• Title/Summary/Keyword: Dose Reduction

Search Result 1,468, Processing Time 0.032 seconds

Evaluation of Absorbed Dose according to the Use of Bolus in Opposite Breast during Radiation Therapy of Breast Cancer using VMAT (VMAT를 이용한 유방암 방사선치료 시 반대편 유방의 Bolus 사용에 따른 흡수선량 평가)

  • Kim, Jong-Bo;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.763-768
    • /
    • 2018
  • Although the development of radiation therapy techniques has made the treatment more precise, exposure by radiation is unavoidable beyond the treatment site. In this study, we wanted to evaluate the absorbed dose according to the thickness of the bolus on the opposite side of the treatment in radiation treatment for breast cancer and to analyze the effect of dose reduction. An experiment was conducted on Rando phantom using VMAT treatment methods. Five points of A, B, C, D, and E were selected for the breast opposite the treatment, and when the dosimeters of 5, 10, 15, and 20 mm were used. The highest absorbed dose at point D closest to the treatment point was measured and lowest at point B furthest from the treatment point. The mean absorbed dose was 8.61 cGy When the bolus is not used and 8.10, 7.94, 8.06, and 8.10 cGy Depending on the thickness of the bolus. In this study, bolus was intended to be used to analyze the dose-reducing effects of breasts on the other side of the treatment. The results of the study showed the effect of dose reduction and the appropriate bolus thickness should be set up to reduce the dose in normal tissues.

The reduction methods of operator's radiation dose for portable dental X-ray machines

  • Cho, Jeong-Yeon;Han, Won-Jeong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.160-164
    • /
    • 2012
  • Objectives: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Materials and Methods: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. Results: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. Conclusions: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

Disinfection of Total Coliforms in Sewage Treatment Effluent using Electron Beam (전자선을 이용한 하수처리장 방류수내 대장균군 살균)

  • Kim, Yuri;Han, Bumsoo;Kim, Jinkyu;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.376-381
    • /
    • 2004
  • The use of electron beam irradiation was investigated to disinfect total coliforms in the secondary sewage treatment effluent. Unchlorinated secondary effluent was irradiated at different dose of 0.2~1.0 kGy by 1 MeV, ELV-4 Model electron beam accelerator. It is interesting to note that a 100 % reduction in total coliforms and total colonies were achieved until a dose of approximately 0.8 kGy. Even at low dose of 0.2 kGy, the total coliforms and total colonies were successfully inactivated to the level of satisfying the new effluent discharge guideline. Besides disinfection of total coliforms, approximately a 50% removal in biochemical oxygen demand was pronounced at a dose of 0.2 kGy. More than 20 % removal in suspended solids and turbidity was also observed at a dose of 1.0 kGy. The application of electron beam irradiation appeared to be one of options to reuse sewage treatment effluent as agricultural or industrial water.

Analysis and radiation dose assessment of 222Rn in indoor air at schools: Case study at Ulju County, Korea

  • Lee, ChoongWie;Choi, Sungyeol;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.806-813
    • /
    • 2018
  • $^{222}Rn$ exists in nature in the form of a rare radioactive gas. In terms of environmental radiation, issues regarding $^{222}Rn$ have persisted because of its radiological hazardousness. Ulju County is one of the regions of Ulsan metropolitan city, with a population of 227,699. Ulju County has the highest density of industrial complexes in Korea. In this study, $^{222}Rn$ radioactivity concentration was measured and analyzed in 57 schools in Ulju County using 114 passive LR-115 type detectors to secure radiological safety and confirm basic information for reduction of resident exposure to $^{222}Rn$. The effective dose of $^{222}Rn$ was assessed to find the actual risk of the concentration surveyed in schools to human beings. The dose depended on four factors: subjects, $^{222}Rn$ concentration, dose coefficient, and time. The individuals subjected to dose estimation were classified into three types: students, teachers, and office workers. The subjects had different dwelling locations and times. The findings demonstrate that the radiological hazard to students and workers at schools in Ulju County owing to $^{222}Rn$ is negligible in terms of $^{222}Rn$ activity recommendation level.

Consideration about Radiological Technology Student's Frequent Workers Exposure Dose Rate (방사선과 재학생의 수시출입자 방사선 피폭선량에 대한 고찰)

  • Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.573-580
    • /
    • 2018
  • The Nuclear Safety Commission amended the Nuclear Safety Act by strengthening the safety management system for the frequent workers to the level of radiation workers. And students entering radiation management zones for testing and practical purposes are subject to frequent workers. It is inevitable that this will incur additional costs. In this paper, the validity of the amendment to the Nuclear Safety Act was to be assessed in terms of radiation protection. Study subjects are from 2014 to 2016, among university students in Seong-nam Korea and comparisons for analyses were made taking into account variables that are differences in annual, practical types, on-class and clinical practice students exposure dose. The analysis showed that exposures between on-class and clinical practice received were less than the annual dose limit of 1 mSv for the public. Then, some alternatives that excluding from frequent workers during on-class practice or mitigating the frequent workers' safety regulation for only on-class frequent workers can be considered. Optimization is how rational is the reduction in exposure dose to the costs required. Therefore, the results are hardly considered for optimization. If the data accumulated, it could be considered that the revision of the act could be evaluated and improved.

