• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.03 seconds

Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF

DIFFERENTIAL EXPRESSION OF RADIATION RESPONSE GENES IN SPLEEN, LUNG, AND LIVER OF RATS FOLLOWING ACUTE OR CHRONIC RADIATION EXPOSURE

  • Jin, Hee;Jin, Yeung Bae;Lee, Ju-Woon;Kim, Jae-Kyung;Lee, Yun-Sil
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.25-35
    • /
    • 2015
  • We analyzed the differential effects of histopathology, apoptosis and expression of radiation response genes after chronic low dose rate (LDR) and acute high dose rate (HDR) radiation exposure in spleen, lung and liver of rats. Female 6-week-old Sprague-Dawley rats were used. For chronic low-dose whole body irradiation, rats were maintained for 14 days in a $^{60}Co$ gamma ray irradiated room and received a cumulative dose of 2 Gy or 5 Gy. Rats in the acute whole body exposure group were exposed to an equal dose of radiation delivered as a single pulse ($^{137}Cs$-gamma). At 24 hours after exposure, spleen, lung and liver tissues were extracted for histopathologic examination, western blotting and RT-PCR analysis. 1. The spleen showed the most dramatic differential response to acute and chronic exposure, with the induction of substantial tissue damage by HDR but not by LDR radiation. Effects of LDR radiation on the lung were only apparent at the higher dose (5 Gy), but not at lower dose (2 Gy). In the liver, HDR and LDR exposure induced a similar damage response at both doses. RT-PCR analysis identified cyclin G1 as a LDR-responsive gene in the spleen of rats exposed to 2 Gy and 5 Gy gamma radiation and in the lung of animals irradiated with 5 Gy. 2. The effects of LDR radiation differed among lung, liver, and spleen tissues. The spleen showed the greatest differential effect between HDR and LDR. The response to LDR radiation may involve expression of cyclin G1.

Quantitative Evaluation of Radiation Dose Rates for Depleted Uranium in PRIDE Facility

  • Cho, Il Je;Sim, Jee Hyung;Kim, Yong Soo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.378-383
    • /
    • 2016
  • Background: Radiation dose rates in PRIDE facility is evaluated quantitatively for assessing radiation safety of workers because of large amounts of depleted uranium being handled in PRIDE facility. Even if direct radiation from depleted uranium is very low and will not expose a worker to significant amounts of external radiation. Materials and Methods: ORIGEN-ARP code was used for calculating the neutron and gamma source term being generated from depleted uranium (DU), and the MCNP5 code was used for calculating the neutron and gamma fluxes and dose rates. Results and Discussion: The neutron and gamma fluxes and dose rates due to DU on spherical surface of 30 cm radius were calculated with the variation of DU mass and density. In this calculation, an imaginary case in which DU density is zero was added to check the self-shielding effect of DU. In this case, the DU sphere was modeled as a point. In case of DU mixed with molten salt of 50-250 g, the neutron and gamma fluxes were calculated respectively. It was found that the molten salt contents in DU had little effect on the neutron and the gamma fluxes. The neutron and the gamma fluxes, under the respective conditions of 1 and 5 kg mass of DU, and 5 and $19.1g{\cdot}cm^{-3}$ density of DU, were calculated with the molten salt (LiCl+KCl) of 50 g fixed, and compared with the source term. As the results, similar tendency was found in neutron and gamma fluxes with the variation of DU mass and density when compared with source spectra, except their magnitudes. Conclusion: In the case of the DU mass over 5 kg, the dose rate was shown to be higher than the environmental dose rate. From these results, it is concluded that if a worker would do an experiment with DU having over 5 kg of mass, the worker should be careful in order not to be exposed to the radiation.

Does Low-Dose Heparin Have a Significant Role in Free Flap Surgery?

  • An, Mun-Young;Shin, Jin Yong;Lee, Young-Keun;Sabbagh, M. Diya;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.3
    • /
    • pp.162-165
    • /
    • 2017
  • Background: It is controversial issue that heparin decreases thrombosis for microsurgical anastomosis, and its effective role is under discussion. This study is for proving whether low-dose heparin is preventing thrombosis in free flap reconstruction. Methods: Through chart reviews of 134 patients, using low-dose heparin for free tissue transfer from 2011 to 2016, retrospective analysis was performed. 33 patients received low-dose heparin therapy after surgery. And 101 patients received no-heparin therapy. Complications included flap necrosis, hematoma formation, dehiscence and infection. Results: In no-heparin therapy group, comparing the flap necrosis revealed 16 cases (15.84%). And, flap necrosis was 6 cases (18.18%) in low-dose heparin therapy group. The statistical analysis of flap necrosis rate showed no significant difference (p=0.75). The results showed that there was no significant difference of flap necrosis rate between two groups. Conclusion: In this study, patients in the low-dose heparin group had no significantly lower rates of flap failure compared with no-heparin group. This suggests that low-dose heparin may not prevent thrombosis and subsequent flap failure to a significant extent.

