• 제목/요약/키워드: Door to Door

검색결과 1,716건 처리시간 0.03초

Multi LED를 이용한 철도차량용 Door Status Indication Lamp (Development of Multi LED type Door Status Indication Lamp for rolling stock)

  • 서범원;최재성;김동일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1466-1472
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

폭압에 의한 방폭문의 구조적 안정성에 대한 연구 (A Study On Structural Stability Of Blast Door by Blast Pressure)

  • 김남혁;박관진;이근오
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.8-15
    • /
    • 2016
  • The purpose of this study is to design a model with the structural stability so as not to lose the operational function due to structural plastic or fail of a sliding blast door by blast pressure to this aim, a numerical simulation was performed using full-size experiments and M&S (Modeling & Simulation) of the sliding blast door. The sliding blast door ($W3,000{\times}H2,500mm$) under the blast load is in the form of a sliding type 2-way metal grill, which was applied by a design blast pressure (reflected pressure $P_r$) of 17 bar. According to the experimental results of a real sliding blast door under blast load, the blast pressure reached the sliding blast door approximately 4.3 ms after the explosion and lasted about 4.0 ms thereafter. The maximum blast pressure($P_r$) was 347.7 psi (2,397.3 kPa), it is similar to the UFC 3-340-02 of Parameter(91 %). In addition, operation inspection that was conducted for the sliding blast door after real test showed a problem of losing the door opening function, which was because of the fail of the Reversal Bolt that was installed to prevent the shock due to rebound of the blast door from the blast pressure. According to the reproduction of the experiment through M&S by applying the blast pressure measurement value of the full-size experiments, the sliding blast door showed a similar result to the full-size experiment in that the reversal bolt part failed to lose the function. In addition, as the pressure is concentrated on the failed reversal bolt, the Principal Tensile Failure Stress was exceeded in only 1.25 ms after the explosion, and the reversal bolt completely failed after 5.4 ms. Based on the result of the failed reversal bolt through the full-size experiment and M&S, the shape and size of the bolts were changed to re-design the M&S and re-analyze the sliding blast door. According to the M&S re-analysis result when the reversal bolt was designed in a square of 25 mm ($625mm^2$), the maximum pressure that the reversal bolt receives showed 81% of the principal tensile failure stress of the material, in plastic stage before fail.

LFT소재 특성을 고려한 Door Carrier Plate 변형 해석 (Warpage analysis of a Door Carrier Plate in the injection molding Considering the characteristics of LFT)

  • 유호영;박시환
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.3625-3630
    • /
    • 2013
  • 도어 모듈은 모듈화의 대표적인 예로 여러 부품들은 모듈형태로 완성하여 완성차 업체의 원가절감 및 조립시간 단축, 품질 향상 등에 큰 기여를 이루었다. 주요 부품중의 하나인 Door carrier plate는 주로 steel을 이용한 press 성형이 주였으나 최근에는 PP-LFT(유리 장섬유 강화PP)를 사용한 사출 공법을 적용함으로써 형상자유도를 높혀 모듈에 부착되는 많은 종류의 부품들을 통합할 수 있게 되었으며 중량 절감을 이룰 수 있게 되었다. 하지만 사출 성형시 제품의 형상 및 gate위치 설정의 한계성과, LFT의 특성에 의하여 변형이 비교적 심해 일반적으로 시사출 진행 후 보상 가공을 진행하여 조립성을 개선한다. 이러한 사후 수정 공정은 금형의 품질 저하 및 생산원가 상승의 주요인이다. 부분적으로 사출 CAE를 적용하여 warpage정도를 예측하나 그 신뢰성 확보에 어려움을 겪고 있다. 따라서 LFT를 사용하는 Door carrier plate에 대한 해석 신뢰성을 확보할 수 있는 기법으로 hyper-mesh에서 1차 mesh작업 후 moldlfow 자체 tool을 이용하여 mesh의 두께 구현성을 높혔으며, fiber orientation해석을 위하여 ARD-RSC model을 적용하였다.