Protection against Whole Body γ-Irradiation Induced Oxidative Stress and Clastogenic Damage in Mice by Ginger Essential Oil

  • Jeena, Kottarapat;Liju, Vijayasteltar B;Ramanath, Viswanathan;Kuttan, Ramadasan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1325-1332
    • /
    • 2016
  • Radioprotective effects of ginger essential oil (GEO) on mortality, body weight alteration, hematological parameters, antioxidant status and chromosomal damage were studied in irradiated mice. Regression analysis of survival data in mice exposed to radiation yielded LD50/30 as 7.12 and 10.14 Gy for control (irradiation alone) and experimental (GEO-treated irradiated) mice, respectively, with a dose reduction factor (DRF) of 1.42. In mice exposed to whole-body gamma-irradiation (6 Gy), GEO pre-treatment at 100 and 500 mg/kg b.wt (orally) significantly ameliorated decreased hematological and immunological parameters. Radiation induced reduction in intestinal tissue antioxidant enzyme levels such as superoxide dismutase, catalase, glutathione peroxidase and glutathione was also reversed following administration of GEO. Tissue architecture of small intestine which was damaged following irradiation was improved upon administration of GEO. Anticlastogenic effects of GEO were studied by micronuclei assay, chromosomal aberration and alkaline gel electrophoresis assay. GEO significantly decreased the formation of micronuclei, increased the P/N ratio, inhibited the formation of chromosomal aberrations and protected agaisnt cellular DNA damage in bone marrow cells as revealed by comet assay. These results are supportive of use of GEO as a potential radioprotective compound.

Fertility Study of KTC-1, a New Semisynthetic Rifamycin Derivative, in Rats. (새로운 반합성 Rifamucin 유도체 KTC-1의 랫트 수태능력 시험)

  • 김종춘;정문구;노정구
    • Toxicological Research
    • /
    • v.12 no.1
    • /
    • pp.93-99
    • /
    • 1996
  • The effect of KTC-1, a new semisynthetic rifamycin antituberculous drug, on general toxicity, reproductive capability and fetal development was investigated in Sprague-Dawley rats. Male rats were administered KTC-1 with mashed feed from 63 days before mating to the end of mating period, and female rats were given from 14 days before mating to day 7 of gestation at dose levels of 0, 375, 750, and 1,500 ppm. The females were sacrificed on day 21 of gestation for examination of their fetuses. At 1,500 ppm, a reduction in body weight gain and testis atrophy were observed in male rats. Histological examination revealed testicular atrophy, absence or decrease of germinal cells, and vacuolization of Sertoli cells in testis. A reduction in body weight gain, a decrease in food consumption were found in female rats. In addition, decreases in the number of corpora lutea, iraplantations, and the litter size of live fetuses were seen. Mating, fertility, and pregnancy performances were also affected. There were no external abnormalities observed by examination of fetuses. At 750 ppm, a reduction in the body weight gain of male and female rats and decreases in the number of implantations and litter size were found. At 375 ppm, no treatment-related effects were observed. The results suggest that the no-effect dose levels (NOELs) of KTC-1 are 375 ppm for males and females on general toxicity, 750 ppm for males and females on reproductive capability, and 375 ppm for fetuses on embryonic development.

  • PDF

Dose Reduction and Image Quality Assessment of the CareDose 4D Technique on Abdomen Liver Computed Tomography (복부 간 CT 검사에서 CareDose 4D 사용에 따른 선량 감소 및 화질 평가)

  • Seok, Jong-Min;Jeon, Woo-Jin;Park, Young-Joon;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • The purpose of this study was to evaluate the clinical efficacy of 128 MDCT (multi-detector computed tomography) for reducing the CareDose 4D dose and comparing the image quality with the fixed tube current technique. For this purpose, we conducted the phantom and clinical studies to evaluate the exposure dose and image of the subject before and after applying the CareDose 4D system in abdominal examination using 128 MDCT. In the phantom study, ROI (Region of interest) was located at the center, 3, 6, 9, 12 o'clock, into two groups: group A without CareDose 4D and Group B applied were measured. In the clinical study, ROI was located at the liver 8 segments, divided into two groups too. The measured items were CT number, noise, and dose length product (DLP) dose. The result of CTDIvol (CT Dose Index volume) measurements in phantom and clinical studies were lower than those before CareDose 4D application, and dose and effective dose were also measured lower (p<.05). There was no difference in CT number before and after application (p>.05). In conclusion, using CareDose 4D, we can obtain optimal image information without deteriorating image quality while reducing patient dose.