• Title/Summary/Keyword: Doppler flow meter

Search Result 40, Processing Time 0.019 seconds

Verification and Application of Velocity Measurement Using Price Meter and ADCP (회전식유속계와 ADCP를 이용한 유속측정의 검증 및 적용)

  • Kim, Eung-Seok;Choi, Hyun-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.101-106
    • /
    • 2009
  • Although ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1990's, in-situ behavior performance of ADCP at stream gauging stations has not been evaluated in Korea. The purpose of this study is for verification and application of velocity measurements using a price meter and ADCP. The verification of measured velocities was carried out in a laboratory open-channel. The differences between the two velocity values measured by a pirce meter and ADCP are within 2.1%, which means that ADCP can be used at stream gauging stations. After verification, ADCP was applied to the Maekok stream selected as a test site for application. for application. The test application was performed by comparison of velocity results measured by ADCP and a price meter. Results show that the velocity values obtained by using ADCP coincide well with those by using conventional devices with the average measurement discrepancy of 10.5%.

Vascular Anatomy of Peroneal Perforator Flap (비골 동맥 천공지 피판의 혈관 해부학)

  • Chung, Duke Whan;Han, Chung Soo;Hwang, Joon Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.36-42
    • /
    • 2004
  • Materials and Methods: We studied 50 cases of peroneal perforating branch about branching pattern, course, length of vascular pedicle, and perforating level of the perforating cutaneous branches from Oct. 1985 to November 2003 by doppler flow meter and intraoperative findings. Results: 1) The perforating cutaneous branches were classified into four types, the Straight Branch (27cases), the Proximal Oblique Branch (11cases), the Branch from Muscular Artery (10cases), the Distal Oblique Branch(2 cases) respectively. The most common patten was Straight Branch, that was 54%. 2) There were 3 pathways of these branches, the most common one passed between the Soleus and Peroneus muscles(34 cases, 68%) 3) The length of vascular pedicle in Buoy Flap was variable from from 3 cm to 15 cm, but 32 cases(64%) were distributed between 5 cm and 6 cm. 4) The perforating level of branches were 5.9 cm in average from fibular neck to subcutaneous perforator artery 5) Peroneal Buoy Flap in possible to reconstruct both seperated bone and skin defect in some distance by One-Stage Operation and we can harvest maximal $8{\times}16cm$ sized flap in one perforating artery. If we include more two perforating artery, we get more wide flap which can cover large defect.

  • PDF

An Experimental Study on the Characteristics of the In-cylinder Eccentricity Swirl Flow with Intake Port Shapes in a 4 Valve Diesel Engine (4밸브 디젤기관의 흡기포트 형상에 따른 실린더 내 편심 선회유동 특성에 관한 실험적 연구)

  • 이지근;김덕진;강신재;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.59-72
    • /
    • 1998
  • This experimental study was carried out to investigate the characteristics of the in-cylinder eccentricity swirl flow generated by a 4 valve cylinder head with a tangential and a helical intake port. the measurements of the in-cylinder velocity field have been made by a two-channel LDA system. The mean flow coefficient(Cf(meam)), swirl ratio(Rs) and mass flowrate with valve eccentricity ratios and an intake port partition between the two intake ports were measured in the steady flow test fig using the ISM(impulse swirl meter). The experimental results indicated that the mass flowrate through the tangential intake port was 19% and 7.7% more than that of the helical intake port in case of with and without intake port partition respectively. There was a tendency to be a single rotation flow in swirl flow fields formed by a 4 valve cylinder head because of the interaction between the two intake ports. As the intake port partition was not set between flow coefficient(Cf(mean)) was 7.35%.

Comparison of Peripheral Blood Flow in Post-Stroke Hemiparetic Patients and Normal Person with Doppler Ultrasonography (도플러 초음파 기기를 이용한 편측 부전마비성 뇌졸중 환자와 정상인의 말초 혈류 비교 연구)

  • Han, Deok-Jin;Bang, Chang-Ho;Kim, Sergey;Bae, Young-Min;Shin, Sae-Ron;Yang, Chung-Yong;Lee, In
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1491-1496
    • /
    • 2009
  • Stroke is usually associated with the cerebral blood flow of the central nervous system. However, studies concerning the effects of neurologic sysmptoms induced from stroke on the peripheral blood flow has not taken place sufficiently. To ascertain the feasibility of a blood flow meter adopting to use doppler ultrasonogrphy, under the prospect that hemiparesis induced from stroke may have effect on the peripheral blood flow, the peripheral blood flow velocity was observed. The control group made up of healthy people without any factors capable of effecting the peripheral blood flow velocity, and patient group which consist of hemiparetic people induced from stroke, were recruited. Volumes of recruitment are 21 persons in the patient group, and 29 persons in the control group, but the final numbers of people are 17 and 21 respectively because of the inconsistancy in the method of the test. The non-invasive method of Doppler effect of Ultrasound was used to measure the blood flow velocity. The blood flow velocity in the peripheral part of left and right fourth fingers:dorsal branches of proper palmar digital artery to dorsum of distal phalanges, was measured in the control group and patient group through Doppler Ultrasound. In comparison of the control group and the patient group, the systolic blood flow velocity from the peripheral part of the upper extremity was lower in the patient group than that of the control group. According to such results, it is concluded that hemiparesis induces the reduction of the peripheral blood flow velocity in the systolic phase.

