• Title/Summary/Keyword: Doppler study

Search Result 879, Processing Time 0.032 seconds

Study of Doppler Fluid Effects of Carbonated Water in a Bi-directional Flow Phantom Model (양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과 연구)

  • Ji-Hye Kim;Yeong-Cheol Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.83-91
    • /
    • 2024
  • The purpose of this study was to determine the doppler fluid effects of carbonated water (CBW) in a bi-directional flow phantom model. A bi-directional flow phantom model was chosen to realize arterial and venous flow, and the structure of the inner and outer tanks allowed for fluid circulation and also made the size of the phantom small. Carbonated water (CBW), salt fluid (SAF), sugar fluid (SUF), and distilled water (DW) were used as fluids, and ultrasound scans were performed at depths of 1.5 cm and 3.0 cm from the surface of the tank, using B-mode and color Doppler effects. All fluids tested showed color Doppler effects, but CBW had the highest doppler shift and the least variation with depth. In conclusion, we determined that CBW was the most suitable fluid to be used as a doppler fluid and confirmed that the bubbles dissolved in CBW act as doppler scatterers, just like red blood cells inside human blood. Therefore, it is possible that CBW can be used as a blood-mimicking fluid in doppler ultrasound phantoms through further research, and this study will provide basic data.

Interpertation of Doppler Indicies in Neurosonologic Examinations (신경초음파 검사에서 Doppler소견의 판독)

  • Kim, Jei
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 1999
  • The Doppler in neurosonologic examination could be applied to blood flow to determine its movement, the direction of its movement, and how fast it is. Indicies of the Doppler study denoted velocity, direction, and amount of RBC in the examined vessel. Systolic. diastolic, and mean blood flow velocities represent velocity of RBCs in a sample volume. Blood flow direction to the probe means direction of RBC to the probe. Size of amplitude displays toe amount of the RBCs passing the sample volume. Spectral broadening means presence of turbelence. The RBC movements and hemodynamics at the examined vessels can be estimated by analysis of Doppler indicies The formation and meaning of each of neurosonologic Doppler study is described in the present review.

  • PDF

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study (Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구)

  • Kim, Young-Ho;Min, Byung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF

Usefulness of Twinkling Artifacts in Color Doppler Ultrasonography (컬러 도플러 초음파에서 Twinkling artifacts의 유용성)

  • Sim, Hyun-Sun;Kwon, Kyung-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.291-298
    • /
    • 2016
  • The aim of the study was to investigate the diagnostic value of the color Doppler twinkling artifact in disease of urinary system. The intensity of twinkling artifact(TA) with color Doppler was classified into 3 levels, 0(non-TA) to 3(distinct TA). In the in vitro study, acorn jelly with various materials on top was examined using color Doppler at B-mode sonography in a water bath for TA. 31 patients with diagnosis of urinary calculi(renal stones 16, urinary stones 15) based on B-mode sonography were studied in vivo for TA. The materials with rough surfaces such as salt, screw and cubics at B-mode sonography with color Doppler contributed to causing TA. At B-mode sonography without color Doppler 37% of renal stones and 60% of ureter stones were detected. but at B-mode sonography with color Doppler TA was demonstrated for all cases. Superficial roughness of materials affected occurrence of TA at B-mode sonography with color Doppler. Therefore, TA at B-mode sonography without color Doppler could play a role in confident diagnosis of the disease of urinary system.

