• 제목/요약/키워드: Dose Reduction

검색결과 1,460건 처리시간 0.03초

Skin entrance dose for digital and film radiography in Korean dental schools

  • Cho Eun-Sang;Choi Kun-Ho;Kim Min-Gyu;Lim Hoi-Jeong;Yoon Suk-Ja;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.203-205
    • /
    • 2005
  • Purpose: This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Materials and Methods: Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician (s) at each school to set the exposure parameters and aiming the x-ray tube for the periapical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter : Unfors instruments, Billdal, Sweden). Results: The median dose was $491.2{\mu}Gy$ for digital radiography and $1,205.0{\mu}Gy$ for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Conclusion: Fifty-nine percent skin entrance dose reduction with digital periapical radiography was achieved over the film radiography in Korean dental schools.

  • PDF

하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구 (Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection)

  • 안형택;김재열;여운식;박용성;이귀원;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구 (A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom)

  • 김영옥;성열훈
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1714-1720
    • /
    • 2012
  • 다중 검출기 컴퓨터단층촬영(multi-detector computed tomography; MDCT) 장비에서 이용되는 다양한 자동노출제어(automatic exposure control; AEC) 시스템에 대한 선량 감소 정도와 영상의 품질을 비교 평가하였다. 연구에 이용한 AEC 시스템은 General Electric(GE)사의 Auto-mA 3D, Philips사의 DoseRight, 그리고 Siemens사의 Care Dose 4D를 이용하였다. 모든 실험에서 X-선 노출 조건을 가능한 한 동일하게 하였다. 다양한 AEC 시스템에서 선량 감소 평가는 인체 모형을 이용하여 고정관류기법과 비교하여 평가하였다. 또한 영상 품질은 CT 계수(number)의 표준 편차를 이용하여 영상의 잡음을 측정하였다. 그 결과 AEC 시스템을 적용할 때 Auto-mA 3D는 35.3%, DoseRight는 58.2%, Care Dose 4D는 48.6%의 최대 선량감소가 있었으며, 영상품질에서는 Care Dose 4D의 강함/약함 (Strong/Weak)의 조합에서 유의한 차이가 없었다(P=0.269). 이런 다양한 AEC 시스템의 적용은 고품질의 영상을 유지하면서 선량을 감소하는데 매우 유용 할 것이라고 사료된다.

심장혈관검사에서 전산화단층검사와 혈관조영검사의 입사표면선량 및 조영제 사용량에 관한 분석 (Analysis on the Entrance Surface Dose and Contrast Medium Dose at Computed Tomography and Angiography in Cardiovascular Examination)

  • 서영현;한재복;최남길;송종남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.535-541
    • /
    • 2016
  • 심장혈관검사에서 전산화단층검사(cardiac computed tomography; CCTA)와 혈관조영검사(coronary angiography; CAG)의 입사표면선량을 후향적 방법으로 분석하여 선량의 저감화 방안을 알아보고 조영제 사용량을 실제 측정하여 신기능 저하 환자 및 부작용 발생 확률이 높은 환자 등의 검사 선택 결정에 대한 역할을 확인하고자 하였다. 양 검사의 입사표면선량인 전산화단층촬영지수($CTDI_{vol}$)값과 공기 커마(air kerma)값, 그리고 프레임 수에 따른 조영제 사용량 등을 비교 분석하였다. 실험 대상으로는 2014년 5월부터 2016년 5월까지 본원에서 CCTA와 CAG를 시행한 21명(남11, 여10)을 대상으로 하였고 연령대는 48~85세(평균 $65{\pm}10$세)이고, 몸무게는 37.6~83.3 kg(평균 $63{\pm}6kg$)였다. CAG보다 CCTA를 이용한 심장혈관 검사가 선량의 감소를 기대할 수 있고 조영제 사용량에 있어서는 CCTA보다 CAG가 더 적은 양을 사용한다는 것을 알 수 있었다. 특히 CAG에서 프레임 수가 증가함에 따라 조영제 사용량이 늘어나므로 촬영범위에 적합한 프레임 수를 선택하여 검사 할수록 조영제 사용량을 더욱 감소시킬 수 있을 것으로 사료된다.

X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구 (A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter)

  • 김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

방사선(放射線)에 의(依)한 밤나무의 돌연변이(突然變異) 육종(育種)에 관(關)한 연구(硏究) (Studies on the Mutation Breeding in Castanea SP.)