The Predictive Value of Laser Doppler for Flap Survival (재관류손상을 받은 가토의 이개 피판에서 레이저도플러에 의한 피판 생존의 예측)

  • Kim, Seok Kwun;Park, Jung Min;Baek, Chang Yoon;Jung, Gi Hwan;Lee, Keun Cheol;Jung, Jin Suk;Park, Ju In;Park, Byung Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.503-510
    • /
    • 2005
  • If we could predict the necrosis of the flap caused by reperfusion injury, we can minimize the necrosis of the flap by taking appropriate action before necrosis begins. In this study, we examined whether we can predict the survival of flap under reperfusion injury or not, by measuring laser doppler flow meter values. We divided the group into the control and experimental groups corresponding to 6, 8, 9, 10, and 12hours after reperfusion(hours after ligation of auricular central artery). In each group, we examined necrotic change, perfusion unit (PU), serum superoxide dismutase (SOD), glutathione peroxidase, angiography and pathologic findings. No necrosis was observed in the 6 and 8 hours group but 8, 18, 20 hours after ligation, necrosis was observed, Also in each of 9, 10 and 12 hours group (each group consisted of 20 flaps), necrosis were noted. According to the above data, the critical time of necrosis in the auricular skin flap model lies between about 8 to 9 hours. Comparing the PU between the necrosis and non-necrosis groups, the former group showed a mean 39.57 PU increase after 60 min of reperfusion, and the latter group showed a mean increase of 21.21 PU. We can conclude that better flow can dilute oxygen free radical into systemic circulation, and this means less injuries are caused on vessels. Our study implies that if blood flow increase is less than 30 PU, intensive care is needed to save the flap. Additionally, we found significant decrease of serum SOD and glutathione peroxidase in the necrotic group. Therefore, monitoring these serum markers will be helpful in predicting reperfusion injury and supplementing these enzymes could be helpful to save the flap. The laser doppler flow meter is thought to be helpful in clinical circumstances for evaluating the circulation of the flap after the operation. However, more accumulation of clinical studies should be necessary establishing useful clinical data.

Optimal Gas-Flow Conditions for Stabilization of Lean-Burn Combustion (희박연소 안정화를 위한 가스유동장 조건에 관한 연구)

  • 이기형;이창식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.763-770
    • /
    • 1995
  • Gas flow characteristics within the cylinder is important factors in impoving lean combustion stability. This paper shows the effects of various flow fields generated by a swirl control valve(SCV) on combustion process in a 4-valve spark ignition engine. An impulse swirl/tumble meter was used to elucidation the steady-state flow characteristics, and a rotating grating type LDV was developed to measure the mean velocity and tunbulence intensity in relation to the crank angle. These methodologies were applied to clarify the correlation between gas flow characteristics and combustion stability at a lean air fuel ratio. An analysis of the correlation revealed the gas flow conditions required to optimize a lean-burn system.

Development of flow measurement method using drones in flood season (II) - application of surface velocity doppler radar (드론을 이용한 홍수기 유량측정방법 개발(II) - 전자파표면유속계 적용)

  • Lee, Tae Hee;Kang, Jong Wan;Lee, Ki Sung;Lee, Sin Jae
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.11
    • /
    • pp.903-913
    • /
    • 2021
  • In the flood season, the measurement of the river discharge has many restrictions due to reasons such as budget, manpower, safety, convenience in measurement and so on. In particular, when heavy rain events occur due to typhoons, etc., it is difficult to measure the amount of flood due to the above problems. In order to improve this problem, in this study, a method was developed that can measure the river discharge in a flood season simply and safely in a short time with minimal manpower by combining the functions of a drone and a surface velocity doppler radar. To overcome the mechanical limitations of drones caused by weather issues such as wind and rainfall derived from the measurement of the river discharge using the conventional drone, we developed a drone with P56 grade dustproof and waterproof performance, stable flight capability at a wind speed of up to 36 km/h, and a payload weight of up to 10 kg. Further, to eliminate vibration which is the most important constraint factor in the measurement with a surface velocity doppler radar, a damper plate was developed as a device that combines a drone and a surface velocity Doppler radar. The velocity meter DSVM (Dron and Surface Veloctity Meter using doppler radar) that combines the flight equipment with the velocity meter was produced. The error of ±3.5% occurred as a result of measuring the river discharge using DSVM at the point of Geumsan-gun (Hwangpunggyo) located at Bonghwang stream (the first tributary stream of the Geum River). In addition, when calculating the mean velocity from the measured surface velocity, the measurement was performed using ADCP simultaneously to improve accuracy, and the mean velocity conversion factor (0.92) was calculated by comparing the mean velocity. In this study, the discharge measured by combining a drone and a surface velocity meter was compared with the discharge measured using ADCP and floats, so that the application and utility of DSVM was confirmed.

Analysis of Cylinder Swirl Flow and Lean Combustion Characteristics of 3rd Generation LPLI(Liquid Phase LPG Injection) Engine (제3세대 LPLI 엔진 연소실내 스월유동 및 희박연소 특성 해석)

  • Kang, Kern-Yong;Lee, Jin-Wook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • The intake swirl motion, as one of dominant effects for an engine combustion. is very effective for turbulence enhancement during the compression process in the cylinder of 2-valve engine. Because the combustion flame speed is determined by the turbulence that is mainly generated from the mean flow of the charge air motion in intake port system. This paper describes the experimental results of swirl flow and combustion characteristics by using the oil spot method and back-scattering Laser Doppler velocimeter (LDV) in 2-valve single cylinder transparent LPG engine using the liquid phase LPG injection. For this. various intake port configurations were developed by using the flow box system and swirl ratios for different intake port configurations were determined by impulse swirl meter in a steady flow rig test. And the effects of intake swirl ratio on combustion characteristics in an LPG engine were analyzed with some analysis parameters that is swirl ratio. mean flow coefficient, swirl mean velocity fuel conversion efficiency. combustion duration and cyclic variations of indicated mean effective pressure(IMEP). As these research results, we found that the intake port configuration with swirl ratio of 2.0 that has a reasonable lean combustion stability is very suitable to an $11{\ell}$ heavy-duty LPG engine with liquid phase fuel injection system. It also has a better mean flow coefficient of 0.34 to develope a stable flame kernel and to produce high performance. This research expects to clarify major factor that effects on the design of intake port efficiently with the optimized swirl ratio for the heavy duty LPG engine.

Changes in Cerebral Blood flow Following Fermented Garlic Extract Solution with High Content of Nitrite (흰쥐에서 고용량 아질산이온 함유 마늘 발효농축액에 의한 뇌혈류 변화)

  • Yu, Hyeok;Rong, Zhang Xiao;Koo, Ho;Chun, Hyun Soo;Yoo, Su Jin;Kim, Min Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.34 no.6
    • /
    • pp.326-333
    • /
    • 2020
  • Nitrate-nitrite-nitric oxide (NO) pathway is a major alternative source of NO and is essential for NO - dependent physiological functions in body. Food supplements having nitrate/nitrite can improve metabolic syndromes including hypertension through antioxidant activity or vasodilation. The purpose of this study was to observe the effects of fermented garlic (F. garlic) having high concentration of NO2- on changes in blood flow and nitric oxide synthesis in the cerebral cortex of rodents. The generation of nitric oxide detected by a chemi-luminescence detector was higher in F. Garlic compared with NaNO2 solution under artificial gastric juice with pH 2.0. Ether F. garlic or NaNO2 diluted with artificial cerebrospinal fluid was directly applied into around the needle probe of laser Doppler flow meter that was located on epidural surface of the cortex. Direct application of F. garlic resulted in increase of cerebral blood flow detected by a laser Doppler flow meter with a dose-dependent manner. Compared with NaNO2 solution, F. garlic produced changes in cerebral blood flow at lower concentration of NO2-. Pretreatment of methylene blue, a guanylyl cyclase inhibitor prevented upregulation of cerebral blood flow by the treatment of F. garlic. In addition, the application of F. garlic with 250, 500ppm of NO2- caused significantly the production of NO in the cortical tissue but NaNO2 solution with 500ppm of NO2- did not. In summary, these results suggested that F. garlic with high content of NO2- induce increase in cerebral blood flow through nitric oxide-dependent signal pathway.

The use of laser Doppler blood flow to assess the effect of acute administration of vitamin D on micro vascular endothelial function in people with diabetes

  • Petrofsky, Jerrold;Alshammari, Faris;Khowailed, Iman Akef;Lodha, Riya;Deshpande, Pooja;Rajaram, Praveen;Gaikwad, Mahendra;Vadera, Vidhi
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • Objective: To assess the effect of vitamin D administration on the skin blood flow response to occlusion and heat. Design: Cross-sectional study. Methods: Twenty age matched subjects; 10 who had diabetes and 10 who were controls were administered 4,000 IU of vitamin D3 for 3 weeks at breakfast. The function of the endothelial cells was evaluated in 2 ways; first, the response to 4 minutes of vascular occlusion of the skin was measured with a laser Doppler flow meter. Second, the skin blood flow response to local heat at 42 degrees C for 6 minutes was examined. Results: The results of the experiments showed that the blood flow response to heat was reduced after 3 weeks administration of vitamin D in the subjects with diabetes and in the control subjects (p<0.05). The response to occlusion was not significantly different within each group before and after vitamin D administration, but the group with diabetes had a significantly lower blood flow response to occlusion than did the controls (p<0.05). Conclusions: Acute doses of vitamin D may impair nitric oxide production and reduce blood flow to tissue during stressors in people with diabetes.