• 제목/요약/키워드: Doppler

검색결과 2,253건 처리시간 0.025초

Ocean Surface Current Retrieval Using Doppler Centroid of ERS-1 Raw SAR Data

  • Kim Ji-Eun;Kim Duk-jin;Moon Wooil M.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.590-593
    • /
    • 2004
  • Extraction of ocean surface current velocity offers important physical oceanographic parameters especially on understanding ocean environment. Although Remote Sensing techniques were highly developed, the investigation of ocean surface current using Synthetic Aperture Radar (SAR) is not an easy task. This paper presents the results of ocean surface current observation using Doppler Centroid of ERS-1 SAR data obtained off the coast of Korea peninsula. We employed the concept, in which Doppler frequency shift and the ocean surface current are closely related, to evaluate ocean surface current. Moving targets cause Doppler frequency shift of the back scattered radar waves of SAR, thus the line-of-sight velocity component of the scatters can be evaluated. The Doppler frequency shift can be measured by estimating the difference between Doppler Centroid of raw SAR data and reference Doppler Centroid. Theoretically, the Doppler Centroid is zero; however, squinted antenna which is affected by several physical factors causes Doppler Centroid to be nonzero. The reference Doppler Centroid can be obtained from measurements of sensor trajectory, attitude and Earth model. The estimated Doppler Centroid was compensated by considering the accurate attitude estimation of ERS-1 SAR. We could verify the correspondence between the estimated ocean surface current and observed in-situ data in the error bound.

  • PDF

속도 추정 시 부가 잡음의 영향을 억제하기 위한 결정 궤환 적응형 대역 제한 방법에 대한 연구 (Decision Feedback Doppler Adaptive Band-Limit Algorithm for Maximum Doppler frequency Estimation)

  • 박구현;한상철;류탁기;홍대식;강창언
    • 한국통신학회논문지
    • /
    • 제28권11C호
    • /
    • pp.1111-1117
    • /
    • 2003
  • 이동 통신 시스템에서 이동체의 속도 추정은 수신신호의 최대 도플러 주파수를 찾는 과정이다. 하지만 실제적인 이동 통신 환경에서 이동체의 속도 추정은 부가된 잡음의 영향으로 많은 왜곡을 가지게 된다. 본 논문에서는 이동 통신 환경에서 최대 도플러 주파수 추정 시 부가 잡음의 영향을 억제하기 위한 결정 궤환 적응형 대역 제한(Decision Feedback Doppler Adaptive Band-Limit : DF-DABL) 알고리즘을 제안한다. 제안된 알고리즘에서는 잡음의 2차 통계 특성을 대역 제한 방법을 통하여 신호의 특성과 일치하게 함으로서 부가된 잡음의 영향을 효과적으로 제거한다. 특히 제안된 방법에서는 신호대잡음비 (SNR)와 같은 추가 채널 정보를 필요로 하지 않는다.

광음향 효과를 이용한 $CO_2$ 레이저 도플러 속도 측정기 (Laser Doppler Velocimetry Using the Photoacoustic Effect of $CO_2$ Laser)

  • 최종운;유문종
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.36-40
    • /
    • 2004
  • A new laser Doppler velocimeter employing a $CO_2$ laser has been developed by using its photoacoustic effect. A change in the pressure of a discharge, induced by mixing of a returned wave with an originally existing wave inside the cavity, is employed to detect the Doppler frequency shift. We found that a Doppler frequency shift as much as 34 KHz was detected, and also a good linear relationship between the velocity and the Doppler frequency shift was obtained.

마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로- (Development of Portable Arrhythmia Moniter Using Microcomputer(I))

  • 이명호;안재봉
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과 연구 (Study of Doppler Fluid Effects of Carbonated Water in a Bi-directional Flow Phantom Model)

