• Title/Summary/Keyword: Domestic hot water

Search Result 114, Processing Time 0.029 seconds

A Study on the High Temperature Properties (Compressive Strength, Expansion) of Synthetic Sand using Domestic Silica Sand (Mooryang Silica Sand) (국내규사(國內硅砂)를 사용(使用)한 합성사(合成砂)의 고온성질(高溫性質) (압축강도(壓縮强度), 팽장(膨張)) 에 관(關)한 연구(硏究))

  • Yun, Byung-Guk;Lee, Kye-Wan
    • Journal of Korea Foundry Society
    • /
    • v.2 no.4
    • /
    • pp.2-8
    • /
    • 1982
  • The behavior of sand and mold at high temperatures was generally agreed to importantly affect the quality of castings made. By changing water content through 2,4,6 and 8%, and bentonite content through 5,7,9 and 11%, specimens have been made according to the respective composition. Specimens have been subjected to hot compressive strength and thermal expansion at 400, 600, 800 and $1000^{\circ}C$ respectively. The results obtained were as follows ; 1. At each temperature, thermal expansion decreased and hot compressive strength increased with the increase in water content. 2. After thermal expansion was peaked at approximately $1000^{\circ}C$ the contraction and maximum hot compressive strength appeared. 3. At each temperature, maximum hot compressive strength appeared 2%, 4,6% and 8% water content for 7%, 9% and 11% bentonite content respectively. 4. When 2% $H_2O$ was added, though bentonite content was increased, hot compressive strength did not rarely change. 5. Until the thermal expansion was completed the required time was 15-18 minutes at $400^{\circ}C$ and $600^{\circ}C$, and 10-13 minutes at $800^{\circ}C$. At $1000^{\circ}C$, the required time was 7-9 minutes in order to gain the maximum expansion, after that, contraction proceeded during 3-4 minutes before expansion was completed.

  • PDF

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

An Experimental and Field Study on Thermal Performance of Thermosyphon Solar Hot Water System (자연대류형 태양열 온수 급탕 시스템의 열성능 및 실증실험)

  • Kang, Y.H.;Kwak, H.Y.;Jeon, H.S.
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.16-26
    • /
    • 1991
  • This paper studies development of a solar thermosyphon hot water system which is suitable to korean climate and life style, to save energy consumed for domestic water heating. The system consists of two flat plate collectors(or three flat plate collectors) connected in parallel and a storage tank of 300 liter capacity with heat exchanger and the optimum system was designed through the comparative measurements of five different storage tanks. The developed system manufactured with domestic materials were installed in residential buildings in seven cities(Seoul, Pusan, Taegu, Kwangju, Taejeon, Kangneung, Cheju) for demonstration and field test and results show possibility for commercialization.

  • PDF

Development of Relief Valves for the Domestic Gas-fired Hot Water Boilers (가정용 가스보일러 과압방지밸브의 개발 연구)

  • Kim Young Gyu;Kwon Jeong Rock;Kim Ji Yoon;Suh Joon Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.63-68
    • /
    • 2000
  • We have developed a new relief valve which is a safety device for the domestic gas-fired hot water boilers. The relief valve has been designed to expand the inner diameter of the inlet, the outlet and the seat of the valve considering the relief capacity, and also to separate the spring from the room heating water. Therefore, we could minimize the adhesion and/or obstruction of the inlet and the corrosion phenomena of the spring which used to be the problem of the conventional relief valves. Test results of the developed relief valve showed that the performance of the opening pressure, reseating pressure, tightness, endurance were excellent, and the operating boiler with developed relief valve was evaluated as very good. The standardization and application of the relief valve can provide the advantage of component exchange and easy maintenance and repair.

  • PDF

A Study on the Optimum Application Method of Solar Thermal System to reduce Thermal Load and Carbon Emission in Apartment Building (공동주택의 열부하 및 탄소배출량 저감을 위한 태양열시스템의 최적 적용 방안 연구)

  • Yoon, Jong-Ho;Sim, Se-Ra;Shin, U-Cheul;Baek, Nam-Chun;Kwak, Hee-Yul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.135-142
    • /
    • 2011
  • Architectural market in the world is trying to develop Zero Carbon Buildng that doesn"t use fossil fuel. Residential building that thermal load such as heating and domestic hot water is over 70% in energy consumption is easy to make Zero Carbon Building compared with office building that is mainly electric load. So, As a preliminary for analyzing the effect of Solar thermal system in the building, an annual energy consumption of residential building and total heat loads are calculated. Based on this result, three alternatives of solar thermal system for hot water and heating are applied in the building while installation area is increasing. Solar thermal system is applied on balcony and roof of apartment building as the way to reduce thermal load. In the first case that solar thermal system for hot water is applied on the balcony, optimum installation area is $56m^2$. And you could install $40m^2$ of this system in the roof that angle is $30^{\circ}$. In the second case of solar thermal system for heating and hot water, you can install $40m^2$ on the roof. As a result of economic evaluation, the most economical application method is to install $40m^2$ of solar thermal system for only hot water on the roof of the building. At that time, you can payback the initial investing cost within 10 years. And carbon emission of this method can be reduced until about 4 ton per year.

