• Title/Summary/Keyword: Dose Constant

Search Result 262, Processing Time 0.028 seconds

Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters (라돈 환경계통의 제어 매개변수 모델링)

  • Zoo, Oon-Pyo;Kim, Kem-Joong;Chang, Si-Young
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

Effect on Drying Efficiency of the Sewage Sludge (Digested, non digested) according to Polymer dose Ratio - Focus on the NIR and Microwave - (약품 주입비율에 따른 하수 슬러지 형태(소화·비소화)가 건조효율에 미치는 영향 - 근적외선 및 마이크로파를 중심으로 -)

  • Lee, Seung-Won
    • Journal of Environmental Science International
    • /
    • v.30 no.3
    • /
    • pp.245-255
    • /
    • 2021
  • In this study, we evaluated the effect of the type of sewage sludge (digested, non digested) on drying efficiency according to the polymer injection rate. The drying characteristics were shown using a near-infrared ray (NIR) and a microwave. As a result of the drying characteristics with NIR at a polymer dose ratio of 8%, the heating up period is up to 6 minutes after the start of the drying experiment. Afterwards, the constant rate drying period of the digested sludge (A, C and G sites) was 6 minute → 18 minute, showing a rapid decrease in moisture. On the other hand, non digested sludge (B, D, E, F, H, I, J and K sites) showed gradual drying characteristics compared to digested sludge until complete drying (10%). As the polymer dose ratio of 10% and 12%, the heating up period for digested sludge is up to 6 minute after the start of the experiment. Afterwards, the constant rate drying period of the digested sludge was 6 minute → 20 minute, showing a rapid decrease in moisture. On the other hand, the heating up period of non digested sludge was up to 10 minute after the start of the experiment, and the constant rate drying period was 10 minute → 22 minute, which was shorter than digested sludge. As a result of the drying characteristics with microwave at a polymer dose ratio of 8%, 10% and 12%, the constant rate drying period the digested sludge was 4 minute → 20~22 minute, showing a rapid decrease in moisture. On the other hand, non digested sludge of the constant rate drying period was 4 minute → 22~30 minute, which was longer than digested sludge.

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Degradation of residual pharmaceuticals in water by UV/H2O2 advanced oxidation process (UV/H2O2 고도산화기술을 이용한 수중 잔류의약물질 제거)

  • Park, Chinyoung;Seo, Sangwon;Cho, Ikhwan;Jun, Yongsung;Ha, Hyunsup;Hwang, Tae-Mun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.469-480
    • /
    • 2019
  • This study was conducted to evaluate the degradation and mineralization of PPCPs (Pharmaceuticals and Personal Care Products) using a CBD(Collimated Beam Device) of UV/H2O2 advanced oxidation process. The decomposition rate of each substance was regarded as the first reaction rate to the ultraviolet irradiation dose. The decomposition rate constants for PPCPs were determined by the concentration of hydrogen peroxide and ultraviolet irradiation intensity. If the decomposition rate constant is large, the PPCPs concentration decreases rapidly. According to the decomposition rate constant, chlortetracycline and sulfamethoxazole are expected to be sufficiently removed by UV irradiation only without the addition of hydrogen peroxide. In the case of carbamazepine, however, very high UV dose was required in the absence of hydrogen peroxide. Other PPCPs required an appropriate concentration of hydrogen peroxide and ultraviolet irradiation intensity. The UV dose required to remove 90% of each PPCPs using the degradation rate constant can be calculated according to the concentration of hydrogen peroxide in each sample. Using this reaction rate, the optimum UV dose and hydrogen peroxide concentration for achieving the target removal rate can be obtained by the target PPCPs and water properties. It can be a necessary data to establish design and operating conditions such as UV lamp type, quantity and hydrogen peroxide concentration depending on the residence time for the most economical operation.