  • 김지혜;허영철
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.83-91
    • /
    • 2024
  • 본 연구에서는 양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과를 확인하고자 하였다. 양방향 흐름 팬텀 모델은 동맥과 정맥의 흐름을 구현한 것이며 이중 수조 구조를 통해 유체의 순환이 가능하고 팬텀의 크기를 줄일 수 있게 고안되었다. 사용된 유체는 탄산수, 소금물, 설탕물, 증류수를 이용하였고 수조 표면에서 깊이 1.5 cm, 3.0 cm에서 초음파 B-mode와 컬러 도플러 효과를 이용해 초음파 스캔하였다. 컬러 도플러 효과는 탄산수, 소금물, 설탕물, 증류수 모두 도플러 시프트 효과를 나타냈으나 탄산수의 도플러 시프트 효과가 가장 높았고 깊이에 따른 변화에서도 탄산수의 도플러 시프트 효과 편차가 가장 적었다. 결론적으로 탄산수의 도플러 유체 사용 가능성을 확인할 수 있었고 탄산수의 기포가 적혈구의 도플러 반사체 역할을 하고 있음을 확인하였다. 따라서 도플러 초음파 팬텀 제작에서 혈액 모방액과 유사한 물질로 탄산수를 이용한 추가 연구가 필요하며 이에 본 연구가 기초자료를 제공할 것이라 사료 된다.

The Use of Contrast-Enhanced Color Doppler Ultrasound in the Differentiation of Retinal Detachment from Vitreous Membrane

  • Sang-Suk Han;Seung-Kook Chang;Jung-Hee Yoon;Young-Joon Lee
    • Korean Journal of Radiology
    • /
    • 제2권4호
    • /
    • pp.197-203
    • /
    • 2001
  • Objective: To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. Materials and Methods: In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Results: Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Conclusion: Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD.

  • PDF

초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치- (Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System-)

  • 백광렬;안영복
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.139-146
    • /
    • 1986
  • 본 논문은 tms 32010이라는 디지탈 신호 처리용소자를 사용하여 초음하 펄스 도플러 장치를 구현한 것이다. 도플러 장피란 초음파 신호의 송수신 과정에서 발생하는 도플러 효과를 이용하여 혈류의 속도를 측정하는 장치이다. 한 점에서의 속도를 측정하는 단일채널 도플러 장치에서는 실시간 고속 푸리에 변환기를 구현하여 도플러 주하수의 스펙트럼을 측정함으로서 혈류속도를 측정하며 초음파 빔의 일직선상에서의 여러점을 동시에 측정하는 다중채널 도플러 장치에서는 영점교차검출기를 구현하여 평균주파수를 측정하였다. 자중채널 장치는 직렬처리법을 사용하여 하드웨어를 간단히 하였으며 8점에서의 속도를 측정할 수 있도록 하였다.

  • PDF

PW 도플러 시스템에서 Base Line 이동 기법을 이용한 오디오 신호 처리 방법 (Audio Processing Algorithm Using Base Line Shift Method in Pulsed Doppler Systems)

  • 김기덕;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권3호
    • /
    • pp.275-281
    • /
    • 1999
  • 현재 널리 쓰이고 있는 PW 도플러 시스템 주파수가 나이퀴스트 주파수를 초과할 경우 스텍트럼 aliasing 현상에 의하여 정확한 혈류 속도의 측정을 할 수 없다는 문제점을 가지고 있다 . 도플러 스펙트럼의 aliasing 현상을 극복하기 위하여 통상적으로 기준선 (Base Line) 이동기법을 사용하고 있으나 도플러 오디오 신호는 aliasing 된채로 남게 된다. 이 논문에서는 주파수 천이 및 필터링 기법들을 적절히 적용하여 기준선 이동시 도플러 스텍트럼과 오디오 신호의 aliasing 현상을 함께 제거할 수 있는 기법을 제안한다. 제안된 방법은 단방향 혈류 성분을 검사하는 경우 aliasing 현상 없이 측정 가능한 도플러 주파수를 나이퀴스트 주파수의 두배인 PRF 까지 증가되도록 한다. 실제 시스템에서 얻어진 신호를 이용하여 제안된 방법을 실험적으로 검증하였다.

  • PDF

신경초음파 검사에서 Doppler소견의 판독 (Interpertation of Doppler Indicies in Neurosonologic Examinations)

  • 김제
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.47-54
    • /
    • 1999
  • The Doppler in neurosonologic examination could be applied to blood flow to determine its movement, the direction of its movement, and how fast it is. Indicies of the Doppler study denoted velocity, direction, and amount of RBC in the examined vessel. Systolic. diastolic, and mean blood flow velocities represent velocity of RBCs in a sample volume. Blood flow direction to the probe means direction of RBC to the probe. Size of amplitude displays toe amount of the RBCs passing the sample volume. Spectral broadening means presence of turbelence. The RBC movements and hemodynamics at the examined vessels can be estimated by analysis of Doppler indicies The formation and meaning of each of neurosonologic Doppler study is described in the present review.

  • PDF

Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구 (Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study)

  • 김영호;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF