• Title/Summary/Keyword: Dose Coefficient

Search Result 263, Processing Time 0.037 seconds

Argon and Nitrogen Implantation Effects on the Structural and Optical Properties of Vacuum Evaporated Cadmium Sulphide Thin Films (CdS 박막의 구조적 및 광학적 물성에 미치는 아르곤 및 질소 이온 주입 효과)

  • ;;D. Mangalaraj
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.471-478
    • /
    • 2002
  • Vacuum evaporated cadmium sulphide (CdS) thin films were implanted with $Ar^+$ and $N^+$ for different doses. The properties of the ion implanted CdS thin films have been analysed using XRD, optical transmittance spectra, and Raman scattering studies. Formation of Cd metallic clusters were observed in ion implanted films. The band gap of $Ar^+$ doped films decreased from 2.385 eV of the undoped film to 2.28 eV for the maximum doping. In the case of $N^+$ doped film the band gap decreased from 2.385 to 2.301 eV, whereas the absorption coefficient values increased with the increase of implantation dose. On implantation of both types of ions, the Raman peak position appeared at $299\textrm{cm}^{-1}$ and the FWHM changed with the ion dose.

Parameter Uncertainty and Sensitivity Analysis on a Dose Calculation Model for Terrestrial Food-Chain Pathway (육상식품 섭취경로에 의한 선량계산 모델에서 파라메터의 불확실성 및 민감도 분석)

  • Lee, Chang-Woo;Choi, Yong-Ho;Chun, Ki-Jung;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.67-74
    • /
    • 1991
  • Parameter uncertainty and sensitivity of KFOOD model for calculating the ingestion dose via terrestrial food-chain pathway was analyzed with using Monte-Carlo approach. For the rice ingestion pathway, estimated values from KFOOD code were very conservative. Most sensitive input parameters in model were deposition velocities and soil-to-plant transfer coefficient of radionuclides.

  • PDF

The Effect of Gamma-irradiation on Aqueous Solutions of Triglycine 1. Spectrophotometri Study of Irradiated Triglycine (Triglycine 수용액에 미치는 감마선의 영향 1. 분광광도계에 의한 연구)

  • Leone, Charles A.
    • The Korean Journal of Zoology
    • /
    • v.6 no.2
    • /
    • pp.16-20
    • /
    • 1963
  • Gamma 선을 조사한 triglycine용액을 spectrophotometric trechnique와 ultraviolet absorption을 써서 연구하여 다음 결과를 얻었다. 1. 조사된 striglycine-biuret complex 의 dose-yield curve는 방사선의 간접작용을 보여주는 전형적인 예를 보여주었다. 2. G(CO-NH)는 s1.75였다. 3. Dose-yield data에서 보면 peptide bond reputure는 선량을 증가함에 따라서 감소하는 증가율을 나타내어 분해산물들이 free radical 과 compete함을 알 수있었다. 4. 증가된 triglycine의 molecular extinction coefficient는 5 $\times$1020 ev./ml가지는 비례적증가를 나타내었고 이보다 높은 선량에서는 1.9$\times$1021 ev/ml 에 이르기까지 직선적 감소를 보여 carbonyl compound 의 G치는 0.80이였다.

  • PDF

Effects of Gamma Irradiation on Array Type Fiber Bragg Grating Sensors (배열형 FBG 센서의 감마선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.937-939
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings (FBGs) manufactured by array sensors. The array FBGs were fabricated in a different Bragg wavelength using the same commercial Ge-doped fiber and exposed to gamma-radiation up to a dose of about 100 kGy at the dose rate of 113 Gy/min. It was analyzed radiation effects by measuring the radiation-induced change in the temperature sensitivity coefficient and Bragg wavelength shift after irradiation.

  • PDF

Short-term protein intake increases fractional synthesis rate of muscle protein in the elderly: meta-analysis

  • Gweon, Hyun-Soo;Sung, Hee-Ja;Lee, Dae-Hee
    • Nutrition Research and Practice
    • /
    • v.4 no.5
    • /
    • pp.375-382
    • /
    • 2010
  • The precise effects of protein intake on fractional synthesis rate (FSR) of muscle protein are still under debate. The sample size of these studies was small and the conclusions in young and elderly subjects were inconsistent. To assess the effect of dietary protein intake on the FSR level, we conducted a meta-analysis of controlled protein intake trials. Random-effects models were used to calculate the weighted mean differences (WMDs). Ten studies were included and effects of short-term protein intake were evaluated. In an overall pooled estimate, protein intake significantly increased the FSR (20 trials, 368 participants; WMD: 0.025%/h; 95%CI: 0.019-0.031; P < 0.0001). Meta-regression analysis suggested that the protein dose was positively related to the effect size (regression coefficient = 0.108%/h; 95%CI: 0.035, 0.182; P = 0.009). A subgroup analysis indicated that protein intake significantly increased FSR when the protein dose was ${\leq}$ 0.80 g/kg BW (16 trials, 308 participants; WMD: 0.027%/h; 95%CI: 0.019-0.031; P < 0.0001), but did not affect FSR when the protein dose was > 0.80 g/kg BW (4 trials, 60 participants; WMD: 0.016%/h; 95%CI: 0.004-0.029; P = 0.98). In conclusion, this study is the first integrated results showing that a short-term protein intake is effective at improving the FSR of muscle protein in the healthy elderly as well as young subjects. This beneficial effect seems to be dose-dependent when the dose levels of protein range from 0.08 to 0.80 g/kg BW.

