• 제목/요약/키워드: Dose Distribution

검색결과 1,172건 처리시간 0.031초

전자담배용 니코틴 원액 음독 후 발생한 심정지 1례 (A Case Report of Cardiac Arrest Following Intentional Ingestion of Liquid Nicotine for Electronic Cigarette)

  • 김정호
    • 대한임상독성학회지
    • /
    • 제16권2호
    • /
    • pp.172-175
    • /
    • 2018
  • Acute nicotine poisoning by liquid nicotine for electronic cigarettes is becoming an increasing problem worldwide. On the other hand, there are no regulations regarding its concentration, container or labelling in Korea. This is the first case of a cardiac arrest after liquid nicotine ingestion that was confirmed by plasma nicotine detection in Korea. A 34-year-old male was found with a cardiac arrest at home by the emergency medical services crew, and had a return of spontaneous circulation after 27 minutes of cardio-pulmonary resuscitation. The cause of his cardiac arrest was suspected to be acute nicotine poisoning by the ingestion of liquid nicotine. Toxicology analysis of the National Forensic Service confirmed plasma nicotine, and the pharmacokinetic estimated average concentration of plasma nicotine at the time of the cardiac arrest was 29.7 mg/L, a lethal dose. He was hospitalized for further treatment, but was discharged after 20 days without any improvement. Considering the strong toxicity of nicotine, appropriate policy decisions are required for sales and distribution.

MRI-Guided Gadolinium Neutron Capture Therapy

  • Ji-Ae Park;Jung Young Kim;Hee-Kyung Kim
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.113-118
    • /
    • 2022
  • Gadolinium neutron capture therapy (Gd-NCT) is a precision radiation therapy that kills cancer cells using the neutron capture reaction that occurs when 157Gd hits thermal neutrons. 157Gd has the highest thermal neutron capture cross section of 254,000 barns among stable isotopes in the periodic table. Another stable isotope, 155Gd, also has a high thermal neutron trapping area (~ 60,700 barns), so gadolinium that exists in nature can be used as a Gd-NCT drug. Gd-NCT is a mixed kinetic energy of low-energy and high-energy ionizing particles, which can be uniformly distributed throughout the tumor tissue, thereby solving the disadvantage of heterogeneous dose distribution in tumor tissue. The Gd complexes of small-sized molecule are widely used as contrast agents for magnetic resonance imaging (MRI) in clinical practice. Therefore, these compounds can be used not only for diagnosis but also therapy when considering the concept of Gd-NCT. This multifunctional trial can look forward to new medical advance into NCT clinical practices. In this review, we introduce gadolinium compounds suitable for Gd-NCT and describe the necessity of image guided Gd-NCT.

Experimental Analysis of Superconducting Fault Current Limiter Wound with Two Different HTS wires in Parallel

  • Kim, Ji-Tae;Jang, Jae-Young;Park, Dong-Keun;Chang, Ki-Sung;Kim, Young-Jae;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.30-33
    • /
    • 2008
  • Several kinds of superconducting fault current limiters (SFCLs), which reduces huge fault current, have been developing by many research groups. The SFCL has no impedance during normal operation, so it dose not give any influence to electric power system. The resistive type SFCL reduces the fault current with the impedance generated in the superconducting part of the SFCL when the fault current exceeds the critical current of SFCL. In this paper, a new type resistive SFCL made of bifilar coil wound with two different high-Tc superconducting (HTS) wires in parallel. Although a bifilar coil has theoretically no inductance, the bifilar coil made in this paper could generate inductance at fault. The specifications of the used two wires were considerably different, thus current distribution between the two HTS wire was different at fault. When the fault current exceeded the critical current of one wire in the bifilar coil, the momentary sharp increase of impedance was detected. Base on the results, a new resistive type SFCL can generate not only resistance but also inductance, which can be used to control a fault current in the future.

鷄胎肥滿細胞에 미치는 Hyaluronidase 의 影響 (Effect of Hyaluronidase on Mast Cells of the Dveloping Chichk)

  • 하재청
    • 한국동물학회지
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 1969
  • 저자는 백색 레그혼의 種卵을 孵化시켜 얻은 10 日胚의 卵黃囊에 hyaluronidase 400$\mu$/kg를 單回 注射하여 皮膚 및 前胃肥滿細胞의 出現狀態와 細胞質顆粒의 변화를 經時的으로 관찰하여 다음과 같은 結果를 얻었다. 1. Hyaluronidase 투여로 鷄胎 肥滿細胞의 出現은 對照群에 비하여 상당히 지연되었다. 2. Hyaluronidase 투여후 6~7일에 肥滿細胞의 比較出現數는 對照群値의 약 반수를 보였으며 그후 회복되기 시작하여 7日雛에서 거의 對照群値를 나타냈다. 3. Hyaluronidase 투여로 肥滿細胞顆粒의 脫出은 거의 관찰되지 않았으며 顆粒의 分解로 染色性 減退가 현저 하였다. 이상의 관찰결과로 보아 hyaluronic acid는 肥滿細胞顆粒의 形成에 관련하는 것으로 사료된다.

  • PDF

The effect of sensitive and non-sensitive parameters on DCGL in probability analysis for decommissioning of nuclear facilities

  • Hyung-Woo Seo;Hyein Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3559-3570
    • /
    • 2023
  • In the decommissioning of nuclear facilities, Derived Concentration Guideline Level (DCGL) derivation is necessary for the release of the facility after the site remediation, which also needs to be implemented in the stage of establishing a decommissioning planning. In order to derive DCGL, the dose assessment for the receptors can be conducted from residual radioactivity by using RESRAD code. When performing sensitivity analysis on probabilistic parameters, secondary evaluation is performed by assigning a single value for parameters classified as sensitive. However, several options may arise in the handling of nonsensitive parameters. Therefore, we compared the results of the first execution of RESRAD applying probabilistic parameters for each scenario with the results of the second execution applying a single value to sensitive parameters among the probabilistic parameters. In addition, we analyzed the effect of setting options for non-sensitive parameters. As a result, the effect on DCGL were different depending on the application scenario, the target radionuclides, and the input parameter selections. In terms of the overall evaluation period, the DCGL graph of the default option was generally shown as the most conservative except for some radionuclides. However, it will not necessarily be given priority in the aspect of the need to reflect site characteristics. The reason for selecting a probabilistic parameter is the availability of the parameter and the uncertainty of applying a single value. Therefore, as an alternative, it can be consistently applied to distribution as an option for non-sensitive parameters after sensitivity analysis.

방사성폐기물 처분시설에서 생태계 모델의 입력데이터 선정에 대한 고찰 (Considerations on Screening for the Input Data of the Biosphere Model in the Radioactive Waste Disposal Facility)

  • 정미선;박동국;김수진;정강일
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.209-217
    • /
    • 2023
  • The biosphere has important function in the safety assessment of a radioactive waste disposal facility. A biosphere model in the safety assessment needs various input data that contain significantly inherent uncertainties. This paper reviews the effects of the input data on the radiological impact assessment from main radionuclides such as 14C and 99Tc in the biosphere model. In addition, it is confirmed that the safety criteria is met, when the conservative input data for the intake rate, soil to plant concentration ratio, and distribution coefficients of the radionuclides are applied and probabilistic analysis are conducted in the biosphere model. Nevertheless, it is required to generate site-specific input data for the confidence building and reduce excessive conservatism in the biosphere model.

밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과 (Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber)

  • 김진현;한충수;이근우;임경호;이재현;김경민;하유신
    • 생물환경조절학회지
    • /
    • 제23권1호
    • /
    • pp.1-10
    • /
    • 2014
  • 본 연구에서는 파장의 위상차를 변화시켜 균일한 살균을 유도할 수 있고 저전력으로 효과를 높일 수 있는 QRD(quadratic residue diffusor) 마이크로파를 이용하여 챔버 내부의 위치에 따른 온도변화를 측정하여 효율성과 균등성을 분석한 결과는 다음과 같다. 챔버 내부의 수직 35cm, 중앙 위치에서는 7kW 조사시 가장 효율이 높게 나타났고, 좌우측 위치에서는 5kW에서 효율성이 높았다. 그리고 마그네트론 No. 1, 2, 3에서 3kW로 하였을 때, Bar의 위치에 따른 온도 균등성은 1Bar와 2Bar의 위치에서는 거의 비슷하게 나타났다. 마그네트론 No. 3, 4, 5의 3kW로 하였을 경우에는 3Bar에서 온도가 약 10~20% 정도 높게 나타났고 마그네트론 용량을 5, 7, 9kW로 하였을 때, 조사 시간에 대한 평균 온도는 Bar의 위치에 무관하게 거의 유사한 형태로 증가하였다. 반면에 챔버의 적정 내용적에 대한 효율성은 조사용량에 반드시 비례하지는 않았다. 마그네트론 3kW를 60, 120, 180초 동안 조사하였을 경우 마그네트론 조사 위치에 따라 구석 부분에서 약 $5{\sim}10^{\circ}C$ 더 높게 상승하였고 수평면의 위치별 온도 분포는 비교적 균일하였으며 부분적으로 구석부분에서 약간 더 온도가 상승하는 경향이 있었다. 마그네트론 5, 7, 9kW 조사에서는 Bar의 위치와 상관없이 전반적으로 온도가 비교적 균일하게 상승하고 있었다.

EWHA Breast Device(EBD)의 제작 및 유용성 평가 (The evaluation of custo-made EWHA Breast Device(EBD))

  • 변영식;오태성;박종일;신현교
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.33-40
    • /
    • 2005
  • 목적 : 3D conformal, IMRT와 같은 치료기술의 개발로 인하여 CT를 이용한 최신의 치료들이 적용되어지고 있는 것이 지금의 현실이지만, 유방암 환자에서는 일반 CT의 hole size의 제약으로 인하여 일부의 경우는 기존의 환자고 정기구들이 사용되어지지 못하고 있다. 또한 simulation 시에 수술한 팔을 장시간 올리고 있는 자세를 유지함으로써 환자들이 pain을 호소하고, SCL (supraclavicular Imphnodes) 치료 시에 skin reaction의 문제점이 제기되었다. 이에 본원에서는 이러한 문제점을 개선하기 위하여 Ewha Breast device (EBD)를 자체 제작하여 사용하였으며, 이번 논제에서는 EBD의 제작과 유용성의 평가에 대하여 논하고자 한다. 대상 및 방법 : CT data를 이용하여 머리의 크기를 분석하였으며, 일반 CT의 hole size, 자세의 안정성, SCL field에서의 피부의 겹침(fold) 등을 고려하여 아크릴로 device를 제작하였으며 기존의 device를 사용하였을 경우와 set-up의 재현성, RTP상의 dose분포, SCL field에서의 skin reaction 등을 비교 분석하여 EBD의 유용성에 대하여 평가하였다. 결과 : 제작한 EBD를 사용 시 CT simulator가 아닌 hole size가 작은 일반 CT에서도 팔의 부딪힘이 없이 자세를 유지할 수 있었고, 위로 올린 팔의 pain도 많이 감소하였다. 그리고, 기존의 device와 비교하였을 경우에 set-up의 재현성에서 큰 차이를 보이지 않았으며, RTP상에서는 3D segment field를 이용한 plan으로 device의 tilting이 되지 않은 문제점은 해결할 수 있었으나 기존보다 팔을 많이 위로 올리지 않는 관계로 axillary region에서 이전보다 약$10\%$ 정도의 선량이 더 들어감을 알 수 있었다. SCL field에서의 skin reaction은 접힌 부분(fold)을 펼치기 위해 팔을 조정하여 위치를 잡는 관계로 이전보다 월등히 적은 skin reaction이 발생함을 알 수 있었다. 결론 : 비용이 저렴한 EBD의 제작으로 유방암 환자에서 CT를 이용한 3D 치료가 용이하게 되었으며, simulation 시에 팔의 pain을 경감시킬 수 있었고, skin reaction의 감소 등으로 치료에 EBD를 유용하게 사용할 수 있었다. 앞으로 EBD를 사용하여 나타난 device의 문제점 등을 보완 수정한다면 치료에 더 많은 도움이 되리라 생각된다.

  • PDF

양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교 (Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy)

  • 김경태;김선영;김대웅;김재원;박지연;전상민
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.43-49
    • /
    • 2019
  • 목 적: 움직이는 장기에 취약한 Pencil Beam Scanning(PBS)을 보완하기 위해 고안된 Layered Rescanning PBS 기법을 Moving Phantom에 적용하여 Single Scan PBS와 선량비교를 통해 Homogeneity를 비교해 본다. 대상 및 방법: Matrix X(IBA, Belgium)와 Moving Phantom(standard imaging, USA)을 이용하였다. 가상의 tumor $10{\times}10{\times}5cm$에 AP 방향에서 200 cGy의 선량을 조사하였다. 치료계획은 single scan PBS, rescan 4, 8, 12회 총 4가지로 하였고 각 치료계획별로 3번씩 반복 측정하였다. 측정 시 Moving Phantom의 호흡주기는 한 cycle당 4초로 설정 후 S-I 방향 움직임 2 cm으로 설정하였다. 추가로 beam on time을 측정하였다. 결 과: PTV 내에서 $D_{max}$의 평균값은 single scan, 4, 8, 12회 rescan 순서로 각각 $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ $D_{min}$의 평균값은 각각 $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$으로 $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$으로 측정되었다. 그리고 rescan 횟수가 늘어날수록 Homogeneity Index가 1에 가까워졌으며, beam on time은 평균 2분 15초, 3분 15초, 4분 30초, 5분 37초로 rescan 횟수가 증가할수록 치료시간이 증가되었다. 측정하는 과정에서 MU가 낮은 선량 layer에서는 설정한 rescan 횟수만큼 실제로 rescan하지 못하는 문제점이 발견되었다. 결 론: 장기 움직임이 있는 종양 치료 시 Layered Rescanning PBS을 적용했을 때 single scan PBS보다 균일한 선량분포를 확인할 수 있었다. 그리고 rescan 횟수가 증가할수록 균일한 선량분포를 보였다. single scan PBS와 12회 Layered rescanning 비교 시 HI 수치가 0.32 향상되었다. 추후 연구를 통하여 호흡동조 방사선치료가 불가능환자에게 적용이 가능할 것으로 사료된다.

Quantitative Microbial Risk Assessment for Clostridium perfringens in Natural and Processed Cheeses

  • Lee, Heeyoung;Lee, Soomin;Kim, Sejeong;Lee, Jeeyeon;Ha, Jimyeong;Yoon, Yohan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권8호
    • /
    • pp.1188-1196
    • /
    • 2016
  • This study evaluated the risk of Clostridium perfringens (C. perfringens) foodborne illness from natural and processed cheeses. Microbial risk assessment in this study was conducted according to four steps: hazard identification, hazard characterization, exposure assessment, and risk characterization. The hazard identification of C. perfringens on cheese was identified through literature, and dose response models were utilized for hazard characterization of the pathogen. For exposure assessment, the prevalence of C. perfringens, storage temperatures, storage time, and annual amounts of cheese consumption were surveyed. Eventually, a simulation model was developed using the collected data and the simulation result was used to estimate the probability of C. perfringens foodborne illness by cheese consumption with @RISK. C. perfringens was determined to be low risk on cheese based on hazard identification, and the exponential model ($r=1.82{\times}10^{-11}$) was deemed appropriate for hazard characterization. Annual amounts of natural and processed cheese consumption were $12.40{\pm}19.43g$ and $19.46{\pm}14.39g$, respectively. Since the contamination levels of C. perfringens on natural (0.30 Log CFU/g) and processed cheeses (0.45 Log CFU/g) were below the detection limit, the initial contamination levels of natural and processed cheeses were estimated by beta distribution (${\alpha}1=1$, ${\alpha}2=91$; ${\alpha}1=1$, ${\alpha}2=309$)${\times}$uniform distribution (a = 0, b = 2; a = 0, b = 2.8) to be -2.35 and -2.73 Log CFU/g, respectively. Moreover, no growth of C. perfringens was observed for exposure assessment to simulated conditions of distribution and storage. These data were used for risk characterization by a simulation model, and the mean values of the probability of C. perfringens foodborne illness by cheese consumption per person per day for natural and processed cheeses were $9.57{\times}10^{-14}$ and $3.58{\times}10^{-14}$, respectively. These results indicate that probability of C. perfringens foodborne illness by consumption cheese is low, and it can be used to establish microbial criteria for C. perfringens on natural and processed cheeses.