• Title/Summary/Keyword: Dose Coefficient

Search Result 263, Processing Time 0.028 seconds

Detection of Irradiated Model Food Containing Salt by Thermoluminescence Measurement

  • Chung, Hyung-Wook;Kwon, Joong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.1
    • /
    • pp.22-26
    • /
    • 1998
  • Model food containing common salt(NaCl) was subjected to the thermoluminescene(TL) detection whether it is irradiated or not. Salt irradiated with $^60Co$-gamma ray and electron beam exhibited a characteristic TL gowcurve depending on the irradiation dose, showing major peaks at $206^{\circ}C$ and $326^{\circ}C$. The intensity of TL glowcurves was directly proportional to the irradiated doses regardless of irradiation sources at each concentration of salt. A high correlation coefficient was observed for irradiated salt between the irradiation doses and the corresponding TL responses. At the same dose, the intensity of TL glowcurve increased as the concentration of salt increased in the test sample. TL glowcurves of nonirradiated salt and irradiated model food without salt were negligible and similar to a baseline . However, irradiated model food containing salt gave rise to a characteristic TL glowcurve with two major peaks at about $240^{\circ}C$ and $300^{\circ}C$, respectively. The results showed that salt played a role as an internla as well as external indicator in TL measurements, indicating that TL will be applicable to other condiments and spices with salt for their detection whether they are irradiated or not.

  • PDF

Preliminary Post-closure Safety Assessment of Disposal System for Disused Sealed Radioactive Source (폐밀봉선원 처분시스템 예비 폐쇄후 안전성평가)

  • Lee, Seunghee;Kim, Juyoul
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.4
    • /
    • pp.33-48
    • /
    • 2017
  • An optimum disposal plan of disused sealed radioactive sources (DSRSs) should be established to ensure long-term disposal safety at the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju. In this study, an optimum disposal system was suggested and preliminary post-closure safety assessment was performed. The DSRSs disposal system was composed of a rock cavern and near surface disposal facilities at the Gyeongju LILW disposal facility. The assessment was conducted using GoldSim program, and probabilistic assessment and sensitivity analysis were implemented to evaluate the uncertainties in the input parameters of natural barriers. Deterministic and probabilistic calculations indicated that the maximum dose was below the regulatory limits ($0.1mSvyr^{-1}$ for the normal scenario, $1mSvyr^{-1}$ for the well scenario). It was concluded that the DSRSs disposal system would maintain environmental safety over a long-time. Moreover, the partition coefficient of Np in host rock, Darcy velocity in host rock, and density of the host rock were the most sensitive parameters in predicting exposure dose in the safety assessment.

Estimation of radiostrontium, radiocesium and radiobarium transfer from arid soil to plant: A case study from Kuwait

  • Aba, Abdulaziz;Ismaeel, Anfal;Al-Boloushi, Omar
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.960-966
    • /
    • 2021
  • A technical approach to design and carry out an experiment to determine the uptake of selected radionuclides in site-specific conditions in Kuwait was developed and successfully executed for developing a radioecological decision support system. The radionuclides from soil-to-plant transfer factors have been obtained for leafy and non-leafy vegetables, and root crops cultivated in Kuwait. Two types of vegetated soils were selected and spiked with high concentrations of three relatively short-lived selected radionuclides (85Sr, 134Cs, and 133Ba). The highest strontium and barium transfer factors were found in the order: leafy vegetables > root crops > non-leafy vegetables. The approximate range of radiocesium transfer factor was found to be low in all plant groups and was comparable to those reported elsewhere in different soil types of temperate and tropical environments. A strong negative correlation between the obtained transfer factors and the distribution coefficient of the radionuclide in soil was found. It is recommended to adopt the newly derived parameters for the sensitive areas in Kuwait and other Gulf countries instead of using the generic parameters, whenever dose calculation codes are used. This will help to more accurately assess and predict the end results of the committed effective dose equivalent through ingestion pathway.

Calculation of X-ray spectra characteristics and kerma to personal dose equivalent Hp(10) conversion coefficients: Experimental approach and Monte Carlo modeling

  • Arectout, A.;Zidouh, I.;Sadeq, Y.;Azougagh, M.;Maroufi, B.;Chakir, E.;Boukhal, H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.301-309
    • /
    • 2022
  • This work aims to establish some X-ray qualities recommended by the International Standard Organization (ISO) using the half-value layer (HVL) and Hp(10) dosimetry approaches. The HVL values of the following qualities N-60, N-80, N-100, N-150 and N-250 were determined using various attenuation layers. The obtained results were compared to those of reference X-ray beam qualities and a good agreement was found (difference less than 5% for all qualities). The GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations) radiation transport Monte Carlo toolkit was employed to simulate the production of X-ray spectra. The characteristics HVLs, mean energy and the spectral resolution of simulated spectra have been calculated and turned out to be conform to the ISO reference ones (difference less than the limit allowed by ISO). Furthermore, the conversion coefficients from air kerma to personal dose equivalent for simulated and measured spectra were fairly similar (the maximum difference less than 4.2%).