Feasibility of clay-shielding material for low-energy photons (Gamma/X)

  • Tajudin, S.M.;Sabri, A.H.A.;Abdul Aziz, M.Z.;Olukotun, S.F.;Ojo, B.M.;Fasasi, M.K.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1633-1637
    • /
    • 2019
  • While considering the photon attenuation coefficient (${\mu}$) and its related parameters for photons shielding, it is necessary to account for its transmitted and reflected photons energy spectra and dose contribution. Monte Carlo simulation was used to study the efficiency of clay ($1.99g\;cm^{-3}$) as a shielding material below 150 keV photon. Am-241 gamma source and an X-ray of 150 kVp were calculated. The calculated value of ${\mu}$ for Am-241 is higher within 5.61% compared to theoretical value for a single-energy photon. The calculated half-value layer (HVL) is 0.9335 cm, which is lower than that of ordinary concrete for X-ray of 150 kVp. A thickness of 2 cm clay was adequate to attenuate 90% and 85% of the incident photons from Am-241 and X-ray of 150 kVp, respectively. The same thickness of 2 cm could shield the gamma source dose rate of Am-241 (1 MBq) down to $0.0528{\mu}Sv/hr$. For X-ray of 150 kVp, photons below 60 keV were significantly decreased with 2 cm clay and a dose rate reduction by ~80%. The contribution of reflected photons and dose from the clay is negligible for both sources.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

Effects of Powdered Activated Carbon on Anaerobic Digestion (염기성 소화에 대한 활성탄의 영향)

  • 김승현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.102-115
    • /
    • 1990
  • Importance of anaerobic digestion as an energy generating device has been increased as fuel shortage becomes serieous. Several modification methods on the conventional digesters including Powdered Activated Carbon (PAC) addition and two-phase digestion were studied to enhance the gas production. This study investigated the effects of PAC on anaerobic digestion of chicken manure in terms of gas production and sludge stabilization. As a first experiment, an optimum PAC dose for efficient gas production was determined in a batch test. In semi-continuous experiments, an optimum Sludge Retention Time (SRT) at that PAC concentration and an overall substate utilization rate coefficient were investigated. A portion of gas increased by PAC addition was estimated using a substrate utilization rate coefficient of microorganisms attached on PAC. This test was performed in batch experiments using acetic acid as a substrate. The digesters for all experiments were kept 35${\pm}$ 1˚C in a heated water bath. Mixing was performed manually once a day and the produced gas was collected for daily reading. The following conclusions were made for this study. 1. Cptimum PAC concentration was 5% total solids, where gas production rate was increased by 20 percents. 2. Optimum SRT was 7.5 days. 3. Substrate utilization rate coefficient of microorganisms attached on PAC was about twice as much as that of suspended ones.

  • PDF

Pharmaceutical Studies on Chitosan Matrix: Controlled release of aspirin from chitosan device

  • Lee, Chi-Young;Kim, Sung-Ho
    • Archives of Pharmacal Research
    • /
    • v.10 no.2
    • /
    • pp.88-93
    • /
    • 1987
  • Chitosan ($\beta$-D-glucosaminan) is chemically prepared from chitin (N-acetyl-$\beta$- D-glucosaminan) which is an unutilized natural resource. We now report on the suitability of the chitosan matrix for use as vehicles for the controlled release of drugs. Salicylic acid and aspirin were used as model drugs in this study. The permeation of salicylic acid in the chitosan membranes was determined in a glass diffusion cell with two compartments of equal volume. Drug release studies on the devices were conducted in a beaker containing 5% sodium hydroxide solution. Partition coefficient (Kd) value for acetate membrane (472) is much greater than that for fluoro-perchlorate chitosan membrane (282). Higher Kd value for acetate chitosan membrane appears to be inconsisstent with the bulk salicylic acid concentration. The permeability constants of fluoro-perchlorate and acetate chisotan membranes for salicylic acid were 3.139 ${\times}10^{-7}cm^2$ min up to 60 min and that of 30% aspirin in the devices was 4.739${\times}10^{-7}cm^2$sec upto 60 min. As the loading dose of aspirin in a chitosan device increased, water up-take of chitosan device increased, but in case of salicylic acid it decreased. The release rate increased with increase in the molecular volume of the drugs. Thses result suggest that the release mechanism may be controlled mainly by diffusion through pores.

  • PDF

Amorphization of Silicon by 250 keV Electron Irradiation and Hydrogen Annealing

  • Jo Jung-Yol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.23-27
    • /
    • 2005
  • We observed that optical properties of silicon changed under high dose electron irradiation at 250 keV. Our experimental results revealed that the optical transmission through a silicon wafer is significantly increased by electron irradiation. Transmission increase by the change in the absorption coefficient is explained through an analogy with amorphous silicon. Moreover, solar cell open-circuit voltages indicated that defects were generated by electron irradiation, and that the defects responded to annealing. Our results demonstrated that the optical properties of silicon can be controlled by a combination of electron irradiation and hydrogen annealing.