• Title/Summary/Keyword: Domestic hot water

Search Result 114, Processing Time 0.024 seconds

Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Review on the Effectiveness of Apartments According to Insulation Reinforcement of Energy Saving Design Standard - Energy Cost Analysis of Space Heating and Domestic Hot Water - (에너지절약설계기준의 단열 변화에 따른 공동주택 실효성 검토 - 난방 및 급탕에너지 사용금액 분석 -)

  • Kim, Ji-hyeon;Lim, Hee-won;Lee, Hyun-seung;Shin, U-cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.173-178
    • /
    • 2020
  • In this study, we analyzed space heating and domestic hot water(DHW) charges from 2017 to 2018 for 151,206 households in 202 apartment complexes built from 1997 to 2016, in order to evaluate the effectiveness of Korea's insulation standards reinforcement. The applied insulation standards were revised three times(in 1987, 2001 and 2010). We used the Anderson-Darling test to review the normality of the space heating and DHW charges. As a result, each p-value was greater than 0.05 and it followed the normal distribution. The annual average space heating charges per unit area of apartments with the 1987 insulation standards were 5,237₩/㎡a in 2017 and 5,328₩/㎡a in 2018. The heating charges with the 2001 standards were 4,827₩/㎡a in 2017 and 4,817₩/㎡a in 2018. Compared to previous standards(1987 standards), heating charges decreased by 7.8% and 9.6%. Also the heating charges with the 2010 standards were 3,683₩/㎡a in 2017 and 3,734₩/㎡a in 2018. Compared to previous standards(2001 standards), heating charges decreased by 24.3% and 21.5%. On the other hand, compared to each previous standards, DHW charges were decreased by 12.2%, 13.6% or increased by 4.6%, 6.9%, which means there's no correlation between insulation standards reinforcement and DHW charges.

Characterization of Foreign Undergrounded Distribution Cables (외국 지중배전케이블의 특성분석)

  • 고정우;오우정;김종은;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.428-431
    • /
    • 1997
  • In order to compare with domestic underground distribution cables, the foreign cable which was manufactured in USA, 1982 and has been serviced in field for 13 years was characterized with several tests. Water trees, voids, and convolutions are not found in insulation. In hot oil test, insulation is very clean and there was no separation of insulation and conductor shield. The results of degree of crosslinking, FTIR, and DSC are also usual. Specially, the distribution of OIT is very good, which is different from that of domestic cables. The content of impurities is relatively small. This cables was manufactured with good state and no extraordinary degradation is found.

  • PDF

A Numerical Study on the Flow Characteristics of Temperature Control Valve by Pressure Compensation (압력 평형식 온도조절 밸브 내부 유동 특성에 대한 수치적 연구)

  • Hwang, J.H.;Kim, T.A.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.448-453
    • /
    • 2005
  • Temperature Control Valve (TCV) is one of the useful temperature control devices, which is used to control constant temperature of working fluid in power and chemical plants and domestic water supply systems. TCV is composed of body, cylinder and piston, and the body shape has a symmetrical H-type. In general, it has several inlet and outlet holes, and its shape is like as tubular sleeve. The piston has three rings two rings of the end of piston have the function of controlling inlet flow rate with hot and cold working fluids, the center ring has the function of preventing hot and cold water from intermixing. Consequently, the shapes of piston and cylinder are the main design parameters in the performance of TCV. In this study, numerical analyses were carried out with two different piston and cylinder shapes to investigate the functions as a temperature control valve and the flow characteristics according to piston opening grade in TCV. Using a commercial code, FLUENT, velocity and pressure fields in TCV are obtained under steady, standard $k -{\epsilon}$ turbulence model and no-slip condition.

  • PDF

A Study on the Field Test of the Solar Heating System with Parabolic Solar Collectors Integrated the Roof of a Residential Building (지붕대체형 집광집열기를 이용한 태양열 난방시스템의 동절기 성능 평가)

  • Kim, Yong-Ki;Lee, Tae-Won;Yoon, Kwang-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • The final energy consumption in the building sector in Korea represents almost 20% of the total energy consumption. Besides, Space heating and hot water generation in Korea are based on fossil fuels, with a serious environmental impact. Despite the popularity of simple solar domestic hot water systems, active solar space heating remains, for various reasons, marginal. And thus, the aim of this paper is to demonstrate potentialities of solar assisted space heating systems, both technically and economically. From this study found that the solar heating system with CPC solar collectors integrated the roof of a single-story residential building shares $50{\sim}55%$ of the annual heating load.

Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator (쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구)

  • Lee, Geum-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

Thermal Effluent Effects of Domestic Sewage and Industrial Wastewater on the Water Quality of Three Small Streams (Eung, Chiljang and Buso) during the Winter Season, Korea (동계 저온기의 소하천 수질에 미치는 하·폐수의 온배수 영향)

  • Soon-Jin, Hwang;Jeon, Gyeonghye;Eum, Hyun Soo;Kim, Nan-Young;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.2
    • /
    • pp.238-253
    • /
    • 2017
  • The sewage and wastewater (SAW) are a well-known major source of eutrophication and greentide in freshwaters and also a potential source of thermal pollution; however, there were few approaches to thermal effluent of SAW in Korea. This study was performed to understand the behavioral dynamics of the thermal effluents and their effects on the water quality of the connected streams during winter season, considering domestic sewage, industrial wastewater and hot spring wastewater from December 2015 to February 2016. Sampling stations were selected the upstream, the outlet of SAW, and the downstream in each connected stream, and the water temperature change was monitored toward the downstream from the discharging point of SAW. The temperature effect and its range of SAW on the stream were dependent not only on the effluent temperature and quantity but also on the local air temperature, water temperature and stream discharge. The SAW effects on the stream water temperature were observed with temperature increase by $2.1{\sim}5.8^{\circ}C$ in the range of 1.0 to 5.5 km downstream. Temperature effect was the greatest in the hot spring wastewater despite of small amount of effluent. The SAW was not only related to temperature but also to the increase of organic matter and nutrients in the connected stream. The industrial wastewater effluent was discharged with high concentration of nitrogen, while the hot spring wastewater was high in both phosphorus and nitrogen. The difference between these cases was due to with and without chemical T-P treatment in the industrial and the hot spring wastewater, respectively. The chlorophyll-a content of the attached algae was high at the outlet of SAW and the downstream reach, mostly in eutrophic level. These ecological results were presumably due to the high water temperature and phosphorus concentration in the stream brought by the thermal effluents of SAW. These results suggest that high temperature of the SAW needs to be emphasized when evaluating its effects on the stream water quality (water temperature, fertility) through a systematized spatial and temporal investigation.

Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater (상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증)

  • Baek, Seung Man;Zhong, Yiming;Nam, Jin Hyun;Chung, Jae Dong;Hong, Hiki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In a solar domestic hot water (SDHW) system, solar energy is collected using collector panels, transferred to a circulating heat transfer fluid (brine), and eventually stored in a thermal storage tank (TST) as hot water. In this study, a computational fluid dynamics (CFD) model was developed to predict the solar thermal energy storage in a hybrid-type TST equipped with a helical jacket heater (mantle heat exchanger) and an immersed spiral coil heater. The helical jacket heater, which is the brine flow path attached to the side wall of a TST, has advantages including simple system design, low brine flow rate, and enhanced thermal stratification. In addition, the spiral coil heater further enhances the thermal performance and thermal stratification of the TST. The developed model was validated by the good agreement between the CFD results and the experimental results performed with the hybrid-type TST in SDHW settings.