스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구 (Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate)

  • 김민재;민세홍
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.59-64
    • /
    • 2016
  • Platform Screen Door System (PSD)는 지하철 승객의 편의 및 안전을 위해 설치되기 시작하였고, 현재 전국 9개 운영기관이 관리하고 있는 824개 역사 중 전체의 71.8%에 해당하는 592개 역이 PSD를 운영 중에 있다. 본 연구에서는 전동차 정차 위치에 따른 PSD와 전동차 가동문 사이의 개폐율 변화를 분석하였고, 수도권 지하철을 운행 중인 기관에서 제공받은 재차인원 자료 분석 및 피난시뮬레이션을 통해 각 역사별 피난소요시간을 산정하였다. 연구결과 승객이 매우 혼잡하게 밀집되는 일부 고밀도 역사에서는 PSD 개폐율에 따라 매우 위험한 상황이 초래될 수 있음을 알 수 있었다. 특히 정위치에서 7 m 벗어난 곳에 정차할 경우 PSD의 고정 안전보호벽과 맞물려 열차 출입문 절반 이상이 폐쇄되는 것으로 분석되었다. 이러한 문제점을 개선하기 위해 기(旣) 설치된 PSD 고정안전보호벽을 모두 개폐 가능한 비상문으로 교체 및 개량하는 것을 제안한다.

형태 제약과 출입구를 고려한 설비 배치 및 복도 구조 디자인 (Factory Layout and Aisle Structure Design Considering Dimension Constraints and Door Locations)

  • Chae-Bogk Kim
    • 산업경영시스템학회지
    • /
    • 제26권3호
    • /
    • pp.58-66
    • /
    • 2003
  • The cut tree approach of Montreuil and Ratliff [16] and eigenvector approach [10] are used to automatically draw a feasible facility layout with aisle structure. The department arrangement can minimize an aisle distance criterion considering door locations and dimension constraints. The aisle distance is measured by the door to door distance between departments. An eigenvector and cut tree approaches [1] are implemented based on the branch and bound technique in Kim et al. [2] in order to obtain feasible layouts. Then, the algorithm to fix the door location of each department is developed. After the door locations are determined, the factory layout is evaluated in terms of aisle distance. The aisle structure is obtained by expanding the original layout. The solution is kept until we will find better factory layout. The proposed approach based on the branch and bound technique, in theory, will provide the optimal solution. If the runs are time and/or node limited, the proposed method is a strong heuristic. The technique is made further practical by the fact that the solution is constrained such that the rectangular shape dimensions length(l) and width(w) are fixed and a perfect fit is generated if a fit is possible.

방사선촬영 중 제어실 문의 열린 방향에 따른 차폐효과 (Shielding Effect according to the Direction of Control Room Door Opening during Radiography)

  • 최원근;김정훈;강보선;배석환;임창선
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3347-3352
    • /
    • 2010
  • 방사선촬영검사 시에는 제어실 문을 닫고 촬영하도록 권고하고 있으나 응급 환자나 소아 환자 등의 방사선 촬영검사 시에는 발생할 수 있는 긴급 상황에 대한 신속한 조치 수행을 위해서 불가피하게 제어실 문을 열어 놓은 상태에서 촬영해야 하는 경우가 있다. 또한 일반 단순촬영의 경우에도 환자들의 대기시간 단축 등을 고려할 때 촬영시 제어실 문을 열어 두는 것이 더 효율적일 수 있다. 이러한 상황을 감안하여 제어실 문을 열어 놓고 촬영업무를 수행하는 경우에 방사선작업종사자에 대한 방사선피폭선량을 평가하여 방사선피폭을 최소화하면서 업무의 효율을 올릴 수 있는 방안을 모색하고자 본 연구를 수행하였다. 실제 선량률은 유리선량계를 이용하여 측정하였으며, 제어실 문이 열린 상태에서 촬영 시 방사선작업종사자 위치에서 의 선량률은 주당 100 mR(약 0.88 mGy)을 약 2.3배 초과하는 2.02 mGy가 측정되었다. 이 결과를 통해 문이 열린 경우에는 상당량의 산란선이 작업종사자의 피폭선량을 증가시킴을 알 수 있었으며, 제어실 문이 열린 상태에서 촬영할 경우 작업종사자의 과다피폭 가능성이 매우 높다는 것을 확인하였다. 또한 몬테카를로 전산 모의실험을 수행하여 동일한 조건에서도 제어실 문의 방향에 따라 방사선작업종사자가 위치한 곳의 선량률을 대략 1/100까지 감소시킬 수 있음을 확인하였다. 결론적으로, 제어실 문을 열고 촬영하더라도 제어실 문의 방향에 따라 동일한 차폐효과를 기대할 수 있으므로 방사선차폐시설을 함에 있어 이에 대한 고려가 요구된다.

3,4호선 도시철도 전동차 도어엔진의 개발 역사에 관한연구 (A Study on History of Rolling Stock Door Engines of Seoul Metro Line No.3 and No.4)

  • 장성철;이찬희;전관수;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1352-1359
    • /
    • 2010
  • It is said that the number of people using public transportation has risen about 220 thousand over 3 years which was 1019 people average a day in 2006 and 1041 people last year. It is also said that the number of people using subway has increased by 198 thousand and the number of people using bus by 22 thousand. Can you imagine how many door engines work at the same time if we count Metro line no.1 to no.4 which consist of total 120 subway stations? A train has 80 door engines and Metro line trains have 9600 door engines all together. Which explains it quite simple how much Satefy, Durability and Sustainability need to be focused in Door Engines. Although it's not the whole part of door engines in Seoul Metro Line, And Metro No.4's door engines are operated by the method called mixture of mechanical type and belt type. And the last one is being used in the brand-new Metro train line No.3 which is being operated by electricity motor, instead of the old methods which use air pressure to operate a door engine. I'm sure you will agree that Safety is the first priority of Metro train and next follow comfortability and quickness. I think all I've talked so far make it the first step for the Safety of Metro train for you to understand the unit of a Door Engine.

  • PDF

지하상가 출입구 방풍문 설치에 따른 피난안전해석 (Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade)

  • 최영상;전흥균;추홍록
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-10
    • /
    • 2009
  • 지하상가는 특성상 출입구에 문을 설치할 경우 피난안전에 미치는 영향을 더 면밀하게 분석할 필요가 있다. 본 연구에서는 이미 사용 중에 있는 지하상가의 출입구 중 일부 출입구에 문을 설치하는 경우에 대해 CFAST로 화재시뮬레이션을 수행하고 그 결과를 building EXODUS 피난시뮬레이션의 위험인자로 활용하여 화재위험을 고려한 피난해석을 하였다. 지하상가의 6개 출입구 중에 2곳에 문을 설치할 경우에 대해 화재피난과 일반피난으로 나누어 1,088명에 대해 피난해석을 하였다. 일반피난의 경우는 문 설치에 따른 영향이 거의 없었으나 화재피난의 경우는 문 설치로 인해 약 110초의 피난지연이 발생하였다. 또 자동문이 설치된 경우는 자동문이 열리지 않을 때가 문 설치 전보다 670초 피난지연이 발생하였다. 따라서 자동문은 화재감지기와 연동하여 개방된 상태로 정지하도록 설치되어야 하고, 문을 설치할 경우 피난안전을 위해 피난유도표시를 보강하는 것도 필요하다.

전복시 차량 옆문의 구조해석 (Structural Analysis of Vehicle Side Door at Overturn)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제9권6호
    • /
    • pp.43-50
    • /
    • 2010
  • This study aims to analyze the structural safety by comparing deformation and equivalent stress of door with a stiffener or no stiffener when the door crashes against something in case of overturn. Three types are classified on the basis of the no stiffener model in the vehicle door. One is the type which has a stiffener. Another is the type which has no stiffener and the other is the type which has a hole in the stiffener. These three types are compared with each other by analyzing. This side door of vehicle is the automotive part about the kind of vehicle as Mercedes Benz E-Klasse scaled down as 1/18 times as the real size. The study model of vehicle door is modelled by CATIA program and it is analyzed by ANSYS.

A New Landmark-Based Visual Servoing with Stereo Camera for Door Opening

  • Han, Myoung-Soo;Lee, Soon-Geul;Park, Sung-Kee;Kim, Munsang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.100.2-100
    • /
    • 2002
  • In this paper we propose a new visual servoing method for door opening with mobile manipulator. We use an eye-to-hand system that stereo camera is mounted on mobile platform, and adopt the position-based method. The previous methods for door opening mostly used eye-in-hand system with mono camera and required predefined knowledge such as radius and position about door grip, which was mainly caused by using mono cam era. This is also a severe constraint for pursuing general-purpose algorithm for door opening. For overcoming such drawback, we use stereo camera and suggest a new method that detect the door grip and estimate its pose from stereo depth information without predefined knowledge. Al...

  • PDF