• 제목/요약/키워드: Dose coefficients

검색결과 151건 처리시간 0.023초

ESR Spectroscopy에 의한 감마선 조사된 향신료의 확인 (Detection of Gamma-Irradiated Spices by ESR Spectroscopy)

  • 양재승;남혜선
    • 한국식품영양과학회지
    • /
    • 제30권2호
    • /
    • pp.239-242
    • /
    • 2001
  • Electron spin resonance(ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity of irradiated spices and to identify the stability of radicals after storage. Red, white and black peppers, and garlic powders were irradiated with doses of 0, 1, 5, 10, 20 and 30 kGy at room temperature using a Co-60 irradiator. Triplet ESR signals were observed in irradiated pepper powders, while singlet ESR signals were observed in irradiated garlic powders. Those characteristic signals were not detected in non-irradiated samples. The strength of ESR signals linearly increased with the applied doses(1~3 kGy). Highly positive correlation coefficients ($R^2$=0.9757~0.9933) were obtained between the irradiation doses and the corresponding ESR signal intensities. The signal intensities of irradiated samples were stable even after 97 days of storage at room temperature.

  • PDF

Uncertainty and Sensitivity Analysis on A Biosphere Model

  • Park, Wan-Sou;Kim, Tae-Woon;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • 제15권2호
    • /
    • pp.101-112
    • /
    • 1990
  • For the performance assessment of the radioactive waste disposal system (repository), a biosphere model is suggested. This biosphere model is intended to calculate the annual doses to man caused by the contaminated river water for eight pathways and four radionuclides. This model can also be applied to assess the radiological effects of contaminated well water. To account for the uncertainties on the model parameter values, parameter distributions are assigned to these model parameters. Then, Monte Carlo simulation method with Latin Hypercube sampling technique is used. Also, sensitivity analysis is performed by using the Spearman rank correlation coefficients. It is found that these methods are a very useful tool to treat uncertainties and sensitivities on the model parameter values and to analyze the biosphere model. A conversion factor is proposed to calculate the annual dose rate to humans arising from a unit radionuclide concentration in river water. This conversion factor allows for the substitution of the biosphere model in a probabilistic performance assessment computer code by one single variable.

  • PDF

Realization of Robust Performance for Interval Systems Using Model Reference Feedback

  • Okuyama, Yoshifumi;Takemori, Fumiaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.167-172
    • /
    • 1998
  • The physical parameters of controlled systems are uncertain and are accompanied with nonlinearity. The transfer function of the controlled system should, therefore, be expressed by interval polynomials. This paper describes the realization of robust performance for that type of control system (interval system) via model reference feedback. First, we will analyze an invariance problem of dynamic characteristics such that the dominant roots do not break away from a specified circular area, and will present a discrimination algorithm (i.e., a division algorithm) for the extreme points of the uncertain coefficients. Then, we will present a design method of control systems which have a robust performance such that the location of the dominant roots dose not vary excessively.

  • PDF

Differential analysis of amikacin and butirosin

  • Nam, Doo-Hyun;Ryu, D.Y.
    • Archives of Pharmacal Research
    • /
    • 제5권2호
    • /
    • pp.87-91
    • /
    • 1982
  • In order to develop an analytical method for amikacin and butirosin in presence of their parent antibiotics, kanamycin A and ribostamycin, high-performance liquid chromatographic technique and microbioassay method were evaluated and compared. Using high performance liquid chromatography, two acylated antibiotics, amikacin and butirosin was partially separated from their parent antibiotics, to provide a qualitative analytical method. In microbioassay using Pseudomonas aeruginosa TI-13, a producer of aminoglycoside-3-phosphotransferase I, only acylated antibiotics were selectively analyzed when paper disc-susceptibility assay was used. The standard curve showed a good correlation between the response and odse in semilogarithmic plat with correlation coefficients above 0.96, and analytical deviation from expected dose was within 10%.

  • PDF

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Numerical studies on the important fission products for estimating the source term during a severe accident

  • Lee, Yoonhee;Cho, Yong Jin;Lim, Kukhee
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2690-2701
    • /
    • 2022
  • In this paper, we select important fission products for the estimation of the source term during a severe accident of a PWR. The selection is based on the numerical results obtained from depletion calculations for the typical PWR fuel via the in-house code named DEGETION (Depletion, Generation, and Transmutation of Isotopes on Nuclear Application), release fractions of the fission products derived from NUREG-1465, and effective dose conversion coefficients from ICRP 119. Then, for the selected fission products, we obtain the adjoint solutions of the Bateman equations for radioactive decay in order to determine the importance of precursors producing the aforementioned fission products via radioactive decay, which would provide insights into the assumption used in MACCS 2 for a level 3 PSA analysis in which up to six precursors are considered in the calculations of radioactive decays for the fission product after release from the reactor.

골프장에 산포되는 농약의 강우유출특성과 risk assessment (Rainfall Runoff Characteristics and Risk Assessment of Agro-chemicals Used in Golf Links)

  • 조현서
    • 한국환경과학회지
    • /
    • 제4권1호
    • /
    • pp.19-28
    • /
    • 1995
  • 본 연구에서는, 골프장에서 사용되는 농약의 강우유출특성과 인테의 건강에 대한 risk assessment를 행하였다. 골프장에 살표되는 농약으니 강우시의 강우유출큭성을 모델화하여, 지표농약의 강우유출특성을 구하였다. 이 유충계수를 이용하여 하류 하천에서의 농약의 온도를 예측하여, 인체의 건강에 대한, risk를 평가하였다. 농약의 강우유출특성을 파악하기 위하여 온약이 유입되는 저정연목의 유역을 선정하여 강우시의 농약의 강우유출특성을 조사하였다. 지표농약으로 선정한 농약의 츄출계수(1/mm)는, Flutolanil가 0.0054, Isoprothiolane이 0.0019, Chlorpyrifos가 0.0003, Simazine이 0.0044 였다. 이 유출계수를 지역수계의 특성을 고려하여 설정한 지역수계모델의 재현능력을 확인하였다. 또, 이 지역수계모델을 이용하여 하류 하천에서의 농약ㅢ 농도를 예측하여 농약에 오염된 하천수를 이용하는 하류주민에 대한 건강 risk의 평가를 행하였다. 폴로경로로서는 음료수로서의 섭휘만을 고려하였으며, risk의 평가시표로서는 10% ADI(Acceptable Daily Intake) 와 VSD(Virtually Safe Dose)를 이용하였다. 인체의 건강에 대한 risk는 발암risk로서 Simazine의 경우 $10^{-7}$~$10^{-9}$로 비교적 낮은 risk수준인 것으로 판단되었다

  • PDF

고무풍선 중 니트로스아민류의 노출평가 연구 (Oral Exposure Assessment of N-Nitrosamines from Rubber Balloons in Korea)

  • 김현경;이기영
    • 한국환경보건학회지
    • /
    • 제49권4호
    • /
    • pp.210-217
    • /
    • 2023
  • Background: N-nitrosamines are carcinogenic substances often found in rubber products. They are produced when certain additives of rubber products react with nitrite in saliva or air. Exposure assessment for the proper management and communication of N-nitrosamines in rubber balloons should be carried out. Objectives: This study was conducted to determine the concentrations of N-nitrosamines in rubber balloons in the South Korean market and assess exposure among Korean children. Methods: Forty eight rubber balloon products in the domestic market were purchased and a total of 68 balloons were analyzed for N-nitrosamines and N-nitrosatable substances. Chemical analysis was conducted by HPLC-MS/MS according to the method EN 71-12. For exposure assessment, an exposure algorithm and coefficients were obtained from previous studies. Results: Among the 68 rubber balloons, N-nitrosamines were detected in 18 (26.5%) with an average level of 60.77 ㎍/kg. N-Nitrosatable substances were detected in 44 products (64.7%) with an average level of 1353.33 ㎍/kg. As a result of the exposure evaluation, the exposure dose differed according to how exposure coefficients were applied. The median exposure (50th percentile) was higher in the age group of 6~12 years, and high exposure (95th percentile) was higher in the age group of 13~18. Conclusions: We evaluated the N-nitrosamines contained in rubber balloons purchased in the domestic market and assessed oral exposure among South Korean children. For integrated risk management of N-nitrosamines, further studies and discussion regarding exposure and risk assessment are required.

GC/MS를 이용한 carteolol의 대사 및 배설연구 (Study on Metabolism and Excretion of Carteolol in Human Urine using GC/MS)

  • 민혜기;김명수;조현우;김택제;김동현;명승운
    • 분석과학
    • /
    • 제15권5호
    • /
    • pp.482-487
    • /
    • 2002
  • Carteolol은 국제올림픽위원회 (IOC)에서 금지약물로 규정하고 있는 ${\beta}$-차단제 중의 하나이다. 본 실험에서는 GC/MS를 사용하여 사람의 소변으로부터 carteolol의 복용여부를 확인하기 위한 검출방법 및 대사와 배설에 대해서 고찰하였다. 이를 위하여 효소 가수분해방법과 산 가수분해방법을 비교하여 보았는데 효소가수분해방법이 더 좋은 결과를 얻을 수 있었다. 효소 가수분해방법을 이용하여 실험한 결과 RSD 10%내외의 정밀도와 $0.05{\mu}g/m{\ell}$를 제외하고는 오차 5%이내의 좋은 정확도를 보여주었으며 회수율은 78.5%로 나타났다. Carteolol은 소변에서 대부분이 free carteolol과 conjugated carteolol로 존재하며 소량의 p-OH-carteolol로 대사됨을 알 수 있었으며 모 약물로 배출되는 양 중 conjugated form이 59.4%로 나타났다. 소변으로 배출된 carteolol의 양을 측정한 결과 복용양의 49%가 복용 후 72시간까지 모 약물로 배출됨을 알 수 있었다.

DEVELOPMENT AND EVALUATION OF A PHANTOM FOR MULTI-PURPOSE DOSIMETRY IN INTENSITY-MODULATED RADIATION THERAPY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제43권4호
    • /
    • pp.399-404
    • /
    • 2011
  • A LEGO-type multi-purpose dosimetry phantom was developed for intensity-modulated radiation therapy (IMRT), which requires various types of challenging dosimetry. Polystyrene, polyethylene, polytetrafluoroethylene (PTFE), and polyurethane foam (PU-F) were selected to represent muscle, fat, bone, and lung tissue, respectively, after considering the relevant mass densities, elemental compositions, effective atomic numbers, and photon interaction coefficients. The phantom, which is composed of numerous small pieces that are similar to LEGO blocks, provides dose and dose distribution measurements in homogeneous and heterogeneous media. The phantom includes dosimeter holders for several types of dosimeters that are frequently used in IMRT dosimetry. An ion chamber and a diode detector were used to test dosimetry in heterogeneous media under radiation fields of various sizes. The data that were measured using these dosimeters were in disagreement when the field sizes were smaller than $1.5{\times}1.5\;cm^2$ for polystyrene and PTFE, or smaller than $3{\times}3\;cm^2$ for an air cavity. The discrepancy was as large as 41% for the air cavity when the field size was $0.7{\times}0.7\;cm^2$, highlighting one of the challenges of IMRT small field dosimetry. The LEGO-type phantom is also very useful for two-dimensional dosimetry analysis, which elucidates the electronic dis-equilibrium phenomena on or near the heterogeneity boundaries.