• Title/Summary/Keyword: Dose Rate

Search Result 3,201, Processing Time 0.035 seconds

Short-term protein intake increases fractional synthesis rate of muscle protein in the elderly: meta-analysis

  • Gweon, Hyun-Soo;Sung, Hee-Ja;Lee, Dae-Hee
    • Nutrition Research and Practice
    • /
    • v.4 no.5
    • /
    • pp.375-382
    • /
    • 2010
  • The precise effects of protein intake on fractional synthesis rate (FSR) of muscle protein are still under debate. The sample size of these studies was small and the conclusions in young and elderly subjects were inconsistent. To assess the effect of dietary protein intake on the FSR level, we conducted a meta-analysis of controlled protein intake trials. Random-effects models were used to calculate the weighted mean differences (WMDs). Ten studies were included and effects of short-term protein intake were evaluated. In an overall pooled estimate, protein intake significantly increased the FSR (20 trials, 368 participants; WMD: 0.025%/h; 95%CI: 0.019-0.031; P < 0.0001). Meta-regression analysis suggested that the protein dose was positively related to the effect size (regression coefficient = 0.108%/h; 95%CI: 0.035, 0.182; P = 0.009). A subgroup analysis indicated that protein intake significantly increased FSR when the protein dose was ${\leq}$ 0.80 g/kg BW (16 trials, 308 participants; WMD: 0.027%/h; 95%CI: 0.019-0.031; P < 0.0001), but did not affect FSR when the protein dose was > 0.80 g/kg BW (4 trials, 60 participants; WMD: 0.016%/h; 95%CI: 0.004-0.029; P = 0.98). In conclusion, this study is the first integrated results showing that a short-term protein intake is effective at improving the FSR of muscle protein in the healthy elderly as well as young subjects. This beneficial effect seems to be dose-dependent when the dose levels of protein range from 0.08 to 0.80 g/kg BW.

Radiosurgery for Cerebral Arteriovenous Malformation (AVM) : Current Treatment Strategy and Radiosurgical Technique for Large Cerebral AVM

  • Byun, Joonho;Kwon, Do Hoon;Lee, Do Heui;Park, Wonhyoung;Park, Jung Cheol;Ahn, Jae Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.4
    • /
    • pp.415-426
    • /
    • 2020
  • Arteriovenous malformations (AVMs) are congenital anomalies of the cerebrovascular system. AVM harbors 2.2% annual hemorrhage risk in unruptured cases and 4.5% annual hemorrhage risk of previously ruptured cases. Stereotactic radiosurgery (SRS) have been shown excellent treatment outcomes for patients with small- to moderated sized AVM which can be achieved in 80-90% complete obliteration rate with a 2-3 years latency period. The most important factors are associated with obliteration after SRS is the radiation dose to the AVM. In our institutional clinical practice, now 22 Gy (50% isodose line) dose of radiation has been used for treatment of cerebral AVM in single-session radiosurgery. However, dose-volume relationship can be unfavorable for large AVMs when treated in a single-session radiosurgery, resulting high complication rates for effective dose. Thus, various strategies should be considered to treat large AVM. The role of pre-SRS embolization is permanent volume reduction of the nidus and treat high-risk lesion such as AVM-related aneurysm and high-flow arteriovenous shunt. Various staging technique of radiosurgery including volume-staged radiosurgery, hypofractionated radiotherapy and dose-staged radiosurgery are possible option for large AVM. The incidence of post-radiosurgery complication is varied, the incidence rate of radiological post-radiosurgical complication has been reported 30-40% and symptomatic complication rate was reported from 8.1% to 11.8%. In the future, novel therapy which incorporate endovascular treatment using liquid embolic material and new radiosurgical technique such as gene or cytokine-targeted radio-sensitization should be needed.

Effect of Low Dose of Gamma Radiation on the Growth of Groundnut (Arachis hypogaea L.) (저선량 감마선이 땅콩 생장에 미치는 효과)

  • 김재성;이은경;백명화;박홍숙;김광호
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.3
    • /
    • pp.257-261
    • /
    • 1999
  • Effect of low dose gamma radiation on the growth of groundnut (Arachis hypognea L.) were investigated with respect to germination rate, seedling development and yield. Seeds of “Palpal” cultivar were irradiated with 0.5~20 Gy of ${\gamma}$ radiation in order to determine the hermetic effect of low dose radiation. The germination rate of ${\gamma}$-ray irradiation group was lower than that of the control but the seedling height of groundnut grown from seeds irradiated with low dose ${\gamma}$-ray was slightly higher than that of the control. The number of pod and kernels, and the seed yield increased by 27%, 17% and 19 %, respectively, in the 12.0 Gy irradiation group compared to that in the control group. The 100 seed weight was 87.2 g in the 4.0 Gy irradiation group, which was 11% heavier than 78.3 g in the control group. Low dose radiation showed an enhancement effects on the growth and yield components of groundnut.

  • PDF

Electron beam scattering device for FLASH preclinical studies with 6-MeV LINAC

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Hee Chang;Lee, Kyohyun;Kim, Seung Heon;Lee, Dong Eun;Jang, Kyoung Won
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1289-1296
    • /
    • 2021
  • In this study, an electron-scattering device was fabricated to practically use the ultra-high dose rate electron beams for the FLASH preclinical research in Dongnam Institute of Radiological and Medical Sciences. The Dongnam Institute of Radiological and Medical Sciences has been involved in the investigation of linear accelerators for preclinical research and has recently implemented FLASH electron beams. To determine the geometry of the scattering device for the FLASH preclinical research with a 6-MeV linear accelerator, the Monte Carlo N-particle transport code was exploited. By employing the fabricated scattering device, the off-axis and depth dose distributions were measured with radiochromic films. The generated mean energy of electron beams via the scattering device was 4.3 MeV, and the symmetry and flatness of the off-axis dose distribution were 0.11% and 2.33%, respectively. Finally, the doses per pulse were obtained as a function of the source to surface distance (SSD); the measured dose per pulse varied from 4.0 to 0.2 Gy/pulse at an SSD range of 20-90 cm. At an SSD of 30 cm with a 100-Hz repetition rate, the dose rate was 180 Gy/s, which is sufficient for the preclinical FLASH studies.

Feasibility of clay-shielding material for low-energy photons (Gamma/X)

  • Tajudin, S.M.;Sabri, A.H.A.;Abdul Aziz, M.Z.;Olukotun, S.F.;Ojo, B.M.;Fasasi, M.K.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1633-1637
    • /
    • 2019
  • While considering the photon attenuation coefficient (${\mu}$) and its related parameters for photons shielding, it is necessary to account for its transmitted and reflected photons energy spectra and dose contribution. Monte Carlo simulation was used to study the efficiency of clay ($1.99g\;cm^{-3}$) as a shielding material below 150 keV photon. Am-241 gamma source and an X-ray of 150 kVp were calculated. The calculated value of ${\mu}$ for Am-241 is higher within 5.61% compared to theoretical value for a single-energy photon. The calculated half-value layer (HVL) is 0.9335 cm, which is lower than that of ordinary concrete for X-ray of 150 kVp. A thickness of 2 cm clay was adequate to attenuate 90% and 85% of the incident photons from Am-241 and X-ray of 150 kVp, respectively. The same thickness of 2 cm could shield the gamma source dose rate of Am-241 (1 MBq) down to $0.0528{\mu}Sv/hr$. For X-ray of 150 kVp, photons below 60 keV were significantly decreased with 2 cm clay and a dose rate reduction by ~80%. The contribution of reflected photons and dose from the clay is negligible for both sources.

Assessment of Potential Radiation Dose Rates to Marine Organisms Around the Korean Peninsula

  • Lee, Dong-Myung;Lee, Jun-ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Background: It is very difficult to set a regulatory guidance or criteria for the protection of non-human species from the ionizing radiation, because there are no generally or internationally accepted methods for demonstrating the compliance with such criteria. It is needed that Korea develop the primary dose rate standards for the protection of both aquatic and terrestrial biota in the near future. Materials and Methods: The potential dose rates due to both external and internal radiation exposures to marine organisms such as plaice/flounder, gray mullet, and brown seaweed collected within territorial seas around the Korean Peninsula were estimated. Results and Discussion: The total dose rates to plaice/flounder, gray mullet and brown seaweed due to $^{40}K$, a primordial radionuclide in marine environment, were found to be 0.2%, 0.08% and 0.3% of approximately the values of the Derived Consideration Reference Levels (DCRLs, i.e. $1-10mGy{\cdot}d^{-1}$), respectively, as suggested by the International Commission on Radiological Protection (ICRP) publication 124. The total dose rates to marine fishes and brown seaweed due to anthropogenic radionuclides such as $^{90}Sr$, $^{137}Cs$ and $^{239+240}Pu$ were considered to be negligible compared to the total dose rate due to $^{40}K$. The external exposure to benthic fish due to all radionuclides was much higher than that of pelagic fish. Conclusion: From this study, it is recommended that the further study is required to develop a national regulatory guidance for the evaluation of doses to non-human species.

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.

An Improved Methodology of Monetary Values of the Unit Collective Dose for Intervention Against Long-Term Exposure Following a Nuclear Accident (원자력 사고후 장기피폭에 대한 개입을 위한 피폭선량 금전가 산정의 개선된 방법론)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Choi, Young-Gil;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.77-80
    • /
    • 2002
  • A more practice approach for the determination of monetary values of the unit collective dose for intervention against long-term exposure following a nuclear accident was proposed. In addition, she monetary values of the unit collective dose estimated from the proposed approach were compared with those estimated from the previous model, which are derived from assumptions of routine exposure and the same values are applied in a nuclear accident without modification, using Korean economic data. The monetary values based on the proposed approach showed a distinct difference depending on inequity in the distribution of individual doses. The discounting rate was also an important factor in determination of monetary values of the unit collective dose.

Dose Determination in the IR-221 Gamma Facility Using a Monte Carlo Simulation (몬테칼로 시뮬레이션을 이용한 IR-221의 선량 평가)

  • Lim, Ik-Sung;Kim, Ki-Yup;Roh, Gyu-Hong;Lee, Chung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • This study is performed to evaluate the dose rate and to analyze the dose distribution of the gamma irradiation facility (IR-221) by using a Monte Calro simulation, which is helpful of upgrading the radiation processing qualification. Monte Cairo simulation is performed by MCNP4B code. Dose rates were measured at total 369 points with alanine dosimeters to compare the calculation results and the measurements data. The results have shown that the MCNP4B code is very useful to determine the dose distribution of the IR-221 gamma irradiation facility, as the calculation dose rate is within about ${\pm}5%$ of the measurement data. Dosimetry about the gamma irradiation facility usually needs enormous manpower and time. However Monte Cairo calculation method can reduce the tedious dosimetry jobs and improve the irradiation processing qualification, which will probably contribute to obtain the reliability of the irradiation products.

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF