• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.029 seconds

The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials (방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定))

  • Huh, Joon;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

Electrical Characteristics of IGBT for Gate Bias under ${\gamma}$ Irradiation (게이트바이어스에서 감마방사선의 IGBT 전기적특성)

  • Lho, Young-Hwan;Lee, Sang-Yong;Kim, Jong-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.165-168
    • /
    • 2008
  • The experimental results of exposing IGBT (Insulated Gate Bipolar Transistor) samples to gamma radiation source show shifting of threshold voltages in the MOSFET and degradation of carrier mobility and current gains. At low total dose rate, the shift of threshold voltage is the major contribution of current increases, but for more than some total dose, the current is increased because of the current gain degradation occurred in the vertical PNP at the output of the IGBTs. In the paper, the collector current characteristics as a function of gate emitter voltage (VGE) curves are tested and analyzed with the model considering the radiation damage on the devices for gate bias and different dose. In addition, the model parameters between simulations and experiments are found and studied.

  • PDF

Nutritional strategy of early amino acid administration in very low birth weight infants

  • Lee, Byong Sop
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.3
    • /
    • pp.77-83
    • /
    • 2015
  • Relative to a fetus of the same gestational age, very low birth weight (VLBW) infants are more likely to be underfed and to undergo growth restriction during their early hospital stay. The current trend towards "early and aggressive" nutritional strategies in VLBW infants aims to overcome the early nutritional deficiency and thereby boost postnatal catch-up growth, simultaneously improving long-term neurodevelopmental outcomes. Although the minimum starting amino acid (AA) dose to prevent negative nitrogen balance is well established, the upper limit and the rate of increase of early AA doses are controversial. Most randomized controlled trials show that early and high-dose (target, 3.5 to 4.9 g/kg/day) AA regimens, with or without high nonprotein calories, do not improve long-term growth and neurodevelopment. High-dose AA supplementation may lead to early metabolic disturbances and excessive or disproportionate plasma AA levels, particularly in infants of very low gestational age. Further large studies are needed to clarify the optimal strategy for early administration of parenteral AA doses in VLBW infants.

Development and Application of the Semiconductor Neutron Radiation Detector (반도체 중성자 탐지소자 개발 및 응용)

  • Lee, Nam-Ho;Lee, Hong-Kyu;Youk, Young-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.299-304
    • /
    • 2011
  • In this paper, we developed the semiconductor neutron radiation detector and the multi-purpose radiation detection technologies for the next generation military personal surveymeter. The PIN type semiconductor neutron detector and the prototype measure the neutron radiation dose upto 1,000cGy with ${\pm}20%$ error. It also have a good performance about the Gamma, Alpha and Beta radiation and MIL-STD-810F.

Important Radionuclides and Their Sensitivity for Ground water Pathway of a Hypothetical Near-Surface Disposal Facility

  • Park, J. W.;K. Chang;Kim, C. L.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.156-165
    • /
    • 2001
  • A radiological safety assessment was performed for a hypothetical near-surface radioactive waste repository as a simple screening calculation to identify important nuclides and to provide insights on the data needs for a successful demonstration of compliance. Individual effective doses were calculated for a conservative ground water pathway scenario considering well drilling near the site boundary. Sensitivity of resulting ingestion dose to input parameter values was also analyzed using Monte Carlo sampling. Considering peak dose rate and assessment time scale, C-14 and T-129 were identified as important nuclides and U-235 and U-238 as potentially important nuclides. For C-14, the dose was most sensitive to Darcy velocity in aquifer The distribution coefficient showed high degree of sensitivity for I-129 release.

  • PDF

APPLICATION OF ALANINE/ESR SPECTRUM SHAPE CHANGE IN GAMMA DOSIMETRY

  • Choi, Hoon;Kim, Jeong-In;Lee, Byung-Ill;Lim, Young-Ki
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.313-318
    • /
    • 2010
  • Alnine pellets were installed in a nuclear power plant for one or two operation cycles and measured by electron spin resonance (ESR) spectrometers for dosimetry. Dose and "x/y ratio", i.e., satellite peak over main center peak ratio, were measured for the returned alanine dosimeters from the nuclear power plant and compared to the values of reference alanine dosimeters exposed only to gamma rays. The variation of the x/y ratio change depended on the population of radicals from each radiation component with different LET. The gamma dose in a mixed radiation field was estimated by an additive gamma ray irradiation experiment and the measured dose rate at specified locations in the containment building.

