• 제목/요약/키워드: Dominant frequency

검색결과 1,019건 처리시간 0.032초

핀-튜브군에서 배플 길이에 따른 음향공진 (Acoustic resonance by length of acoustic baffle at Finned Tube bank)

  • 방경보;류제욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF

주 주파수를 고려한 협동장약 특성에 관한 연구 (A Study on the Characteristics of Cooperating Charge considering Dominant Frequency)

  • 김종인;강추원
    • 터널과지하공간
    • /
    • 제15권4호
    • /
    • pp.316-323
    • /
    • 2005
  • 파형 분석결과에 의하면 파형의 분리는 높은 주파수에서는 잘 이루어지지만 낮은 주파수에서는 파형분리가 잘 이루어지지 않는다. 협동장약과 주파수의 관계를 규명하기 위하여 측정된 자료를 60 Hz 미만의 경우와 60 Hz 이상의 경우로 분리하여 분석하였으며, 고주파 성분의 특성을 고려하기 위하여 70 Hz 이상의 측정 자료에 대해서도 분리하여 분석하였다.

아치구조와 기둥간의 고유진동수비에 따른 아치구조물의 동적응답특성 (Dynamic Response of Arch Structure according to Natural Frequency Ratio between Arch and Columns)

  • 석근영;강주원
    • 한국공간구조학회논문집
    • /
    • 제13권3호
    • /
    • pp.65-72
    • /
    • 2013
  • Long span arch structure is composed of arch as relatively flexible structure and column as relatively rigid structure. In this study, the characteristic of dynamic response is analyzed according to the natural frequency ratio between arch and columns. The result of analysis for arch as relatively vertical vibration mode is dominant, the influence of columns mainly appears at relatively high frequency band according to increase of 1st mode frequency in column. However, the dynamic characteristic of arch structure is expected to vary with not only frequency ratio but interaction between vibration modes of arch and columns.

대지저항률에 따른 접지임피던스의 주파수 의존성 (Frequency Dependent Grounding Impedance As a Function of Soil Resistivity)

  • 배성배;최종혁;박건훈;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2008
  • A design criterion of grounding systems is commonly based on low frequency resistance in Korea. When lightning surges which have high frequency components are injected into the grounding system, the grounding impedance is greatly different from the static grounding resistance. This paper presents the grounding adimittance and phase on the frequency range from 100 [Hz] to 15 [MHz] using water tank simulating the grounding system in different water resistivities. As a result, capacitive effect is dominant over the frequency of 100 [kHz] at the water resistivity of 1,000 [$\Omega$ m]. On the other hand, the inductive characteristics appear at the low water resistivity. Consequently, dependence of grounding impedances on the frequency of injected current is strongly related to resistivity.

  • PDF

남한 중부지역 미소지진들의 응답 스펙트럼 및 시간-주파수 영역에서의 특성에 관한 연구 (A Study of response Spectrums and characteristics of Time-Frequency Domain of Microearthquakes in the Central Part of South Korea)

  • 이전희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.72-82
    • /
    • 1999
  • The microearthquake and explosion events recorded in the seismic KNUE(Korea National University of Education) network were analyzed. The seismic data were recorded from Dec. 1997 to Dec. 1998. Total of 118 records consisted of 24 earthquake and 4 explosion events were instrumented at 6 stations. Spectral values increases as magnitude increases and the predominant frequency band expands to low frequency. zone as magnitude increases. Three-dimensional spectrograms(time frequency. amplitude) were also synthesized in order to discriminate microearthquakes and artificial underground explosions. The waves from microearthquakes show that frequency content of dominant amplitude appeared above 10 Hz and the discrimination can be performed in almost all the frequency domain of 3-d spectrogram.

  • PDF

Large deformations of a flexural frame under nonlinear P-delta effects

  • Afshar, Dana;Afshar, Majid Amin
    • Earthquakes and Structures
    • /
    • 제22권5호
    • /
    • pp.517-526
    • /
    • 2022
  • In this paper, nonlinear P-delta effects are studied on the seismic performance, and the modal responses of a flexural frame, considering large deformations. Using multiple scales method, the nonlinear differential equations of motion are estimated, and the nonlinear interactions between the frame's degrees of freedom are outcropped. The results of time and frequency domain analyzes of a dynamic model are examined under internal resonance cases, and the linear and nonlinear responses are investigated in each modal cases. Also, changing the modal responses with respect to the amplitude and frequency of the harmonic forces is evaluated. It is shown that the dominant absorption of energy is in the first natural frequency of the frame, in the case of earthquake excitation, and when a harmonic force is applied to the frame, the peaks of the frequency domain responses depending on the frequency of harmonic force are in the first, and second or third natural frequency of the structure.