Study on Dosimetry Used TLD Dosimeter and Body Mass Index at Total Body Irradiation (전신조사방사선치료에서 열형광선량계를 이용한 선량 측정과 체질량지수에 관한 고찰)

  • Seo, Dong-Rin;Kim, Yeon-Soo;Kim, Dae-Sup;Yoon, Hwa-Ryong;Back, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • Purpose: The aim of study is to expose a more uniform dose depending on the relationship between a body mass index in patients who underwent radiation therapy and an acquired dosimetric information by using a thermoluminescent dosimeter. Materials and Methods: Since 2006 to August 2011 we investigated 28 people who underwent radiation therapy were enrolled in AMC. Each patient was measured on the head, neck, chest, abdomen, pelvis, thigh, knee joint, and ankle joint using the thermoluminescent dosimeter. The measurement value of each points compared with the prescribed center point, abdominal point, and dose measurements of points on which to base the abdomen and the patient's body mass index (BMI) were compared with reference point, abdomen dose. Results: 28 patients on prescribed dose in the abdomen by which the center point, an average dose was $100.6{\pm}5.5%$, and the other seven measuring points with the average maximum difference among the head, neck, chest, pelvic, thigh, knee, and ankle were $92.8{\pm}4.2%$, $97.6{\pm}6.2%$, $96.4{\pm}5.5%$, $102.6{\pm}5.3%$, $103.4{\pm}7.9%$, $95.8{\pm}5.9%$, $96.1{\pm}5.5%$. The relationship of abdominal point dose and the patient's body mass index (BMI) was analyzed a scatter plot, and the result of linear relationship analysis by regression method, the regression of the dose (y) was -1.009 BMI (x) plus 123.3 and coefficient of determination ($R^2$) was represented 0.697. Conclusion: The total body irradiation treatment process was evaluated the dose deviation and then the prescribed dose by which the average abdominal dose was satisfied with $100.6{\pm}5.5%$. Results of the relationship analysis between BMI and dose, if we apply the correction value for each patients, it can be achieved more uniform dose delivery.

  • PDF

Studies on Synthesis, Hydrolysis and Oral Absorption of Piperacillin Phthalidyl Ester (피페라실린프탈리딜에스텔의 합성, 가수분해 및 경구흡수에 관한 연구)

  • Park, Gee-Bae;Choi, Seung-Ho;Choi, Young-Wook;Kim, Johng-Kap
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.3
    • /
    • pp.139-144
    • /
    • 1988
  • Piperacillin phthalidyl ester was synthesized by reacting piperacillin with triethylamine and bromophthalide in acetone and its chemical structure was determined by UV, IR, and PMR. The partition coefficient of the ester was increased and the ester was more lipophilic and less water soluble than piperacillin. The ester did not show the antimicrobial activity against Bacillus subtilis ATCC 6633 in vitro, but when hydrolyzed, the parent drug of ester, piperacillin, revealed antimicrobial activity in vivo. After a single oral dose of both piperacillin and the ester to rabbits, the serum piperacillin concentration was measured by bioassay. The ester exhibited improved pharmatokinetic characteristics: $T_{max}\;of\;2hr,\;C_{max}\;of\;4.26{\mu}g{\cdot}ml^{-1},K_{el}\;of\;0.057hr^{-1},\;and\;total\;AUC\;of\;85.42{\mu}g{\cdot}hr{\cdot}ml^{-1}$. Piperacillin on the other hand, did not exhibit any gastro-intestinal absorption.

  • PDF

A Study of B-implanted n Type Si Epi Resistor for the Fabrication of Thermal Stable Pressure Sensor (열적 안정한 압력센서 제작을 위한 보론(B) 이온 주입 n형 Si 에피 전극 연구)

  • Choi, Kyeong-Keun;Kang, Moon Sik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.40-46
    • /
    • 2018
  • In this paper, we focus on optimization of a boron ($^{11}B$)-implanted n type Si epi substrate for obtaining near-zero temperature coefficient of resistance (TCR) at temperature range from 25 to $125^{\circ}C$. The $^{11}B$-implantation on the N type-Si epi substrate formed isolation from the rest of the N-type Si by the depletion region of a PN junction. The TCR increased as the temperature of rapid thermal anneal (RTA) was increased at the temperature range from $900^{\circ}C$ to $1000^{\circ}C$ for the $p^+$ contact with implantation at dose of $1E16/cm^2$, but sheet resistance of this film was decreased. After the optimization of anneal process condition, the TCR of $1126.7{\pm}30.3$ (ppm/K) was obtained for the $p^-$ resistor-COB package chips contained $p^+$ contact with the implantation of $5E14/cm^2$. This shows the potential of the $^{11}B$-implanted n type Si epi substrate as a resistor for pressure sensor in thermal stable environment applications..

A Study on the mother's attribution and behavioral reaction to behavior problem of child. (아동의 문제행동에 대한 어머니의 귀인과 행동반응의 관계)

  • 이은희
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.2
    • /
    • pp.31-42
    • /
    • 1996
  • The purpose of this study was to examine the mother's perception on the concrete pattern of such behavior problems as noncompliance, jealousy, dependency, hyperactivity and stealing, by analyzing the difference between two cases of her own child and another mother's child relating to her attribution to the behavior problem of the child and the relationship between her attribution and behavioral reaction. This study was carried out by using 515 questionnaires answered by 1000 mothers of children of 7 kindergartens in Ulsan and Taegu, using Melissa Sweitzer's method (1986). The data was subjected to t-test, Pearson's correlation coefficient. T-test was applied to test the difference between two cases of her own child and another mother's child relating to her attribution to the behavior problem of the child and Person's correlation coefficient was estimated to test the relationship between her attribution and behavioral reaction. The result of this study is sumarized as follows : 1. It was shown that the mother's attribution to the behavior problem of the child is less serious when her child showed the behavior problem than when another child dose the problem while her attribution has an affective reaction to the behavior problem of the child. 2. The relationship between the mother's attribution and behavior reaction to the behavior problem of the child appeared variously in accordance with the attribution factor and behavior problem. Then the mother showed more attribution to stability while frequently ignoring the child.

  • PDF

Development of a novel in vitro SPF evaluation method (새로운 in vitro SPF측정법 개발)

  • 오선진;김진준
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.2
    • /
    • pp.57-72
    • /
    • 1995
  • We have recently developed a novel in vitro SPF evaluation method with a high correlation coefficient (r=0.93) to in vivo SPF values(test sunscreen formulas : cress m, foundation). In this method, the in vitro SPF value was determined by the ratio of the time taken to achieve the minimal erythema dose with and without the sunscreens applied. We also reviewed the dilution and thin-layer methods for in vitro SPF evaluation, and investigated the relationship between irradiance(3$\times$10-3 2.5x 10-5W/cm2) and the degree of erythema. The degree of erythema was similar if t he radiation exposure(40mJ/cm2) was kept constant. It was obtained more than 0.90 correlation coefficient when it was compared the results by our new method with those from SPF-290 analyzer (Optometries, U.S.A.).

  • PDF

Comparison of the effects of irradiation on iso-molded, fine grain nuclear graphites: ETU-10, IG-110 and NBG-25

  • Chi, Se-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2359-2366
    • /
    • 2022
  • Selecting graphite grades with superior irradiation characteristics is important task for designers of graphite moderation reactors. To provide reference information and data for graphite selection, the effects of irradiation on three fine-grained, iso-molded nuclear grade graphites, ETU-10, IG-110, and NBG-25, were compared based on irradiation-induced changes in volume, thermal conductivity, dynamic Young's modulus, and coefficient of thermal expansion. Data employed in this study were obtained from reported irradiation test results in the high flux isotope reactor (HFIR)(ORNL) (ETU-10, IG-110) and high flux reactor (HFR)(NRL) (IG-110, NBG-25). Comparisons were made based on the irradiation dose and irradiation temperature. Overall, the three grades showed similar irradiation-induced property change behaviors, which followed the historic data. More or less grade-sensitive behaviors were observed for the changes in volume and thermal conductivity, and, in contrast, grade-insensitive behaviors were observed for dynamic Young's modulus and coefficient of thermal expansion changes. The ETU-10 of the smallest grain size appeared to show a relatively smaller VC to IG-110 and NBG-25. Drastic decrease in the difference in thermal conductivity was observed for ETU-10 and IG-110 after irradiation. The similar irradiation-induced properties changing behaviors observed in this study especially in the DYM and CTE may be attributed to the assumed similar microstructures that evolved from the similar size coke particles and the same forming method.