• 제목/요약/키워드: Dose Constant

검색결과 262건 처리시간 0.029초

라돈 환경계통의 제어 매개변수 모델링 (Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters)

  • 주운표;김건중;장시영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

약품 주입비율에 따른 하수 슬러지 형태(소화·비소화)가 건조효율에 미치는 영향 - 근적외선 및 마이크로파를 중심으로 - (Effect on Drying Efficiency of the Sewage Sludge (Digested, non digested) according to Polymer dose Ratio - Focus on the NIR and Microwave -)

  • 이승원
    • 한국환경과학회지
    • /
    • 제30권3호
    • /
    • pp.245-255
    • /
    • 2021
  • In this study, we evaluated the effect of the type of sewage sludge (digested, non digested) on drying efficiency according to the polymer injection rate. The drying characteristics were shown using a near-infrared ray (NIR) and a microwave. As a result of the drying characteristics with NIR at a polymer dose ratio of 8%, the heating up period is up to 6 minutes after the start of the drying experiment. Afterwards, the constant rate drying period of the digested sludge (A, C and G sites) was 6 minute → 18 minute, showing a rapid decrease in moisture. On the other hand, non digested sludge (B, D, E, F, H, I, J and K sites) showed gradual drying characteristics compared to digested sludge until complete drying (10%). As the polymer dose ratio of 10% and 12%, the heating up period for digested sludge is up to 6 minute after the start of the experiment. Afterwards, the constant rate drying period of the digested sludge was 6 minute → 20 minute, showing a rapid decrease in moisture. On the other hand, the heating up period of non digested sludge was up to 10 minute after the start of the experiment, and the constant rate drying period was 10 minute → 22 minute, which was shorter than digested sludge. As a result of the drying characteristics with microwave at a polymer dose ratio of 8%, 10% and 12%, the constant rate drying period the digested sludge was 4 minute → 20~22 minute, showing a rapid decrease in moisture. On the other hand, non digested sludge of the constant rate drying period was 4 minute → 22~30 minute, which was longer than digested sludge.

코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성 (Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source)

  • 최태진;이호준;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.259-266
    • /
    • 1998
  • 코발트-60 근접조사선원을 대체할 Ir-l92 선원주변의 2차원적 선량분포를 얻기 위하여, 조사선량률과, 조직감쇠계수를 구하였다. 조직감쇠계수는 선원에서 20 cm 지점까지 실험식을 구하였다. ?보기 방사능은 조사선량상수를 사용하여 결정하였으며, 2.5mm 직경에 두께 2.5 mm 의 선원은 조직선량을 정하기 위해 선원을 4401 개로 분할하여 선원 자체의 흡수효과와 ?슐벽의 차폐 효과와 조직감쇠계수를 적용하였다. 조직감쇠계수는 4차식을 사용하여 1% 오차범위내에서 실험값을 얻을 수 있었으며, Meisberger 상수는 선원에서 많이 떨어질수록 오차가 커서, 10 cm 위치서 7%, 20 cm 에서 33%의 오차를 발견할 수 있었으나, 겉보기방사능과 선원모양 및 크기가 달라 다른 결과를 가져올 수 있다고 본다. 발표된 Ir-192 선원의 에너지스펙트럼을 이용한 선량률상수는 절삭에너지 10 keV인 경우 4.69 R$cm^2$/mCi-hr을 얻었으며 Air Kerma는 0.973 을 구하였다. 이 실험에서 고안 선원의 분할선원에 의한 선원자체흡수와 ?슐벽에 의한 감쇠는 실선원의 54.6%가 겉보기방사능으로 나타남을 알 수 있었으며, 선량계획에 이용하기 위해 단위 ?보기 방사능에 대한 2차원적 선량표를 준비함으로써 기하학적선량과 선량 비등방성을 쉽게 이용할 수 있도록 하였다.

  • PDF

UV/H2O2 고도산화기술을 이용한 수중 잔류의약물질 제거 (Degradation of residual pharmaceuticals in water by UV/H2O2 advanced oxidation process)

  • 박진영;서상원;조익환;전용성;하현섭;황태문
    • 상하수도학회지
    • /
    • 제33권6호
    • /
    • pp.469-480
    • /
    • 2019
  • This study was conducted to evaluate the degradation and mineralization of PPCPs (Pharmaceuticals and Personal Care Products) using a CBD(Collimated Beam Device) of UV/H2O2 advanced oxidation process. The decomposition rate of each substance was regarded as the first reaction rate to the ultraviolet irradiation dose. The decomposition rate constants for PPCPs were determined by the concentration of hydrogen peroxide and ultraviolet irradiation intensity. If the decomposition rate constant is large, the PPCPs concentration decreases rapidly. According to the decomposition rate constant, chlortetracycline and sulfamethoxazole are expected to be sufficiently removed by UV irradiation only without the addition of hydrogen peroxide. In the case of carbamazepine, however, very high UV dose was required in the absence of hydrogen peroxide. Other PPCPs required an appropriate concentration of hydrogen peroxide and ultraviolet irradiation intensity. The UV dose required to remove 90% of each PPCPs using the degradation rate constant can be calculated according to the concentration of hydrogen peroxide in each sample. Using this reaction rate, the optimum UV dose and hydrogen peroxide concentration for achieving the target removal rate can be obtained by the target PPCPs and water properties. It can be a necessary data to establish design and operating conditions such as UV lamp type, quantity and hydrogen peroxide concentration depending on the residence time for the most economical operation.