An investigation on the actual condition of electrical facilities in domestic fountains (분수대 전기설비의 국내 적용실태분석)

  • Kim, H.S.;Kim, C.M.;Hwang, K.S.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.44-46
    • /
    • 2005
  • An Electrical facilities of fountain is one of the vulnerable facilities because it is exposed to water. Especially, some children enter the fountain and play in the water in the hot season. For example, death from electrical shock in fountain was reported in domestic and foreign papers. In this paper, we analyzed the riskiness of electrical shock on the basis of a fact-finding survey and comparing the domestic and international standard of electrical facilities in fountains.

  • PDF

Studies on the Utilization of Domestic Shale contained Chiastolite for Ceramics (국산 공정석함유 혈암의 요업적 개발에 관한 연구)

  • 정영기;오재현;이희수
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.3
    • /
    • pp.3-7
    • /
    • 1975
  • The usefulness of the domestic shale contained chiastolite as additive were investigated. Crude mixed minerals were separated into shale and chiastolite. Refractory body added simple component or multiple components as additives was obtained when firing at 125$0^{\circ}C$ for each body. Compressive strength, refractories, apparent sp. gr., water absorption, corrosion test by slag, hot linear expansion were measured and X-ray diffraction analysis was observed. As the result of study, refractory body contained separated minerals as additives showed slightly increasing in refractoriness, lowering in sintering effect, the excellent effect for corrosion resistance by acidic slag. With more containing separated minerals, hot linear expansion for the body can be decreased.

  • PDF

Skin-whitening effects of hot water extract from domestic edible mushrooms (국내 시판 식용버섯 열수 추출물의 피부미백 기능 연구)

  • Kim, Hyunjae;Jang, Byunghyun;Park, Kunhee;Jang, Gabyeol;Park, Kimoon
    • Journal of Mushroom
    • /
    • v.14 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Hot water extracts from 16 domestic edible mushrooms including Pleurotus ferulae (Lanzi) X.L. Mao, Lentinula edodes (Berk.) Pegler, and Hypsizygus marmoreus (Peck) H.E. Bigelow, which are commercially available, were used for determining the cosmetic potential of these mushrooms. In this study, we carried out in vitro functional experiments to determine the inhibitory effects of these extracts on L-DOPA oxidation of tyrosinase and melanin synthesis. Based on the results of these experiments, H. marmoreus (Peck) H.E. Bigelow No. 10 and No. 15 were selected for further analysis. We analyzed the melanin synthesis inhibitory activity, TRP1 and MITF expression via real-time PCR, and Fontana Masson staining in artificial skin $Neoderm^{(R)}-ME$. Taken together, we observed that the hot water extract from H. marmoreus (Peck) H.E. Bigelow (No. 15) had better whitening effect than the extracts of other mushrooms. Thus, it can be a potential source of skin-whitening agent.

Quality Characteristics and Antioxidant Characteristics of Sword Bean Tea Distributed in Domestic Markets (국내 시중 유통 작두콩차의 품질특성 및 항산화특성)

  • You-jin Park;Eom-ji Hwang;Gyeong-dan Yu;Koan Sik Woo
    • The Korean Journal of Food And Nutrition
    • /
    • v.37 no.2
    • /
    • pp.100-109
    • /
    • 2024
  • This study examined the quality characteristics and antioxidant properties of sword bean tea available in domestic markets. Each product of sword bean tea had distinct appearance characteristics. The color, pH, brownness, and turbidity of the tea varied significantly across different products, with tea bags showing higher levels of brownness and turbidity. The total polyphenol content of hot water extraction ranged from 165.13 to 517.69 mg gallic acid equivalents (GAE)/100 g sample for pod tea, 999.36 to 2,054.74 mg GAE/100 g sample for tea bag tea, and 74.62 to 275.00 mg GAE/100 g sample for grain tea, respectively. Similarly, the total flavonoid content, measured in terms of catechin equivalents (CE), ranged from 39.51 to 65.00 mg CE/100 g sample for pod tea, 86.57 to 253.63 mg CE/100 g sample for tea bag tea, and 32.94 to 38.63 mg CE/100 g sample for grain tea, for hot water extraction. The DPPH and ABTS radical scavenging activities of pod tea were 95.68 to 276.19 mg TE/100 g sample and 270.87 to 804.21 mg trolox equivalents/100 g sample, respectively, for hot water extraction. These results suggest the need to establish quality standards to ensure consistent quality of sword bean tea.