국내 하천 강턱유량시의 홍수빈도 추정 (Assessment of Flood Frequency of Bankfull Discharge in Korea Rivers)

  • 손민우;이두한;김창완;김명환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1571-1575
    • /
    • 2006
  • 하도 형성 유량은 현재 하도의 형태와 특성을 결정하는 유량을 말하는 것으로 지배유량라고도 불린다. 지배유량과 동일한 개념에서 충적하천에서 장기간에 걸쳐 동일한 규모의 유량이 하도에 적용된다고 가정할 때, 현재의 하천과 같은 형상을 나타내게 만드는 유량이 하도 형성 유량이며, 이것은 크게 강턱유량과 유효유량의 개념으로 설명된다. 금회 연구에서는 국내에서 많이 이용되는 1.58년 빈도의 홍수량을 포함하여 각종 빈도의 홍수량을 결정하고, 이를 1차원 부등류 해석 프로그램에서 모의하여 수위 및 유량을 결정하였다. 하도 형성 유량 산정을 위해 이용된 홍수의 빈도는 1.01년, 1.58년, 2년, 2.33년, 5년이다. 각 빈도별 홍수량은 해당하천의 하천정비 기본계획에서 제시된 80년 빈도 홍수량과 무차원성장곡선을 이용하여 산정하였다. 오차분석 결과 조사된 전체 하천에서 1.01년 빈도의 홍수량이 강턱에 가장 근접하는 결과를 나타내었으며, 국내에서 관행적으로 이용하던 국내에서 관행적으로 이용되는 1.58년 빈도 홍수량은 강턱유량의 개념에서 하도 형성 유량에 접근할 때는 과대하게 평가되는 점을 확인할 수 있었다.

  • PDF

국내 하천 강턱유량시의 홍수빈도 추정 (Assessment of Flood Frequency of Bankfull Discharge in Korea Rivers)

  • 손민우;이두한;김창완;김명환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1107-1111
    • /
    • 2006
  • 하도 형성 유량은 현재 하도의 형태와 특성을 결정하는 유량을 말하는 것으로 지배유량라고도 불린다. 지배유량과 동일한 개념에서 충적하천에서 장기간에 걸쳐 동일한 규모의 유량이 하도에 적용된다고 가정할 때, 현재의 하천과 같은 형상을 나타내게 만드는 유량이 하도 형성 유량이며, 이것은 크게 강턱유량과 유효유량의 개념으로 설명된다. 금회 연구에서는 국내에서 많이 이용되는 1.58년 빈도의 홍수량을 포함하여 각종 빈도의 홍수량을 결정하고, 이를 1차원 부등류 해석 프로그램에서 모의하여 수위 및 유량을 결정하였다. 하도 형성 유량 산정을 위해 이용된 홍수의 빈도는 1.01년, 1.58년, 2년, 2.33년, 5년이다. 각 빈도별 홍수량은 해당하천의 하천정비 기본계획에서 제시된 80년 빈도 홍수량과 무차원성장곡선을 이용하여 산정하였다. 오차분석 결과 조사된 전체 하천에서 1.01년 빈도의 홍수량이 강턱에 가장 근접하는 결과를 나타내었으며, 국내에서 관행적으로 이용하던 국내에서 관행적으로 이용되는 1.58년 빈도 홍수량은 강턱유량의 개념에서 하도 형성 유량에 접근할 때는 과대하게 평가되는 점을 확인할 수 있었다.

  • PDF

Multi-Finger MOSFET의 바이어스 종속 S11-파라미터 분석 (An Analysis of Bias-Dependent S11-Parameter in Multi-Finger MOSFETs)

  • 안자현;이성현
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.15-19
    • /
    • 2016
  • 매우 큰 사이즈를 가진 multi-finger RF MOSFET의 $S_{11}$-parameter에서 스미스차트의 저항 circle 라인을 벗어나는 kink 현상의 게이트 바이어스 종속 특성이 관찰되었다. 이러한 바이어스 종속성은 $S_{11}$-parameter의 크기와 위상, 입력저항, 입력 커패시턴스의 주파수 응답곡선을 측정하여 최초로 분석되었다. 그 결과 입력 커패시턴스의 크기와 입력저항의 dominant pole과 zero 주파수에 의해 $V_{gs}$ 종속 kink 현상이 크게 변하는 것을 알 수 있다. $V_{gs}=0V$일 때 매우 적은 $S_{11}$-parameter 위상차와 입력저항의 높은 pole 주파수에 의해 고주파영역에서 kink 현상이 나타난다. 하지만 $V_{gs}$가 높아지면 $S_{11}$-parameter 위상차가 크게 증가하고 pole 주파수가 낮아져 저주파영역에서 kink 현상이 발생하게 된다.

Adaptive-length pendulum smart tuned mass damper using shape-memory-alloy wire for tuning period in real time

  • Pasala, Dharma Theja Reddy;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • 제13권2호
    • /
    • pp.203-217
    • /
    • 2014
  • Due to the shift in paradigm from passive control to adaptive control, smart tuned mass dampers (STMDs) have received considerable attention for vibration control in tall buildings and bridges. STMDs are superior to tuned mass dampers (TMDs) in reducing the response of the primary structure. Unlike TMDs, STMDs are capable of accommodating the changes in primary structure properties, due to damage or deterioration, by tuning in real time based on a local feedback. In this paper, a novel adaptive-length pendulum (ALP) damper is developed and experimentally verified. Length of the pendulum is adjusted in real time using a shape memory alloy (SMA) wire actuator. This can be achieved in two ways i) by changing the amount of current in the SMA wire actuator or ii) by changing the effective length of current carrying SMA wire. Using an instantaneous frequency tracking algorithm, the dominant frequency of the structure can be tracked from a local feedback signal, then the length of pendulum is adjusted to match the dominant frequency. Effectiveness of the proposed ALP-STMD mechanism, combined with the STFT frequency tracking control algorithm, is verified experimentally on a prototype two-storey shear frame. It has been observed through experimental studies that the ALP-STMD absorbs most of the input energy associated in the vicinity of tuned frequency of the pendulum damper. The reduction of storey displacements up to 80 % when subjected to forced excitation (harmonic and chirp-signal) and a faster decay rate during free vibration is observed in the experiments.