Effect of Renal Failure on Pharmacokinetics of Carbamazepine in Rabbits (카르바마제핀의 체내동태에 대한 신장해의 영향)

  • Lee, Chong Ki;Park, Hyun Jin;Cho, Heng Nam
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.2
    • /
    • pp.92-96
    • /
    • 1999
  • The pharmacokinetics of carbamazepine(100 mg/kg, oral) in the folic acid-induced renal failure rabbits was studied. Renal failure was induced by the i.v. injection of folic acid (50, 100, and 200 mg/kg). At folic acid dose of 100 and 200 mg/kg, the serum creatinine concentration (Scr) and blood urea nitrogen (BUN) increased significantly compared with control rabbits. Plasma concentrations and area under the plasma level-time curve (AUC) of carbamazepine increased significantly at folic acid dose of 100 and 200 mg/kg. The elimination rate constant (Kel) of carbamazepine decreased significantly, and half-life $(t_{1/2})$ of carbamazepine increased significantly at folic acid dose of 100 and 200 mg/kg. The serum creatinine concentration (Scr) correlated well with AUC and elimination rate constant (Kel) of carbamazepine, as well as BUN with AUC and elimination rate constant (Kel) of carbamazepine. These results suggest that adjustment of the dosage regimen of carbamazepine is desirable, and serum creatinine concentration (Scr) as well as BUN can be used for adjusting the dosage regimen of carbamazepine in renal failure.

  • PDF

The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials (방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定))

  • Huh, Joon;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

Prediction of drug-Drug Interaction During Oral Absorption of Carrier-Mediated Compounds in Humans

  • Oh, Doo-Man;Gordon L. Amidon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.364-370
    • /
    • 1994
  • A microscopic mass balance approach has been developed to estimate the extent and rate of absorption for camier-mediated comounds. For the case competitive inhibition in the presence of an inhibitor which shares the same camier, the fraction dose absorbed (F) and absorption rate constant ($K_a$) of a drug can be calculated from its concentration profile in the intestinal lumen. Absorption parameters obtained by single-pass perfusion experiments were used in the simultaion of the absorption of some aminopenicilins. Predicted fractions dose absorbed and absorption rate constants of ampicilin and amoxicilin were significantly reduced in the presence of a 6-times higher molar dose of cyclacilin. The drug-drug interactions on the competitive absroption of camier-mediated compounds were determined with regard to F and $K_a$. Predicted decreases in F for some aminopenicilins corrlated well with decrease in the urinary recovery in humans reported in the literature. Predicted decrease in the mean absorption rate constant ($\barK_a$) explain the delays in the time of peak plasma concentration ($T_{max}$) reported in humans.

  • PDF

Drug Interaction of Sulfamethazine and Ethanol (에탄올과 Sulfamethazine의 약물상호작용)

  • Choi, Jun-Shik;Chun, Jong-Churl;Lee, Jin-Hwan;Yu, Young-Jong
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.1
    • /
    • pp.31-35
    • /
    • 1986
  • Effect of ethanol on the absorption rate, blood level and bioavailability of sulfamethazine (SM) in rats was determined. Absorption rate of SM was determined both by the in vitro and in situ experiment. In vitro, absorption rate of SM in rat small intestine was increased by 0.3, 1.0 and 3.0% ethanol. In situ, absorption rate of SM was increased by 0.3 and 1.0% ethanol but not by 3.0% ethanol. After oral administration, blood level of SM was elevated and relative bioavailability was significantly increased to 114.8% at the dose of 0.6g/kg ethanol but not significantly at the dose of 3.0g/kg ethanol. The time for attainment of peak blood level was changed from 2.5 to 1.5hr. Ethanol enhanced absorption rate constant of SM significantly and reduced elimination rate constant of SM administered orally at the dose of 0.6g/kg ethanol.

  • PDF

The experimental study of $\gamma$ ray irradiation effect on electrical properties of B-kind insulator ($\gamma$선조사에 의한 B종절연재료의 전기적 특성변화에 대한 실험적 연구)

  • 천희영;성영권;이덕출
    • 전기의세계
    • /
    • v.18 no.2
    • /
    • pp.15-20
    • /
    • 1969
  • The main focus of this paper is on the study of the .gamma. ray irradiation effect upon the electrical properties of a B-kind insulator which is one of the inorganic insulators. The mica is so typical of the B kind insulators as to be selected for a sample. DC, AC, and Impulse voltage is applied to the variable .gamma. ray irradiated dose samples with the constant time duration and the time variable samples with the .gamma. ray irradiated dose. The dielectric breakdown voltage and dielectric constant are measured from the samples and we get the experimental data that the dielectric breakown voltage variations are relatively large, but the dielectric constants are almost constant. The above conclusion is useful for the selection and application of the inorganic insulators under the irradiation effects, and we expect that the conclusion can apply to not only B-kind insulators but also the inorganic insulators.

  • PDF

Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations (고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성)

  • 최태진;김옥배;노홍균
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF