• Title/Summary/Keyword: Dominant frequency

Search Result 1,019, Processing Time 0.04 seconds

Acoustic resonance by length of acoustic baffle at Finned Tube bank (핀-튜브군에서 배플 길이에 따른 음향공진)

  • 방경보;류제욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF

A Study on the Characteristics of Cooperating Charge considering Dominant Frequency (주 주파수를 고려한 협동장약 특성에 관한 연구)

  • Kim Jong-In;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.316-323
    • /
    • 2005
  • As a result of waveform analysis, the separation of waveform found that high frequency well accomplishes but low frequency doesn't accomplish that. The data which measured less than 60 Hz and more than 60 Hz was analysed to examine the relation between cooperating charge and frequency. The measured data of more than 70 Hz was also analysed to consider the characteristics of high frequency.

Dynamic Response of Arch Structure according to Natural Frequency Ratio between Arch and Columns (아치구조와 기둥간의 고유진동수비에 따른 아치구조물의 동적응답특성)

  • Seok, Keun-Young;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.3
    • /
    • pp.65-72
    • /
    • 2013
  • Long span arch structure is composed of arch as relatively flexible structure and column as relatively rigid structure. In this study, the characteristic of dynamic response is analyzed according to the natural frequency ratio between arch and columns. The result of analysis for arch as relatively vertical vibration mode is dominant, the influence of columns mainly appears at relatively high frequency band according to increase of 1st mode frequency in column. However, the dynamic characteristic of arch structure is expected to vary with not only frequency ratio but interaction between vibration modes of arch and columns.

Frequency Dependent Grounding Impedance As a Function of Soil Resistivity (대지저항률에 따른 접지임피던스의 주파수 의존성)

  • Bae, Sung-Bae;Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • A design criterion of grounding systems is commonly based on low frequency resistance in Korea. When lightning surges which have high frequency components are injected into the grounding system, the grounding impedance is greatly different from the static grounding resistance. This paper presents the grounding adimittance and phase on the frequency range from 100 [Hz] to 15 [MHz] using water tank simulating the grounding system in different water resistivities. As a result, capacitive effect is dominant over the frequency of 100 [kHz] at the water resistivity of 1,000 [$\Omega$ m]. On the other hand, the inductive characteristics appear at the low water resistivity. Consequently, dependence of grounding impedances on the frequency of injected current is strongly related to resistivity.

  • PDF

A Study of response Spectrums and characteristics of Time-Frequency Domain of Microearthquakes in the Central Part of South Korea (남한 중부지역 미소지진들의 응답 스펙트럼 및 시간-주파수 영역에서의 특성에 관한 연구)

  • 이전희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.72-82
    • /
    • 1999
  • The microearthquake and explosion events recorded in the seismic KNUE(Korea National University of Education) network were analyzed. The seismic data were recorded from Dec. 1997 to Dec. 1998. Total of 118 records consisted of 24 earthquake and 4 explosion events were instrumented at 6 stations. Spectral values increases as magnitude increases and the predominant frequency band expands to low frequency. zone as magnitude increases. Three-dimensional spectrograms(time frequency. amplitude) were also synthesized in order to discriminate microearthquakes and artificial underground explosions. The waves from microearthquakes show that frequency content of dominant amplitude appeared above 10 Hz and the discrimination can be performed in almost all the frequency domain of 3-d spectrogram.

  • PDF

Large deformations of a flexural frame under nonlinear P-delta effects

  • Afshar, Dana;Afshar, Majid Amin
    • Earthquakes and Structures
    • /
    • v.22 no.5
    • /
    • pp.517-526
    • /
    • 2022
  • In this paper, nonlinear P-delta effects are studied on the seismic performance, and the modal responses of a flexural frame, considering large deformations. Using multiple scales method, the nonlinear differential equations of motion are estimated, and the nonlinear interactions between the frame's degrees of freedom are outcropped. The results of time and frequency domain analyzes of a dynamic model are examined under internal resonance cases, and the linear and nonlinear responses are investigated in each modal cases. Also, changing the modal responses with respect to the amplitude and frequency of the harmonic forces is evaluated. It is shown that the dominant absorption of energy is in the first natural frequency of the frame, in the case of earthquake excitation, and when a harmonic force is applied to the frame, the peaks of the frequency domain responses depending on the frequency of harmonic force are in the first, and second or third natural frequency of the structure.

Assessment of Flood Frequency of Bankfull Discharge in Korea Rivers (국내 하천 강턱유량시의 홍수빈도 추정)

  • Son, Min-Woo;Lee, Du-Han;Kim, Chang-Wan;Kim, Myoung-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1571-1575
    • /
    • 2006
  • Channel form discharge which determines shape and character of a channel is named as dominant discharge. Assuming that fixed discharge flows in the fluvial plain for a long time, it is channel form discharge of a certain channel if it changes the fluvial plain into shape of the channel. Channel form discharge can be demonstrated by concept of bankfull or effective discharge. 1.01, 1.58, 2, 2.33 and 5 year flood discharge were used in order to determine channel form discharge. Each frequency discharge was determined by 80 year flood discharge by a research result conducted by Kim and Won. 1.01 year frequency discharge was selected as the most similar discharge to bankfull discharge. 1.58 year frequency discharge habitually used in Korea exceeded bankfull discharge.

  • PDF

Assessment of Flood Frequency of Bankfull Discharge in Korea Rivers (국내 하천 강턱유량시의 홍수빈도 추정)

  • Son, Min-Woo;Lee, Du-Han;Kim, Chang-Wan;Kim, Myoung-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1107-1111
    • /
    • 2006
  • Channel form discharge which determines shape and character of a channel is named as dominant discharge. Assuming that fixed discharge flows in the fluvial plain for a long time, it is channel form discharge of a certain channel if it changes the fluvial plain into shape of the channel. Channel form discharge can be demonstrated by concept of bankfull or effective discharge. 1.01, 1.58, 2, 2.33 and 5 year flood discharge were used in order to determine channel form discharge. Each frequency discharge was determined by 80 year flood discharge by a research result conducted by Kim and Won. 1.01 year frequency discharge was selected as the most similar discharge to bankfull discharge. 1.58 year frequency discharge habitually used in Korea exceeded bankfull discharge.

  • PDF

An Analysis of Bias-Dependent S11-Parameter in Multi-Finger MOSFETs (Multi-Finger MOSFET의 바이어스 종속 S11-파라미터 분석)

  • Ahn, Jahyun;Lee, Seonghearn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.15-19
    • /
    • 2016
  • The gate bias dependence of kink phenomenon with a large deviation from the resistance circle in Smith chart is observed in the frequency response of $S_{11}$-parameter for large multi-finger RF MOSFETs. For the first time, this bias dependence is analyzed by measuring magnitude and phase of $S_{11}$-parameter, input resistance and input capacitance. As a result, $V_{gs}$ dependent $S_{11}$-parameter is largely changed by the magnitude of input capacitance as well as dominant pole and zero frequencies of input resistance. At $V_{gs}=0V$, the kink phenomenon occurs in the high frequency region because of very small phase difference of $S_{11}$-parameter and high pole frequency of input resistance. However, the kink phenomenon at higher $V_{gs}$ is generated in the low frequency region owing to large phase difference and low pole frequency.

Adaptive-length pendulum smart tuned mass damper using shape-memory-alloy wire for tuning period in real time

  • Pasala, Dharma Theja Reddy;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • v.13 no.2
    • /
    • pp.203-217
    • /
    • 2014
  • Due to the shift in paradigm from passive control to adaptive control, smart tuned mass dampers (STMDs) have received considerable attention for vibration control in tall buildings and bridges. STMDs are superior to tuned mass dampers (TMDs) in reducing the response of the primary structure. Unlike TMDs, STMDs are capable of accommodating the changes in primary structure properties, due to damage or deterioration, by tuning in real time based on a local feedback. In this paper, a novel adaptive-length pendulum (ALP) damper is developed and experimentally verified. Length of the pendulum is adjusted in real time using a shape memory alloy (SMA) wire actuator. This can be achieved in two ways i) by changing the amount of current in the SMA wire actuator or ii) by changing the effective length of current carrying SMA wire. Using an instantaneous frequency tracking algorithm, the dominant frequency of the structure can be tracked from a local feedback signal, then the length of pendulum is adjusted to match the dominant frequency. Effectiveness of the proposed ALP-STMD mechanism, combined with the STFT frequency tracking control algorithm, is verified experimentally on a prototype two-storey shear frame. It has been observed through experimental studies that the ALP-STMD absorbs most of the input energy associated in the vicinity of tuned frequency of the pendulum damper. The reduction of storey displacements up to 80 % when subjected to forced excitation (harmonic and chirp-signal) and a faster decay rate during free vibration is observed in the experiments.