing and hydrogenation. The electrical properties of several CVD oxides used as the gate oxide of TFT are compared. The dependence of the electrical characteristics of TFT on source-drain ion-implantation dose, drain offset length and dopant lateral diffusion are also described.

  • PDF