• 제목/요약/키워드: Doppler center

검색결과 272건 처리시간 0.027초

수중운동체 복합항법 성능 향상을 위한 DVL/RPM 기반의 속도 필터 설계 (DVL-RPM based Velocity Filter Design for a Performance Improvement Underwater Integrated Navigation System)

  • 유태석;윤선일
    • 제어로봇시스템학회논문지
    • /
    • 제19권9호
    • /
    • pp.774-781
    • /
    • 2013
  • The purpose of this paper is to design a DVL-RPM based VKF (Velocity Kalman Filter) design for a performance improvement underwater integrated navigation system. The proposed approach relies on a VKF, augmented by a altitude from Echo-sounder based switching architecture to yield robust performance, even when DVL (Doppler Velocity Log) exceeds the measurement range and the measured value is unable to be valid. The proposed approach relies on two parts: 1) Indirect feedback navigation Kalman filter design, 2) VKF design. To evaluate proposed method, we compare the results of the VKF aided navigation system with simulation result from a PINS (Pure Inertial Navigation System) and conventional INS-DVL method. Simulations illustrate the effectiveness of the underwater navigation system assisted by the additional DVL-RPM based VKF in underwater environment.

속도필터 적용 수중운동체 복합항법 알고리즘 개발 (Development of Integrated Navigation Algorithm for Underwater Vehicle using Velocity Filter)

  • 유태석;정규필;윤선일
    • 한국해양공학회지
    • /
    • 제27권2호
    • /
    • pp.93-99
    • /
    • 2013
  • This paper describes a robust algorithm for an integrated underwater navigation system based on VKF (velocity Kalman filter). The proposed approach relies on a VKF, augmented by the altitude from an echo-sounder-based switching architecture to yield robust performance, even when DVL (Doppler velocity log) exceeds the measurement range and the measured value cannot be valid. The proposed approach relies on three parts: 1) PINS (pure inertial navigation system), 2) VKF design, and 3) VKF-aided integrated navigation filter design. To evaluate the proposed method, we compare the results of the VKF-aided navigation system with the simulation result from a PINS and conventional INS-DVL method.

Effects of Cardiotonic Pills® on Cerebrovascular CO2 Reactivity and Erythrocyte Deformability in Normal Subjects: A Pilot Study

  • Sang-Kwan Moon;Han-Gyul Lee;Seungwon Kwon;Seung-Yeon Cho;Seong-Uk Park;Woo-Sang Jung;Jung-Mi Park;Chang-Nam Ko;Ki-Ho Cho
    • 대한한의학회지
    • /
    • 제44권4호
    • /
    • pp.87-103
    • /
    • 2023
  • Backgrounds and objectives: Cardiotonic Pills® (CP) are used for vascular diseases such as coronary diseases, atherosclerosis, and cerebral infarction. This study aimed to determine the transient effects of CP on cerebrovascular CO2 reactivity (CVR) and erythrocyte deformability in normal subjects. Methods: This study had a crossover design and included 10 participants who were randomly allocated to 2 groups. The experimental group was given CP with water, while the control group was given only water. CVR was measured by hyperventilation-induced CVR of the middle cerebral artery (MCA) using transcranial Doppler (TCD). Erythrocyte deformability was measured using a Rheoscan-D microfluidic ektacytometer. All measurements were performed prior to and 1, 2, and 3 hours after CP or water administration. Blood pressure and heart rate were also measured before and after administration. Results: CP significantly improved CVR 3 hours after administration in the experimental group compared to the control group (p = 0.042). The corrected blood flow velocity at partial pressure of end-tidal carbon dioxide (PETCO2) = 40mmHg (CV40) was also significantly improved 2 and 3 hours after administration in the CP group compared to the control group (p = 0.036 and p = 0.021, respectively). CP significantly improved erythrocyte deformability 3 hours after administration in the experimental group compared to the control group (p = 0.027). Mean heart rate and mean blood pressure showed no change. Conclusions: This study demonstrated that CP increases CVR and erythrocyte deformability. These results suggested that CP improves cerebral microcirculation which provide evidence for the future use of CP for prevention of ischemic stroke and neurodegenerative diseases.