카르바마제핀의 체내동태에 대한 신장해의 영향 (Effect of Renal Failure on Pharmacokinetics of Carbamazepine in Rabbits)

  • 이종기;박현진;조행남
    • 한국임상약학회지
    • /
    • 제9권2호
    • /
    • pp.92-96
    • /
    • 1999
  • The pharmacokinetics of carbamazepine(100 mg/kg, oral) in the folic acid-induced renal failure rabbits was studied. Renal failure was induced by the i.v. injection of folic acid (50, 100, and 200 mg/kg). At folic acid dose of 100 and 200 mg/kg, the serum creatinine concentration (Scr) and blood urea nitrogen (BUN) increased significantly compared with control rabbits. Plasma concentrations and area under the plasma level-time curve (AUC) of carbamazepine increased significantly at folic acid dose of 100 and 200 mg/kg. The elimination rate constant (Kel) of carbamazepine decreased significantly, and half-life $(t_{1/2})$ of carbamazepine increased significantly at folic acid dose of 100 and 200 mg/kg. The serum creatinine concentration (Scr) correlated well with AUC and elimination rate constant (Kel) of carbamazepine, as well as BUN with AUC and elimination rate constant (Kel) of carbamazepine. These results suggest that adjustment of the dosage regimen of carbamazepine is desirable, and serum creatinine concentration (Scr) as well as BUN can be used for adjusting the dosage regimen of carbamazepine in renal failure.

  • PDF

방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定) (The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials)

  • 허준;김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

Prediction of drug-Drug Interaction During Oral Absorption of Carrier-Mediated Compounds in Humans

  • Oh, Doo-Man;Gordon L. Amidon
    • Archives of Pharmacal Research
    • /
    • 제17권5호
    • /
    • pp.364-370
    • /
    • 1994
  • A microscopic mass balance approach has been developed to estimate the extent and rate of absorption for camier-mediated comounds. For the case competitive inhibition in the presence of an inhibitor which shares the same camier, the fraction dose absorbed (F) and absorption rate constant ($K_a$) of a drug can be calculated from its concentration profile in the intestinal lumen. Absorption parameters obtained by single-pass perfusion experiments were used in the simultaion of the absorption of some aminopenicilins. Predicted fractions dose absorbed and absorption rate constants of ampicilin and amoxicilin were significantly reduced in the presence of a 6-times higher molar dose of cyclacilin. The drug-drug interactions on the competitive absroption of camier-mediated compounds were determined with regard to F and $K_a$. Predicted decreases in F for some aminopenicilins corrlated well with decrease in the urinary recovery in humans reported in the literature. Predicted decrease in the mean absorption rate constant ($\barK_a$) explain the delays in the time of peak plasma concentration ($T_{max}$) reported in humans.

  • PDF

에탄올과 Sulfamethazine의 약물상호작용 (Drug Interaction of Sulfamethazine and Ethanol)

  • 최준식;전종철;이진환;유영종
    • Journal of Pharmaceutical Investigation
    • /
    • 제16권1호
    • /
    • pp.31-35
    • /
    • 1986
  • Effect of ethanol on the absorption rate, blood level and bioavailability of sulfamethazine (SM) in rats was determined. Absorption rate of SM was determined both by the in vitro and in situ experiment. In vitro, absorption rate of SM in rat small intestine was increased by 0.3, 1.0 and 3.0% ethanol. In situ, absorption rate of SM was increased by 0.3 and 1.0% ethanol but not by 3.0% ethanol. After oral administration, blood level of SM was elevated and relative bioavailability was significantly increased to 114.8% at the dose of 0.6g/kg ethanol but not significantly at the dose of 3.0g/kg ethanol. The time for attainment of peak blood level was changed from 2.5 to 1.5hr. Ethanol enhanced absorption rate constant of SM significantly and reduced elimination rate constant of SM administered orally at the dose of 0.6g/kg ethanol.

  • PDF

$\gamma$선조사에 의한 B종절연재료의 전기적 특성변화에 대한 실험적 연구 (The experimental study of $\gamma$ ray irradiation effect on electrical properties of B-kind insulator)

  • 천희영;성영권;이덕출
    • 전기의세계
    • /
    • 제18권2호
    • /
    • pp.15-20
    • /
    • 1969
  • The main focus of this paper is on the study of the .gamma. ray irradiation effect upon the electrical properties of a B-kind insulator which is one of the inorganic insulators. The mica is so typical of the B kind insulators as to be selected for a sample. DC, AC, and Impulse voltage is applied to the variable .gamma. ray irradiated dose samples with the constant time duration and the time variable samples with the .gamma. ray irradiated dose. The dielectric breakdown voltage and dielectric constant are measured from the samples and we get the experimental data that the dielectric breakown voltage variations are relatively large, but the dielectric constants are almost constant. The above conclusion is useful for the selection and application of the inorganic insulators under the irradiation effects, and we expect that the conclusion can apply to not only B-kind insulators but also the inorganic insulators.

  • PDF

고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성 (Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations)

  • 최태진;김옥배;노홍균
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF