• 제목/요약/키워드: Domestic city gas

검색결과 48건 처리시간 0.024초

Research Investigations at the Municipal (2×35) and Clinical (2×5 MW) Waste Incinerators in Sheffield, UK

  • Swithenbank, J.;Nasserzadeh, V.;Ewan, B.C.R.;Delay, I.;Lawrence, D.;Jones, B.
    • 청정기술
    • /
    • 제2권2호
    • /
    • pp.100-125
    • /
    • 1996
  • After recycle of spent materials has been optimised, there remains a proportion of waste which must be dealt with in the most environmentally friendly manner available. For materials such as municipal waste, clinical waste, toxic waste and special wastes such as tyres, incineration is often the most appropriate technology. The study of incineration must take a process system approach covering the following aspects: ${\bullet}$ Collection and blending of waste, ${\bullet}$ The two stage combustion process, ${\bullet}$ Quenching, scrubbing and polishing of the flue gases, ${\bullet}$ Dispersion of the flue gases and disposal of any solid or liquid effluent. The design of furnaces for the burning of a bed of material is being hampered by lack of an accurate mathematical model of the process and some semi-empirical correlations have to be used at present. The prediction of the incinerator gas phase flow is in a more advanced stage of development using computational fluid dynamics (CFD) analysis, although further validation data is still required. Unfortunately, it is not possible to scale down many aspects of waste incineration and tests on full scale incinerators are essencial. Thanks to a close relationship between SUWIC and Sheffield Heat&Power Ltd., an extended research programme has been carried out ar the Bernard Road Incinerator plant in Sheffield. This plant consists of two Municipal(35 MW) and two Clinical (5MW) Waste Incinerators which provide district heating for a large part of city. The heat is distributed as hot water to commercial, domestic ( >5000 dwelling) and industrial buildings through 30km of 14" pipes plus a smaller pipe distribution system. To improve the economics, a 6 MW generator is now being added to the system.

  • PDF

사례분석을 통한 지하철 테러에 대한 대책 (Counter Measures of the Subway Terrorism through Case Analysis)

  • 권정훈;김태환;최종균
    • 시큐리티연구
    • /
    • 제18호
    • /
    • pp.1-20
    • /
    • 2009
  • 도시적 토지이용공간의 절대부족 등 도시의 제반문제들을 해결하기 위해 세계 각국뿐만 아니라 우리나라에서도 지속적으로 지하공간의 이용범위를 확대하고 있는 실정이다. 그러나 지하공간의 활용은 수많은 잠재력과 동시에 문제점들을 내포하고 있는 동전의 양면성을 지니고 있다. 특히, 9 11 테러 이후 발생되는 뉴테러리즘은 대중교통수단이나 다중이용시설 등에 대한 이른바, 'soft target'으로 변화되는 추세를 보이고 있다. 그 결과, 대표적인 예로 2003년 대구지하철 화재사고, 2005년 영국 런던지하철 연쇄폭탄테러사건 등 부정적 결과를 낳게 되었다. 이렇게 지하공간에 대한 안전사고 우려에도 불구하고 지하공간의 활용은 불가피한 선택이 될 수밖에 없으며 빠른 속도로 늘어나고 있는 실정이다. 그러나 우리나라는 아직까지 지하공간의 종합적인 테러대응책은 크게 미흡하여 보완대책마련이 시급한 실정이다. 따라서 본 연구는 테러관련 사건 중 국내 외의 지하철에서 발생된 피해사례를 통해 효율적인 대책을 제시하는데 그 목적이 있다. 테러발생으로 인해 피해를 최소화하기 위한 테러대응책을 요약하면 다음과 같다. 첫째, 테러발생으로 인한 화재나 유독가스로부터 지하공간 이용자들의 인명구조를 위한 방호 장비가 확보되어야 하고 둘째, 테러발생 시 신속한 행동을 통해 피해를 최소화하기 위한 현장대응 관리와 체계적인 교육훈련이 확립되어야 하며 셋째, 테러발생 시 불특정다수가 신속히 대피할 수 있는 지하공간의 대피로가 마련되어져야 하고 넷째, 체계적 전방위적인 대응을 위해 유관기관간의 네트워크망 형성이 필요하다. 마지막으로 사후수습을 위해서 사고피해자 및 유가족들에 대한 정부당국의 신속하고 전문적 서비스를 통한 피해대책이 마련되어져야 할 것이다.