Saccharomyces cerevisiae의 물질대사에 미치는 중성자의 영향

  • 이민재
    • Journal of Plant Biology
    • /
    • v.7 no.4
    • /
    • pp.9-14
    • /
    • 1964
  • According to the results measured the respiratory quotient of Saccharomyces cerevisiae with neutron radiation by manometric direct method, the respiratory quotient of them was stimulated at the dose(7$\times$106N/$\textrm{cm}^2$/sec) of neutron radiation for 60 seconds, and was inhibited in each group irradiated at the high dose (7$\times$108N/$\textrm{cm}^2$/sec) of neutron. Its physiological effects influenced on neutron had relations with respiratory quotient, reproductive rate and fermentation in the curve of normal logarithmic phase. The multiple reactions which appeared in yeast, indicated that a great deal of physiological function were closely correlated with the irradiated dosage of neutron. The kinds of free amino acid in yeast irradiated with neutron were different from those of unirradiated yeast. The activityof dehydrogenase system accelerated the metabolic function of yeast irradiated at some low dose of neutron. By this results, it may demonstrate that the fact which the phenomena obtained in the stimulation of neutron possess its character for several generation, is dependent on the theory of mutation. Subsequently, it seemed reasonable certain dominant type of microorganisms.

  • PDF

Interaction of Antitubercular Drug (II) - Drug Interaction of Rifampicin and Isoniazid (항결핵약물의 상호작용 (II) - 리팜피신과 이소니아짓의 약물상호작용)

  • 범진필;최준식;이진환
    • YAKHAK HOEJI
    • /
    • v.31 no.4
    • /
    • pp.204-212
    • /
    • 1987
  • Rifampicin is an indispensable drug along with isoniazid for the control of tuberculosis and is usually prescribed as the combination of rifampicin and isoniazid. This paper is attemtped to investigate the interaction of rifampicin and isoniazid. Isoniazid was administered orally at a dose of 30mg/kg of rabbits pretreated with rifampicin 7.5mg/kg, 15mg/kg, and 30mg/kg, respectively twice daily for 9 days. The results are as follows: The blood level and relative bioavailability of isoniazid were decreased significantly (p<0.05) by rifampicin at a dose of 15mg/kg and 30mg/kg. The renal clearance of total isoniazid and ratio of its metabolites to isoniazid were increased significantly (p<0.05) by rifampicin at a dose of 15mg/kg and 30mg/kg. It seemed to be due to enzyme induction by rifampicin. Elimination rate constant ($\beta$) of isoniazid was increased and half life ($t_{1/2$\beta}$) was decreased by rifampicin pretreatment. Dosage regimen of isoniazid after long term administration of rifampicin should be adjusted carefully.

  • PDF

Radiation-Induced Graft Copolymerization of Acrylic Acid onto Polyester

  • Chang, Hoon-Sean;Kong, Young-Kun;Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.65-74
    • /
    • 1977
  • The radiation-induced graft polymerization of acrylic acid onto polyester fabric was investigated with accelerated electron beams as ratiation source at high dose rates. Homopolymerization was suppressed by addition of cations which is known as homopolymerization inhibitor, but this practical advantage was obtained at the expense of grafting efficiency. The rate of grafting (%/sec) was proportional to the 0.82th power of dose rates over the range from 1.6$\times$10$^{6}$ to 10$\times$10$^{6}$ rad/sec. The grafted polyester fabric showed considerable improvement in moisture regain and antistatic properties.

  • PDF

Antihypertensive Action of Clonidine Patch (Clonidine Patch제의 효능시험 : 혈압강하작용)

  • 정재훈;신찬영;류재련;박우일;고광호
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.205-207
    • /
    • 1996
  • Clonidine, an antihypertensive drug, stimulates postsynaptic alpha-2 adrenergic receptors in the central nervous system and lowers arterial pressure through the effects on both cardiac output and peripheral resistance. However, many patients experience that sedation and xerostomia occur upon oral administration of clonidine. These side effects are due to high plasma peak concentration and can be avoided when clonidine is given transdermally. In this study, we tested the antihypertensive effects of trandermal administration of clonidine patch on spontaneously hypertensive rat (SHR) which is a model animal for human essential hypertension. Forty eight SHR (male) were divided into six groups according to the dose levels, respectively. After transdermal administration of clonidine patch of each dose, systolic blood pressure and heart rate were measured. Clonidine patch produced maximal antihypertensive and bradycardiac effects 48 hrs after administration and antihypertensive effects showed dose-dependency. We suggest that antihypertensive effects of clonidine patch are similar to those of orally given clonidine and clonidine patch can be used instead of clonidine tablet.

  • PDF