• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.052 seconds

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

Effect of Low-dose Aspirin on Implantation and Pregnancy Rates in Patients Undergoing Frozen-thawed Embryo Transfer (동결보존 배아 이식에서 저 용량 아스피린 투여가 임신율과 착상율에 미치는 영향에 관한 연구)

  • Kim, Min Ji;Lee, Hyun Jung;Yu, Young;Seo, Back Kyung;Cha, Sun Hwa;Kim, Hae Suk;Song, In Ok;Byun, Hye Kyung;Koong, Mi Kyoung;Kang, Inn Soo;Yang, Kwang Moon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.32 no.3
    • /
    • pp.243-251
    • /
    • 2005
  • Objective: Low-dose aspirin have been proposed to improving endometrial receptivity and pregnancy rate in COH-IVF by increasing endometrial perfusion. However, the effect of low-dose aspirin in COH-IVF could be negligible because there have been large quantity of other important factors responsible for changing endometrial perfusion accompanied by COH procedure. In contrast, in frozen-thawed embryo transfer cycles which were not accompanied by COH procedure, the effects of low-dose aspirin in endometrial blood flow seems to be more certain than in COH-IVF cycles. In this study, we analyzed the effect of low-dose aspirin treatment on implantation and pregnancy rates in patients undergoing frozen-thawed embryo transfer Methods: From January 2003 to December 2003, total 264 cycles from 264 patients who attended infertility clinic at Samsung Cheil Hospital were enrolled in this study. All cases included in this study, embryos were frozen and thawed at the pronuclear stage and three days after incubation, at least 2 or more good quality embryos were transferred into uterus. In study group, low dose aspirin (100 mg/day) was administrated from the first or second date of menstrual day to 9 days after embryo transfer. On the other hand, control group did not take any medicine except estradiol valerate for endometrial priming. Several variables including implantation and pregnancy rates were compared in both groups. After then, each groups were stratified by endometrial thickness checked at embryo transfer (ET) day such as (28 mm versus <8 mm) and same variables above described were compared between study and control groups. Results: The mean age, infertility duration, endometrial thickness at embryo transfer day and mean number of transferred embryo were not significantly different in both groups. Also, implantation rates (study group: 15.8%, control group: 20.5%) and pregnancy rate (study group: 45.1%, control group: 43.5%) were not significantly different between two groups. (p>0.05) After we analyzed same variables stratified by endometrial thickness checked at embryo transfer day, we could not found any significant difference between study and control groups. Conclusions: Low-dose aspirin treatment seems to have no advantage of improving implantation and pregnancy rates in patients undergoing frozen-thawed embryo transfer.

Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy (국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료)

  • Choi Chul-Won;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Yoo Hyung-Jun;Lee Dong-Han;Ji Young-Hoon;Han Chul-Ju;Kim Jin;Kim Young-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.11-20
    • /
    • 2006
  • Puroose: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. Materials and Methods: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status ${\leq}3$ and locally advanced pancreas cancer without distant metastasis, evaluated by CT or PET/CT, were included. We administered stereotactic RT consisting of either 33 Gy, 36 Gy or 39 Gy in 3 fractions to 6, 4 and 9 patients, respectively, in an effort to increase the radiation dose step by step, and analyzed the survival rate and gastrointestinal toxicities by the acute radiation morbidity criteria of Radiation Therapeutic Oncology Group (RTOG). Prognostic factors of age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9, planning target volume (PTV), and adjacent organ and vessel invasion on CT scan were evaluated by Log Rank test. Results: The median survival time was 11 months with 1-year survival rate of 36.8%. During follow-up period (range $3{\sim}20$ months, median 10 months), no significant gastrointestinal acute toxicity (RTOG grade 3) was observed. In univariate analysis, age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9 level, and adjacent organ and vessel invasion did not show any significant changes of survival rate, however, patients with PTV (80 cc showed more favorable survival rate than those with PTV>80 cc (p-value<0.05). In multivariate analysis, age younger than 65 years and PTV>80 cc showed better survival rate. Conclusion: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.

Radiotherapy Results of Uterine Cervix Cancer Stape IIB : Overall Survival, Prognostic factors, Patterns of Failure and Late Complications (자궁경부암 병기 IIB에서의 방사선 치료 성적: 생존율 및 예후인자, 치료 후 실패양상, 만성 합병증)

  • Kim Eun-Seog;Choi Doo-Ho;Huh Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.51-61
    • /
    • 1998
  • Purpose : Treatment of choice for uterine cervix cancer stage IIB is radiotherapy. We analyzed survivals, Prognostic factors, patterns of failure and complications. Materials and Methods : This is a retrospective analysis of 167 patients with stage IIB carcinoma of uterine cervix treated with curative external pelvic and high dose rate intracavitary radiotherapy at the Department of Therapeutic Radiology, Soonchunhyang University Hospital from August 1985 to August 1994. All the patients followed up from 3 to 141 months(mean 60 months) and age of patients ranged from 31 to 78 years at presentation(mean : 55 years). Results : Overall complete response rate was $84\%$. The response rate for squamous cell carcimoma and adenocarcinoma were $86\%$ and $60\%$, respectively. Overall 5-years survival rate and disease free survival rate was 62 and $59\%$, respectively Mass size and treatment response were significant Prognostic factors for survival Pathologic type and parametrial involvement were marginally significants Prognostic factors. Local failure was 43 cases, distant metastasis was 14 cases and local failure plus distant metastasis was 3 cases, and most of local failures occurred within 24 months, distant metastasis within 12 months after treatment Twenty eight($16.8\%$) patients developed late rectal and urinary complications There were tendency to increasing severity and frequency according to increased fractional dose and total(rectal and bladder) dose. Conclusions : Survival rate was significantly related to tumor size and radiotherapy response. Tumor size should be considered in the clinical s1aging. To increased survival and local control, clinical trials such as decreasing duration of radiotherapy or addition of chemotherapy is needed. To detect early recurrence, regular follow up after RT is important. Because total rectal and bladder dose affected late complications. meticulous vaginal packing is needed to optimize dose of normal tissues and to decrease late complications.

  • PDF

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.