The Effect of Extracellular Glutamate Release on Repetitive Transient Ischemic Injury in Global Ischemia Model

  • Lee, Gi-Ja;Choi, Seok-Keun;Eo, Yun-Hye;Kang, Sung-Wook;Choi, Sam-Jin;Park, Jeong-Hoon;Lim, Ji-Eun;Hong, Kyung-Won;Jin, Hyun-Seok;Oh, Berm-Seok;Park, Hun-Kuk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제13권1호
    • /
    • pp.23-26
    • /
    • 2009
  • During operations, neurosurgeons usually perform multiple temporary occlusions of parental artery, possibly resulting in the neuronal damage. It is generally thought that neuronal damage by cerebral ischemia is associated with extracellular concentrations of the excitatory amino acids. In this study, we measured the dynamics of extracellular glutamate release in 11 vessel occlusion(VO) model to compare between single occlusion and repeated transient occlusions within short interval. Changes in cerebral blood flow were monitored by laser-Doppler flowmetry simultaneously with cortical glutamate level measured by amperometric biosensor. From real time monitoring of glutamate release in 11 VO model, the change of extracellular glutamate level in repeated transient occlusion group was smaller than that of single occlusion group, and the onset time of glutamate release in the second ischemic episode of repeated occlusion group was delayed compared to the first ischemic episode which was similar to that of single 10 min ischemic episode. These results suggested that repeated transient occlusion induces less glutamate release from neuronal cell than single occlusion, and the delayed onset time of glutamate release is attributed to endogeneous protective mechanism of ischemic tolerance.

FMCW 레이다 기반 휴먼 모션 인지용 레이다 영상 추출 기법 (Radar Image Extraction Scheme for FMCW Radar-Based Human Motion Indication)

  • 현유진;진영석;전형철
    • 한국전자파학회논문지
    • /
    • 제29권6호
    • /
    • pp.411-414
    • /
    • 2018
  • 본 논문에서는 FMCW 레이다 기반으로 휴먼 모션 인식을 위한 레이다 영상 추출 알고리즘을 제안하였다. 3D(거리-속도-각도) 스펙트럼을 생성하였고, 각 좌표방향으로 압축을 통해 세 개의 마이크로-프로파일 영상을 생성하였다. 이때 몸으로부터 반사된 신호를 억제하기 위한 클러터 억제 알고리즘을 적용하였다. 생성된 거리, 도플러. 각도-영상을 향후 영상처리 및 분류기에 적용함으로써, 다양한 모션 종류를 구별할 수 있을 것으로 판단된다.

4공 가솔린 분사기의 2중 분무 사이에서 연료 액적들의 유동특성 (The Flow Characteristics of Fuel Droplets between the Twin Spray for 4-hole Gasoline Injectors)

  • 김원태;강신재;노병준
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.484-495
    • /
    • 2003
  • This study investigates the flow characteristics of fuel droplets between twin spray for the 4-hole injector used a 4-valve gasoline engine. The injectors for this study were the three types of 4-hole gasoline injector in which orifice diameter was 0.24mm. The spray behavior of twin spray was investigated by means of visualization employed stroboscope. A PDPA system was employed to simultaneously measure the size and velocity of fuel droplets. The 3 dimensional mean velocities. droplet size distributions, SMD and joint probability density function of velocity and droplet size are analyzed at the center of the spray and the center region of twin spray. As a result, the configurations of injector exit such as orifice interval and length of outlet, are very important factors that affect the flow characteristics of fuel droplets at the center region of twin spray.

항공기용 추적레이더 시험을 위한 시험장비의 설계 및 제작 (A Design and Fabrication of Test Equipment for Airborne Tracking Radar Test)

  • 윤승구;박승욱;권준범;정만식
    • 한국군사과학기술학회지
    • /
    • 제20권3호
    • /
    • pp.352-361
    • /
    • 2017
  • This paper proposes a design and fabrication of the test equipment that is implemented as a part of the airborne tracking radar inspection under the environment of indoor simulation. This test equipment provides controlling the operation status of airborne tracking radar and replicating the velocity and range information of target by generating a variety of target signal. This is mainly composed of radar operation controller, target signal generator, horn antenna driving devices. Radar operation controller is able to perform the controlling of radar operation mode and monitoring in real time by serial communication. Target signal generator is generated doppler signal and range delayed signal using virtual target of RF-band. Horn antenna driving devices perform a role of target simulating exercise. In the end, the performance is demonstrated using experiment results of test equipment for airborne tracking radar.

다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석 (Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP)

  • 지주연;박승용;이광우;박경민;황순홍;김동호;이영준
    • 한국환경과학회지
    • /
    • 제22권2호
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

경항부 수기요법과 한방 목 크림이 목 주름과 안면 혈행에 미치는 영향 연구 (Influence of The Neck acupressure massage and The Neck Cream Including Korean Herbal Extract on The Neck Wrinkles and Facial Blood Circulation.)

  • 김은주;김지성;유선혜;노호식;김덕희;김한곤;조가영
    • 대한한의정보학회지
    • /
    • 제15권1호
    • /
    • pp.85-91
    • /
    • 2009
  • Objectives: We investigated the influence of the neck acupressure massage and the neck cream including korean herbal extract on the neck wrinkles and blood circulation. Methods: Korean female($37.47{\pm}3.66$ years, n=18) aged 30-39 years were participated in this study. We measured the neck wrinkles with PRIMOS(GFMesstechnik GmbH, Germany) and blood circulation of neck and facial skin with Laser Doppler Imaging-Periscan PIM II(Perimed AB, Sweden). Results: The neck wrinkles were significantly decreased after applying neck cream. But when with the neck acupressure massage, the neck wrinkles were decreased 2-fold than applying only the neck cream. The skin blood circulation was significantly increased on the neck and facial skin immediately after the neck acupressure massage. But this effect was not significantly different after 8 weeks Conclusions: This result suggests that the neck acupressure massage can improve the anti-wrinkles effect of the neck cream including Korean herbal extract.

  • PDF

실리콘 보형물을 이용한 유방확대술 후 발생한 심부정맥혈전증 1례 (Case Report of Deep Vein Thrombosis after Cohesive Silicone Gel Implant Basedaugmentation Mammoplasty)

  • 김도훈;양은정;임소영;변재경;문구현;오갑성;방사익
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.703-706
    • /
    • 2011
  • Purpose: Augmentation mammoplasty by cohesive silicone gel implant is becoming more popular nowadays. Many types of complications have been reported, such as hematoma, seroma, infection, capsular contracture and etc. But there were no report of deep vein thrombosis(DVT) after augmentation mammoplasty in Korea. The authors experienced one case of DVT after augmentation mammoplasty using a cohesive silicone gel implant. Methods: A 38-year-old woman with breast cancer underwent reconstruction by tissue expander and augmentation mammoplasty by cohesive silicone gel implant, and exchange of expander to cohesive silicone gel implant. The operation was finished without any complicating event. On 4th day after the operation, the patient complained of intermittent right lower leg pain. By doppler ultrasonography, the patient was diagnosed with acute venous thrombosis of the popliteal vein, posterior tibial vein and peroneal vein. Results: Intravenous heparinization and oral warfarin were started immediately and elastic compression stocking was applied. Intravenous heparinization was continued until INR (blood coagulation unit) reached to target levels. The patient was discharged on 11th day of operation with oral warfarin. Other complication has not been reported after 10 weeks of operation. Conclusion: To our knowledge, this is the first report of DVT after silicone implant based breast augmentation.