Quantitative Doppler echocardiography during Dobutamine stress test in canine mitral regurgitant model

  • Choi, Hojung;Won, Sungjun;Lee, Kichang;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.317-322
    • /
    • 2004
  • This study was performed to evaluate echocardiographic parameters in dogs with experimental mitral regurgitation subjected to dobutamine stress testing. In 8 beagle dogs, a 4-prong grasping forceps was inserted into the left ventricle through the carotid artery with fluoroscopic guidance. The disruption of chordae or mitral valve leaflet was performed. Echocardiographic protocols included quantitative Doppler echocardiography and M-mode measurement for evaluating left ventricle function. After all measurement was obtained at rest, dobutamine was infused incrementally. In stress testing, all measurement also was performed at rest as the same method. In stress Doppler echocardiography, regurgitant fraction and aortic stroke volume was increased significantly (P<0.001). Effective regurgitant orifice and regurgitant volume was not changed. In M-mode examination, fractional shortening was increased significantly at stress test (P<0.001). From the results obtained in this study, it could be suggested that dobutamine stress echocardiography increase left ventricle performance in non-functional mitral regurgitation and quantitative Doppler echocardiography is non-invasive, accurate method in valvular regurgitation.

A Study on the Robust Real-Time Signal Processor of a Laser Doppler Vibrometer for Noises (노이즈에 둔감한 레이저 진동계측기용 실시간 신호처리 장치에 관한 연구)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.61-67
    • /
    • 1999
  • A laser Doppler vibrometer based on the laser heterodyne interferometry is employed to measure the vibration velocity of vibrating objects. In this paper, we propose a real time analog signal processor of a laser Doppler vibrometer to reduce the degradation of Doppler signals mainly caused by environmental noises. In the proposed real time signal processor of an laser Doppler vibrometer, a pre-processor and a logical motion direction detector are designed to reduce the detection errors of the object motion direction. Also, a noise detection and rejection circuit is designed to reject the unfiltered noises.

  • PDF

A study of 10.5 GHz band Doppler radar for non-contact type hydrometer (비접촉식 유속계를 위한 10.5 GHz 대역 도플러 레이더에 대한 연구)

  • Kim, Jin-Su;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.139-144
    • /
    • 2009
  • A Doppler radar is a radar using the doppler effect of the returned echoes from targets to measure their radial velocity. To be more specific the microwave signal sent by the radar antenna's directional beam is reflected toward the radar and compared in frequency, up or down from the original signal, allowing for the direct and highly accurate measurement of target velocity component in the direction of the beam. In this paper, we designed the doppler radar composed of 10.5 GHz band DROs(Dielectric Resonator Oscillator), $90^{\circ}C$ branch line coupler, single balanced mixer and $4{\times}4$ array antenna of high gain, high directivity, for non-contact type hydrometer. Fabricated Doppler radar can detect slow moving objects.

  • PDF

A Study on Effects of Antenna Diversity in Doppler Spread Environments (도플러 확산 환경에서의 안테나 다이버시티 효과에 관한 연구)

  • Lee Jong-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.510-515
    • /
    • 2005
  • Doppler spread can occur due to the relative movement of transmitter and receiver. The Doppler frequency shift varies as the relative location and the velocity of transceivers change. This Doppler spread may seriously degrade the performance of OFDM system which is considered to be very efficient for multimedia wireless communication. Therefore, applying the method of receiver diversity, we analyze the degree of BER improvement in Doppler spread environments to investigate the effectiveness of the chosen methods according to various wireless channels.

A Study on the Pulsed Doppler System using Quadrature-Sampling Method in R.F. Range (RF (Radio Frequency) 영역에서의 Quadrature sampling을 이용한 펄스 도플러 장치의 개발에 관한 연구)

  • Kim, Jae-Kyoung;Jeong, Taek-Seob;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.297-300
    • /
    • 1988
  • The ultrasound Doppler effect is used for measuring the velocity of the bloodflow in an artry. Because of the range information, the pulsed doppler system is most commonly used. In this paper, we propose a new pulsed doppler system which uses a quadrature sampling method in R.F. range in order to detect the bloodflow direction and to simplify the compexity of hardware. The pulsed doppler system using quadrature sampling method in R.F. range eliminates In-phase, Quadrature phase channel balancing problem at demodulator. In addition, the improved pulsed Doppler system shows the possibility of serial processing.

  • PDF