• Title/Summary/Keyword: Doppler flow meter

Search Result 40, Processing Time 0.03 seconds

Flood Runoff Measurements using Surface Image Velocimetry (표면영상유속계(SIV)를 이용한 홍수유출량 측정)

  • Kim, Yong-Seok;Yang, Sung-Kee;Yu, Kwon-Kyu;Kim, Dong-Su
    • Journal of Environmental Science International
    • /
    • v.22 no.5
    • /
    • pp.581-589
    • /
    • 2013
  • Surface Image Velocimetry(SIV) is an instrument to measure water surface velocity by using image processing techniques. Since SIV is a non-contact type measurement method, it is very effective and useful to measure water surface velocity for steep mountainous streams, such as streams in Jeju island. In the present study, a surface imaging velocimetry system was used to calculate the flow rate for flood event due to a typhoon. At the same time, two types of electromagnetic surface velocimetries (electromagnetic surface current meter and Kalesto) were used to observe flow velocities and compare the accuracies of each instrument. The comparison showed that for velocity distributions root mean square error(RMSE) was 0.33 and R-squared was 0.72. For discharge measurements, root mean square error(RMSE) reached 6.04 and R-squared did 0.92. It means that surface image velocimetry could be used as an alternative method for electromagnetic surface velocimetries in measuring flood discharge.

Experimental and Computational Studies on Flow Behavior Around Counter Rotating Blades in a Double-Spindle Deck

  • Chon, Woo-Chong;Amano, Ryoichi S.
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1401-1417
    • /
    • 2004
  • Experimental and computational studies were performed to determine the effects of different blade designs on a flow pattern inside a double-spindle counter rotating mower deck. In the experimental study, two different blade models were tested by measuring air velocities using a forward-scatter LDV system. The velocity measurements were taken at several different azimuth and axial sections inside the deck. The measured velocity distributions clarified the air flow pattern caused by the rotating blades and demonstrated the effects of deck and blade designs. A high-speed video camera and a sound level meter were used for flow visualization and noise level measurement. In the computational works, two-dimensional blade shapes at several arbitrary radial sections have been selected for flow computations around the blade model. For three-dimensional computation applied a non-inertia coordinate system, a flow field around the entire three-dimensional blade shape is used to evaluate flow patterns in order to take radial flow interactions into account. The computational results were compared with the experimental results.

Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects (간섭전류자극이 말초 혈류속도에 미치는 영향)

  • Park Jang-Sung;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

  • PDF

Characteristics of Tide-induced Flow and its Effect on Pollutant Patterns Near the Ocean Outfall of Wastewater Treatment Plants in Jeju Island in Late Spring (제주도 하수처리장 해양방류구 인근해역의 늦은 봄철 조류 특성과 조석잔차류에 의한 오염물질의 분포 특성)

  • KIM, JUN-TECK;HONG, JI-SEOK;MOON, JAE-HONG;KIM, SANG-HYUN;KIM, TAE-HOON;KIM, SOO-KANG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.2
    • /
    • pp.63-81
    • /
    • 2021
  • In this study, we investigated the tide-induced flow patterns near the ocean outfall of the Jeju and Bomok Wastewater Treatment Plants (WTP) in Jeju Island by using measurements of Acoustic Doppler Current Meter (ADCP) and a numerical experiment with inserting passive tracer into a regional ocean model. In late spring of 2018, the ADCP measurements showed that tidal currents dominate the flow patterns as compared to the non-tidal components in the outfall regions. According to harmonic analysis, the dominant type of tides is mixed of diurnal and semi-diurnal but predominantly semidiurnal, showing stronger oscillations in the Jeju WTP than those in the Bomok WTP. The tidal currents oscillate parallel to the isobath in both regions, but the rotating direction is different each other: an anti-clockwise direction in the Jeju WTP and a clockwise in the Bomok WTP. Of particular interest is the finding that the residual current mainly flows toward the coastline across the isobath, especially at the outfall of the Bomok WTP. Our model successfully captures the features of tidal currents observed near the outfall in both regions and indicates possibly high persistent pollutant accumulation along the coasts of Bomok.

Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP (다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석)

  • Ji, Ju-Yeon;Park, Seung-Yong;Lee, Gwang-Woo;Park, Gyeong-Min;Hwang, Soon-Hong;Kim, Dong-Ho;Lee, Young-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

The Change of Blood Flow Velocity of Radial Artery after Linear Polarized Infrared Light Radiation near the Stellate Ganglion: Comparing with the Stellate Ganglion Block (성상신경절 부위의 직선편광 근적외선 조사 후 요골동맥에서의 혈류속도의 변화: 성상신경절 차단술과의 비교)

  • Han, Soung-Moon;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.37-40
    • /
    • 2001
  • Background: It had been reported by authors that linear polarized infrared light radiation (Superizer: SL) near the stellate ganglion had a similar effect on the change of skin temperature of hand compared with the stellate ganglion block (SGB). We hypothesized that this was due to dilatation of vessels and an increased blood flow. The aim of this study was to measure the velocity of blood flow in peripheral vessels after linear polarized infrared light radiation near the stellate ganglion and to compare the effect of SL with that of SGB using local anesthetics. Methods: Forty patients whose clinical criteria were matched for the symptoms of SGB were selected for study. We radiated the stellate ganglion by linear polarized infrared light radiation and measured the blood flow of radial artery using Ultrasound Doppler blood flow meter before and after 10, 20 and 30 minutes post-radiation. After 3 days, SGB was performed using 8 ml of 1% mepivacaine to the same patient, and the radial artery blood flow was measured in the same manner. Results: The blood flow velocity was increased by 40% and 27% at 10 min and 20 min after SL and by 42% and 41% at 10 min and 20 min after SGB. However, there was no statistically significant difference in blood flow velocity between SGL and SGB. Conclusions: We could conclude that linear polarized radiation is a clinically simple and useful noninvasive therapeutic tool in clinical area.

  • PDF

Changes in blood flow at the mandibular angle and Horner syndrome in a rat model of superior cervical ganglion block

  • Kubota, Kazutoshi;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2018
  • Background: A stellate ganglion block (SGB) causes increased blood flow in the maxillofacial region, exhibiting the potential for regenerative effects in damaged tissue. The focus of this study was to understand the efficacy of SGB for regenerative effects against nerve damage. A rat model of the superior cervical ganglion block (SCGB) was created instead of SGB, and facial blood flow, as well as sympathetic nervous system function, were measured. Methods: A vertical incision was made on the left side of the neck of a Wistar rat, and a 5-mm resection of the superior cervical ganglion was performed at the back of the bifurcation of the internal and external branches of the left common carotid artery. Blood flow in the skin at the mandibular angle and mean facial temperature were measured using a laser-Doppler blood flow meter and a thermographic camera, respectively, over a 5-week period after the block. In addition, the degree of ptosis and miosis were assessed over a period of 6 months. Results: The SCGB rat showed significantly higher blood flow at the mandibular angle on the block side (P < 0.05) for 3 weeks, and significantly higher skin temperature (P < 0.05) for 1 week after the block. In the SCGB rat, ptosis and miosis occurred immediately after the block, and persisted even 6 months later. Conclusions: SCGB in rats can cause an increase in the blood flow that persists over 3 weeks.

Evaluation of Thrombolytic Effect of Streptokinase-Dextran Conjugate in a Rat Model of Arterial Thrombosis (흰쥐의 대퇴동맥 혈전 모델에서의 스트렙토키나제-덱스트란 포합체의 혈전용해효과의 평가)

  • Kim, Yang-Woo;Kim, Dong-Chool
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.3
    • /
    • pp.211-216
    • /
    • 1999
  • To evaluate the thrombolytic activity of streptokinase-dextran conjugate, a rat model of arterial thrombosis was used. Briefly, the femoral artery was exposed and a filter paper saturated with 70% $FeCl_3$ solution was placed around the femoral artery in order to stop the blood flow. Six minutes after the stop of the blood flow in the femoral artery, streptokinase $(10000{\sim}30000\;units\;per\;rat)$ or streptokinase-dextran conjugate $(5000{\sim}17000\;units\;per\;rat)$ was administered by i.v. bolus injection through the femoral vein. Then the blood flow in the femoral artery was monitored using a Doppler laser flow meter. The i.v. bolus administration of streptokinase could not restore the blood flow in the femoral artery in the dose range of $10000{\sim}30000$ units per rat. The i.v. bolus administration of streptokinase-dextran conjugate could restore the blood flow in the femoral artery in the dose range of $5000{\sim}17000$ units per rat. A good correlation between the dose of streptokinase-dextran conjugate and the total thrombolytic effect was observed. In addition, the lag time between the injection of streptokinase-dextran conjugate and the restoring of the blood flow was decreased as the i.v. dose of streptokinase dextran conjugate increased. These results show the superior beneficial effect of streptokinase-dextran conjugate compared with the unconjugated streptokinase with respect to the elongation of thrombolytic activity, the administration method (single injection versus continuous infusion), and the reduced dose necessary for a equivalent thrombolytic effect.

  • PDF

The Effects of Local Anesthetic Agent and Epinephrine on Blood Flow of Femoral Artery in Rabbit (가토에서 국소 마취제와 Epinephrine이 대퇴동맥이 혈류에 미치는 영향)

  • Oh, Soo-Won;Koo, Gil-Hoi;Lee, Choon-Hi
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.46-56
    • /
    • 1996
  • Many surgeons and anesthesiologists prefer using vasoconstrictor mixed with local anesthetic agent to reduce the incidence of side effects and prolong the duration of analgesia because most local anesthetic agents, except cocaine, were believed to possess vasodilating effect. However, some investigators recently reported vasoconstricting effect of local anesthetic agents. There is still controversy on the vasoactive effect of local anesthetic agents. So this study is aimed to clarify the vasoactive effect of local anesthetics in the animal model resembling clinical settings. Rabbits were anesthesized with ketamine and haloghane, and respirations were controlled with Harvard animal ventilator. Lidocaine (0.5%, 1.0%, 1.5%) and bupivacaine (0.125%, 0.25% and 0.5%) with or without 1:100,000 epinephrine were subdermaly injected on the femoral bupivacaine of the femoral artery were measured with Doppler flow meter in vivo. The mean arterial pressure, pulse rate, arterial blood gases, pH and level of serum electrolytes were measured at every 2 minute interval for 30 minutes. Results were as follows: 1) There was no significant vasoconstriction with 0.5% lidocaine and 0.125% bupivacaine. 2) Statistically significant (p<0.05) vasodilations were observed with lidocaine (1.0~2.0%) and bupivacaine (0.25~0.5%). 3) There were no changes on the duration of vasodilation induced by local anesthetic agents of various concentrations. 4) Onset of vasodilation induced by local anesthetic agents of high concentration were faster than that of lower concentrations. 5) In the mixed injection group of epinephrine and local anesthetic agent, the vasoconstriction induced by epinephrine was completely reversed by local anesthetics, approximately 5 minutes later. In conclusion, local anesthetic agents at dose exceeding 1.0% lidocaine and 0.25% bupivacaine increase local blood flow significantly in animal study in vivo which is applicable in human clinical settings. The increase blood flow may be due to dilatation of blood vessel. Further study on the analysis of association between amount of absorbed local anesthetics in blood vessels and dilatation of blood vessels is needed.

  • PDF

Application of microwave water surface current meter for measuring agricultural water intake (농업용수 사용량 계측을 위한 전자파 표면유속계의 적용)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1071-1079
    • /
    • 2020
  • For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.