Germination and Seedling Growth in Response to Ionizing Radiation in Creeping Bentgrass (Agrostis palustris Huds.)

  • Lee, Yong Jin;Hong, Min Jeong;Kim, Dae Yeon;Lee, Tong Geon;Kim, Dong Sub;Kim, Jin Baek;Lee, Byung Cheol;Han, Young Hwan;Seo, Yong Weon
    • Korean Journal of Breeding Science
    • /
    • v.40 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • It was previously pointed out that mutation is the ultimate source of variation. Adequate variation is needed for plant breeding if there is a limitation in natural genetic resources. When the ionizing radiation has been known to cause chromosomal and genomic alternations, it is widely used for inducing mutagenesis. The electron beam as an ionizing radiation is the principal physical mutagens that induces mutation and effectively used in plant breeding. Since dose-response relationships of electron beam in plant species are rarely known, we investigated the seed germination rate and early seedling growth of irradiated seeds of creeping bentgrass (Agrostis palustris Huds., cv Penn-A1) with various electron beam irradiating conditions (1, 1.3, 2 MeV at both 0.03 mA and 0.06 mA with dose of 100 Gy (Gray) and 0.03, 1, 1.3, 2 MeV at 0.03 mA with dose of 200 Gy, respectively) using electron accelerator at Korea Atomic Energy Research Institute. The growth parameters in terms of shoot length, primary root length, and secondary root length showed similar response between 0.06 / 1 (mA / MeV) at 100 Gy and 0.03 / 0.3 (mA / MeV) at 200 Gy. Bentgrass seed germination was mainly affected by the intensity of irradiated dose (Gray). Germination rate was lowered as the irradiated dose increased. On the other hand, early seedling growth was mainly governed not by the dose of radiation but by voltage.

Variation of optimization techniques for high dose rate brachytherapy in cervical cancer treatment

  • Azahari, Ahmad Naqiuddin;Ghani, Ahmad Tirmizi;Abdullah, Reduan;Jayamani, Jayapramila;Appalanaido, Gokula Kumar;Jalil, Jasmin;Aziz, Mohd Zahri Abdul
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1414-1420
    • /
    • 2022
  • High dose rate (HDR) brachytherapy treatment planning usually involves optimization methods to deliver uniform dose to the target volume and minimize dose to the healthy tissues. Four optimizations were used to evaluate the high-risk clinical target volume (HRCTV) coverage and organ at risk (OAR). Dose-volume histogram (DVH) and dosimetric parameters were analyzed and evaluated. Better coverage was achieved with PGO (mean CI = 0.95), but there were no significant mean CI differences than GrO (p = 0.03322). Mean EQD2 doses to HRCTV (D90) were also superior for PGO with no significant mean EQD2 doses than GrO (p = 0.9410). The mean EQD2 doses to bladder, rectum, and sigmoid were significantly higher for NO plan than PO, GrO, and PGO. PO significantly reduced the mean EQD2 doses to bladder, rectum, and sigmoid but compromising the conformity index to HRCTV. PGO was superior in conformity index (CI) and mean EQD2 doses to HRCTV compared with the GrO plan but not statistically significant. The mean EQD2 doses to the rectum by PGO plan slightly exceeded the limit from ABS recommendation (mean EQD2 dose = 78.08 Gy EQD2). However, PGO can shorten the treatment planning process without compromising the CI and keeping the OARs dose below the tolerance limit.

Dose Intensity of Oxaliplatin in 5-Fluorouracil and Leucovorin Regimens in Pretreated Metastatic Colorectal Cancer (5-Fluorouracil, Leucovorin과 병용 투여된 Oxaliplatin의 Dose Intensity가 재발된 전이성 대장암 치료에 미치는 영향)

  • Jeong, Kyong-Ju;Choi, Seung-Ki;Oh, Jung-Mi
    • Korean Journal of Clinical Pharmacy
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Studies of oxaliplatin, 5-fluorouracil and leucovorin in pretreated metastatic colorectal cancer showed that oxaliplatin dose intensity is important prognostic factor for objective response rates and progression-free-survival (PFS). To evaluate response rates, PFS and toxicity according to oxaliplatin dose intensity, we retrospectively analyzed data from patients with metastatic colorectal cancer received oxaliplatin,5-fluorouracil, leucovorin regimens. Sixty-three patients were reviewed in this study, 42 patients received low dose intensity oxaliplatin (LDI: $\leq85\;mg/m^2/2wks$) and 21 patients high dose intensity oxaliplatin (HDI: $>85\;mg/m^2/2wks$). Objective responses occurred in 10 $(47.7\%)$ HDI patients and 9 $(21.4\%)$ LDI patients (p = 0.014). Median PFS was 24.7 weeks in HDI group, with $45.1\%$ of HDI patients progression free at 6 months, and 20.5 weeks in LDI group, with $33.5\%$ of LDI patients progression free at 6 months (p = 0.344). Increased oxaliplatin dose intensity was not associated with neutropenia, thrombocytopenia, neuropathy, nausea and vomiting. This study showed that oxaliplatin dose intensification significantly improves objective response rate in pretreated metastatic colorectal cancer without increasing severe toxicity.

  • PDF

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

High Dose Rate Cobalt-60 After Loading Intracavitary Therapy of the Uterine Cervical Carcinoma in Srinagarind Hospital, Analysis of Residual Disease

  • Pesee, Montien;Krusun, Srichai;Padoongcharoen, Prawat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4835-4837
    • /
    • 2012
  • Objectives: To evaluate residual disease in uterine cervical cancer patients treated with teletherapy using combined high dose rate Cobalt-60 brachytherapy. Materials and Methods: A retrospective study of uterine cervical cancer patients, FIGO stages IB-IVB (International Federation of Gynecologists and Obstetricians recommendations), treated by radiotherapy alone between April 1986 and December 1988 was conducted and the outcomes analysed. The patients were treated using teletherapy 50 Gy/25 fractions, five fractions per week to the whole pelvis together with HDR Cobalt -60 afterloading brachytherapy of 850 cGy/fraction, weekly to point A for 2 fractions. Results: The study covered 141 patients with uterine cervical cancer. The mean age was 50.0 years with a range of 30-78 years. The mean tumor size was 4.1 cm in diameter (range 1-8 cm). Mean follow - up time was 2.94 years (range 1 month-6.92 years). The overall incidence of residual locoregional disease was 3.5%. Residual disease, according to stage IIB, IIIB and IVA was present in 2.78%, 3.37% and 50.0%. It was noted that there was no evidence of residual disease in stage IB and IIA cases. Conclusion: Combined teletherapy along with high dose rate Cobalt -60 brachytherapy of 850 cGy/fraction, weekly to point A for 2 fractions resulted in overall 3.5% residual disease and a 96.5% complete response. The proposed recommendation for improving outcome is initiation of measurements for early detection of disease.

The Treatment of Uterine Cervical Cancer Using High Dose Rate Co-60 Sources (고선량율(高線量率) 강내조사법(腔內照射法)을 이용(利用)한 자궁경암(子宮頸癌) 방사선(放射線) 치료(治療))

  • Kim, G.E.;Suh, C.O.;Lee, D.H.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.95-102
    • /
    • 1983
  • The radical treatment of uterine cervical cancer by interacavitary radium or cesium, in combination with teletherapy are well known. Although the result of such treatment should not give rise to complacency, problem of radiation exposure to medical staff had not been resolved. Fortunately, many attempts have been made to reduce this hazard, most of which take the form of afterloading applicators with a suitably shielded radioisotope. In order to avoid hazardous radiation exposure to staffs concerned with brachytherapy, RALS using high intensity source of Co-60, have been employed at Yonsei Cancer Center since May, 1979. It allows rectal and bladder doses to be kept low, while maintaining a satifactory usual dose distribution of the other type of applicators, and the short treatment time allow four or five patients to be treated per hour. It also removes much patient's discomfort and the difficulties of nursing these patients. Since the first introduction in Korea, over seven hundred cases with various stage of uterine cervical cancer have been treated on a radical basis at this center last 4 years. These authors have strongly attracted attention to the results in terms of local control rate, survival s and morbidity compared with those of conventional low dose rate radiotherapy. Retrospective interim analysis of data was preliminarily accomplished through the labored follow-up study of 340 cases treated during initial 2 years and the radiobiologic standpoint of high dose rate intracavitary irradiation will be discussed.

  • PDF