• Title/Summary/Keyword: Doppler Profile

Search Result 78, Processing Time 0.026 seconds

PIV System for the Flow Pattern Anaysis of Artificial Organs ; Applied to the In Vitro Test of Artificial Heart Valves

  • Lee, Dong-Hyeok;Seh, Soo-Won;An, Hyuk;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.489-497
    • /
    • 1994
  • The most serious problems related to the cardiovascular prothesis are thrombosis and hemolysis. It is known that the flow pattern of cardiovascular prostheses is highly correlated with thrombosis and hemolysis. Laser Doppler Anemometry (LDA) is a usual method to get flow pattern, which is difficult to operate and has narrow measure region. Particle Image Velocimetry (PIV) can solve these problems. Because the flow speed of valve is too high to catch particles by CCD camera, high-speed camera (Hyspeed : Holland-Photonics) was used. The estimated maximum flow speed was 5m/sec and maximum trackable length is 0.5 cm, so the shutter speed was determined as 1000 frames per sec. Several image processing techniques (blurring, segmentation, morphology, etc) were used for the preprocessing. Particle tracking algorithm and 2-D interpolation technique which were necessary in making gridrized velocity pronto, were applied to this PIV program. By using Single-Pulse Multi-Frame particle tracking algorithm, some problems of PIV can be solved. To eliminate particles which penetrate the sheeted plane and to determine the direction of particle paths are these solving methods. 1-D relaxation fomula is modified to interpolate 2-D field. Parachute artificial heart valve which was developed by Seoul National University and Bjork-Shiely valve was testified. For each valve, different flow pattern, velocity profile, wall shear stress and mean velocity were obtained.

  • PDF

Developing an Instrument Ensuring Reliable Contact Conditions for Contact-Type Area-varying Capacitive Displacement Sensors (접촉식 면적변화형 정전용량 변위센서의 접촉 안정성을 위한 기구의 개발)

  • Kim, Sung-Joo;Lee, Won-Goo;Moon, Won-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1147-1156
    • /
    • 2011
  • A contact-type area-varying capacitive displacement sensor, or CLECDiS, can measure displacements over millimeter ranges with nanometer resolution. However, a small changes in the contact condition due to the surface profile or friction, which are inherent characteristics of contact-type sensors, lead to significant distortion of the output signal. Therefore, ensuring reliable contact conditions during CLECDiS measurements is the most important area to be improved in their actual use. Herein, in order to design an instrument for ensuring reliable contact conditions, the contact condition is analyzed by characterizing the signal distortion, observing the pressure distribution between the contacting surfaces, and measuring the motional errors of the sensor using a laser Doppler vibrometer (LDV). The manufactured instrument enables a CLECDiS to be used in an ultraprecise positioning system with improved reliability.

Serum interleukin-6, tumor necrosis factor-α and adiponectin levels in Kawasaki disease (가와사키병 환자의 혈청 interleukin-6, tumor necrosis factor-α, Adiponectin 치에 대한 연구)

  • An, Jung;Kim, Han Gyu;Sohn, Sejung;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose : Adiponectin is an endogenous modulator of vascular remodeling that suppresses vascular inflammation. However, the role of adiponectin in Kawasaki disease (KD) has not been elucidated. The purpose of this study is to investigate the correlation between serum adiponectin level and several parameters, such as interleukin (IL)-6, tumor necrosis factor $(TNF)-{\alpha}$, lipid profile, and C reactive protein (CRP), and to clarify the association between adiponectin and cardiac function. Methods : Twenty-two KD patients (22 patients in acute phase and 20 patients in subacute phase) were enrolled in the study group. The control group consisted of 31 subjects (13 febrile patients and 18 healthy children). Both groups underwent blood sampling and tissue Doppler imaging (TDI). Results : CRP was significantly increased in the KD group compared with the control group. There were no significant differences in serum $TNF-{\alpha}$, IL-6, and adiponectin levels between groups. However, a negative correlation was found between adiponectin level and CRP level or platelet count. Systolic myocardial velocity and A myocardial velocity measured by TDI were decreased significantly in the acute KD group compared with the subacute KD group and control group. Positive correlations were found between adiponectin level and systolic myocardial velocity or A myocardial velocity. Conclusion : In acute KD patients, low adiponectin level was related to severe inflammatory reactions and decreased left ventricular functions.

Velocity and Discharge Measurement using ADCP (ADCP를 이용한 유속과 유량 측정)

  • Lee, Chan-Joo;Kim, Won;Kim, Chi-Young;Kim, Dong-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.10 s.159
    • /
    • pp.811-824
    • /
    • 2005
  • The ADCP is an instrument based on Doppler effect, which measures discharge of a river in a short time while crossing it. In this study we aim to make a comparison of the discharge results from a moving-vessel ADCP with those measured by velocity-area method at the same cross-section, and to investigate the characteristics of velocity and discharge data using ADCP. Bathymetry measured by ADCP almost coincides with that by direct depth measurements. Because velocity data from ADCP are essentially instantaneous, individual velocity profiles obtained by ADCP are rather different from time-averaged velocity profiles. But spatially averaged velocity profiles of the individual ADCP data near the comparable verticals have similar vertical velocity pattern with the time-averaged ones. The average velocity profile from repeatedly crossed data is also similar with the time-averaged one. In case of the velocity distribution, individual and spatially averaged data for the sub-width of mid-section method Have good agreement with those by velocity-area method. Discharge data determined by averaging several ADCP measurement transects have $0.1\%{\~}9.3\%$ of difference with those from velocity-area method, and as the number of measurement increases, the relative difference to the velocity-area method decreases.

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF

Analysis of Target Identification Performances Using Bistatic ISAR Images (바이스태틱 ISAR 영상을 이용한 표적식별 성능 분석)

  • Lee, Seung-Jae;Lee, Seong-Hyeon;Kang, Min-Seok;Yang, Eunjung;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.566-576
    • /
    • 2016
  • Inverse synthetic aperture radar(ISAR) image generated from bistatic radar(Bi-ISAR) represents two-dimensional scattering distribution of a target, and the Bi-ISAR can be used for bistatic target identification. However, Bi-ISAR has large variability in scattering mechanisms depending on bistatic configurations and do not represent exact range-Doppler information of a target due to inherent distortion. Thus, an efficient training DB construction is the most important factor in target identification using Bi-ISARs. Recently, a database construction method based on realistic flight scenarios of a target, which provides a reliable identification performance for the monostatic target identification, was applied to target identification using high resolution range profiles(HRRPs) generated from bistatic radar(Bi-HRRPs), to construct efficient training DB under bistatic configurations. Consequently, high identification performance was achieved using only small amount of training Bi-HRRPs, when the target is a considerable distance away from the bistatic radar. Thus, flight scenarios based training DB construction is applied to target identification using Bi-ISARs. Then, the capability and efficiency of the method is analyzed.

An Study on flow Discharge Calculation using Surface Velocity (비접촉식 유속계의 표면유속을 이용한 유량산정방법에 관한 연구)

  • Roh, Youngsin;Lee, Sin Jae;Kim, Dae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.230-230
    • /
    • 2020
  • 하천 유량측정을 위한 표면유속계는 비접촉식 방식이기 때문에 현장에서의 측정이 간편하고, 비교적 안전하기 때문에 홍수시 유량측정에 널리 이용되고 있다. 비접촉식 유속계가 가지고 있는 이러한 장점으로 전자파표면유속계의 활용이 점차 증가하고 있으며, 영상유속계와 같은 비접촉 측정방식의 활용방안 마련에 대한 연구개발 등이 꾸준히 진행되어 왔다. 최근에는 고정식으로 상시 운영이 가능한 표면유속계 등이 출시되어 소규모 하천이나 수로에서의 상시 유량측정에 활용되고 있다. 다만, 이러한 비접촉식 유속계는 표면의 유속을 측정하기 때문에 유량산정을 위해서는 평균유속으로의 환산이 필요하지만, 현재까지는 평균유속 환산계수를 사용하여 표면유속을 평균유속으로 환산하는 방법이 유일하게 활용되고 있다. 하지만, 실제 하천에서는 단면 및 하도형태, 하상조건, 수리특성 및 유속분포 등의 다양한 조건에 따라 환산계수가 결정되기 때문에 이를 단순히 일률적으로 적용하는 것은 곤란하며, 이로 인해 과거 오랫동안 표면유속을 평균유속으로 환산하기 위한 다양한 연구가 진행되었지만, 실제 다양한 조건의 하천에 적용할 수 있는 표준화된 방법은 아직까지 제시되지 못하고 있다. 현재까지, 고정식으로 설치된 유속계로부터 측정된 유속을 평균유속으로 환산하는 방법으로는 국내외적으로 지표유속법(Index Velocity Method)과 유속분포법(Velocity Profile Method)이 대표적이며, H-ADCP (Horizontal-Acoustic Doppler Velocity Profiler) 또는 UVM(Ultrasonic Velocity Meter) 등과 같은 초음파유속계를 활용한 자동유량측정시설의 유량산정방법으로 활용되고 있다. 이러한 방법들은 고정된 유속계의 측정유속을 지표유속(Vi)으로 하여 다양한 범위의 실측된 평균유속과의 관계를 개발하여 활용하거나, 지표유속을 매개로 개수로 단면의 이론적인 유속분포를 추정하여 평균유속을 산정한다. 이러한 지표유속을 활용하는 방법들에서 공통적으로 중요한 것은 하천단면의 최대유속(Vmax)이 가장 좋은 지표유속이라는 것이다. 따라서 국제기준에서는 지표유속을 측정하는 유속계의 가장 바람직한 위치로 유심부(core flow)를 권장하고 있다. 하지만, 접촉식 유속계의 경우 유심부 설치가 매우 어렵고 많은 비용이 들기 때문에, 비접촉식 유속계를 활용하여 하천단면의 최대유속을 측정할 수 있다면, 가장 효율적인 고정식 측정방법이 될 수 있을 것이다. 따라서, 본 연구에서는 비접촉식 표면유속계의 고정식 유량측정 활용성 및 적용성을 검토할 목적으로 표면유속에 대한 유량산정방법을 검토하였다. 이를 위해 24GHz의 주파수를 갖는 레이다표면유속계인 Sensoflow를 낙동강 수계 길안천에 위치한 안동시(대사3교)에 고정설치하여 표면유속을 지표유속으로 수집하였다. 다양한 유량규모에서 측정한 실측 표면유속과 수집된 표면유속을 지표유속으로 활용하여 지표유속관계를 개발하였으며, 산정된 유량을 기존 수위-유량관계곡선식의 환산유량과 비교하여 표면유속의 지표유속 활용성을 검토하였다.

  • PDF

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.