  • 김지문
    • 한국산림과학회지
    • /
    • 제25권1호
    • /
    • pp.80-84
    • /
    • 1975
  • 밤나무와 약밤나무의 종자(種子), 접수(接穗) 및 생체(生體)에 감마선(線)을 총선량별(總線量別), 총량률별(總量率別)로 조사(照射)하여 방사선(放射線)의 생물학적(生物學的) 효과(効果) 및 돌연변이(突然變異)의 유기(誘起)를 조사(調査)한 결과(結果)를 다음과 같이 요약(要約)한다. 1. 밤나무의 ${\gamma}$선조사(線照射)에 의(依)한 종자발아율(種子發芽率) 반감선량(半減線量)은 4.6 kR 인데 접목활착율(接木活着率) 반감선량(半減線量)은 3.1 kR으로 더욱 높은 감수성(感受性)을 보였다. 2. 종자조사(種子照射) 5 kR구(區)에서 낮은 빈도(頻度)(0.84%로 albino 개체(個體)가 나타났으며 선량(線量)의 증가(增加)에 따라 묘장(苗長)이 유의성(有意性)있게 감소(減少)하였다. 3. 접수조사(接穗照射)에 의(依)한 접목활착율(接木活着率) 반감선량(半減線量)은 급조사(急照射)에서 약밤나무 및 밤나무가 3.2 kR 및 3.1 kR인데 반급조사(半急照射)에서는 10.2 kR으로서 3배(倍)의 높은 누적선량(累積線量)의 조사(照射)가 가능(可能)하였다. 4. 약밤나무의 휴면기(休眠期) 생체(生體) 완조사(緩照射)의 총선량(總線量) 7.5-4.9 kR, 선량율(線量率) 10-98 R/day구(區)에서 대형엽아조변이(大形葉芽條變異)가 높은 빈도(頻度)(16.6%)로 나타났으며 평균엽면적(平均葉面積) $96.36cm^2$로서 정상엽(正常葉) $26.28cm^2$보다 매우 컸다.

  • PDF

비스무스 차폐체 개발을 통한 소아 방사선검사의 피폭에 관한 연구 (Pediatric Radiation Examination by Development of Bismuth Shield Research on Radiation Exposure)

  • 김훈;김용근;김준년;위승현;박은경;채명준;백부길;김은혜;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.205-211
    • /
    • 2024
  • Currently, with the development of technologies, X-ray examinations for medical examinations at hospital is increasing. This study was conducted to help reduce radiation exposure by measuring the exposure dose received by pediatric patients and the spatial dose of the X-ray room. Dosimeters were installed in the eyeball, thyroid gland, breast, gonads and 4 directions at a distance of 30 cm, 40 cm, 50 cm from the phantom. The dose was measured ten times each, before, and after the application of the bismuth shield under the examination conditions of the head, chest, and abdomen of pediatric patients. Under the condition of head examination, when a shielding was applied, the dose reduction rate was 68.58% for the eyeball, 72.88% for the thyroid, 84.2% for the breast, and 72.36% for the gonad. The chest examination showed reductions of 19.56% eyeball, 56.98% thyroid, 1.21% breast, and 0.68% gonad. The abdominal examination showed reduction rates of 2.6% eyeball, 10.67% thyroid, 19.85% breast, and 82.02% gonad. Spatial dose decreased by 62.25% at 30 cm, 61.16% at 40 cm, and 68.68% at 50 cm. When the bismuth shield was applied, there was a decrease in dose across all examinations, as well as a reduction in spatial dose. Continued research on the use of bismuth shields will help radiological technologists achieve their goal of dose reduction.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • 제7권4호
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

심혈관조영술 및 중재술 시 환자 선량 감소방안 (Patient Exposure Dose Reduction in Coronary Angiography & Intervention)

  • 임도형;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.69-76
    • /
    • 2022
  • This study, the method of reducing the exposure dose by changing the geometrical requirements among the preceding studies and the method of directly wearing a protector on the patient were used to expose the patient. A comparative experiment was conducted on the method of reducing the dose and the most effective method for reducing the exposure dose was investigated. Using the phantom, the dose of the lens, thyroid gland, and gonad gland in the 5 views most used in coronary angiography and intervention accumulated 5 times for 10 seconds at 60~70 kV, 200~250 mA as an automatic controller of the angiography system, and measured by Optically Stimulated Luminescent Dosimeter(OSLD). SID 100 cm and Cine 15 f/s as a control group the experiment was conducted by dividing the experimental group into 3 groups: a group lowered to Cine 7.5 f/s, a phantom protector, and a group lowered to 95 cm SID. As a result of the experiment, showing decrease in exposure dose compared to the control group. Lowering the cine frame may be the simplest and most effective method to reduce the exposure dose, but there is a limit that it cannot be applied if the operator judges that the diagnostic value is small or feels uncomfortable with the procedure. Conclusion as fallow reducing the exposure dose by directly wearing protector is the next best solution, and it is hoped that the conclusions obtained through this study will help reduce the exposure dose to unnecessary organ.