  • PDF

화장로 형상 최적화를 통한 에너지효율개선을 위한 실증연구 (Field Scale Study for Energy Efficiency Improvement of Crematory System by the Shape Optimization of Combustion Chamber)

  • 원용태;이승목
    • 공업화학
    • /
    • 제30권5호
    • /
    • pp.546-555
    • /
    • 2019
  • 본 연구는 국내 화장로 설비의 주류를 이루는 대차방식 화장로의 성능개선을 목표로 하였다. 주연소실 형상 변화를 통해 용적을 증대시키고, 버너연소제어 최적화를 통한 화장시간 단축 및 에너지 사용량 절감기술을 실증설비 기반으로 연구하였다. 1차적으로 열유동해석을 통해 최적화된 구조설계로 주연소실의 체적을 약 70% 증대시키므로 연소배가스의 체류시간이 증대되는 효과를 얻을 수 있었고, 이를 통해 설계한 파이로트 화장로를 제작하여 다양한 운전조건에서 연소거동을 실험하고 주연소실 형상별 최적의 운전방안을 도출하였다. 이렇게 도출된 결과를 반영하여 실증 화장로를 설계하고, P시 Y화장장에 설치하였다. 실증 화장로 조업을 통해 최적 연소조건을 도출할 수 있었고, 고온의 연소배가스의 체류시간 증대에 따른 에너지 효율의 증대효과로 기존대비 화장시간 및 연료사용량을 최소화할 수 있었다. 즉, 화장시간은 기존 화장로 조업대비 44.1% 단축된 38 min이었고, 연료사용량은 기존 화장로 대비 54.4% 절감된 $21.8Nm^3$이었다.

유한요소법을 이용한 고압 CNG압력용기 응력분포 해석 (Stress Distribution Analysis for High Pressure CNG Pressure Vessel Using FEM)

  • 최상인;김영철;김명수;백태현
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제7권2호
    • /
    • pp.427-435
    • /
    • 2017
  • 환경문제로 국내 시내버스의 대부분은 압축천연가스(CNG)를 연료로 사용하며, 연료 저장용기는 내압을 받는 압력용기를 사용하고 있다. 내압을 받는 압력용기는 여러 가지의 형태와 목적을 지니고 있다. 연료가 가연성이고 고압으로 인한 폭발성을 지니고 있으므로 압력용기의 파손사고는 많은 재산피해와 인명피해를 일으킨다. 이에 대한 안전한 설계가 반드시 필요하므로 유한요소해석을 이용하여 많은 연구들이 진행되고 있다. 본 연구에서 유한요소 해석 소프트웨어인 ANSYS를 이용한 응력해석을 탄성이론의 구형 돔 형상 응력이론식과 실린더 형상 응력이론식을 비교하여 해석의 타당성을 입증 하기위해 돔의 형상이 완전 구형인 모델을 설계하여 관찰하였고 실제 사용중인 ASME 규격이론을 바탕으로 압축천연가스(CNG)로 설계된 모델에 대해서도 응력분포를 분석하였다. 유한요소 해석 소프트 웨어를 사용하여 돔 형상이 완전이 구형인 모델을 해석 하였을 때 이론과 잘 일치 하였고 ASME 규격이론을 바탕으로 설계한 모델에서는 너클부분에 응력집중 현상이 발생하였다.

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.

도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구 (A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns)

  • 이성원;심영종;나귀태
    • 한국터널지하공간학회 논문집
    • /
    • 제19권1호
    • /
    • pp.11-27
    • /
    • 2017
  • 서울시 등의 국내 주요 도심은 지역적 팽창에 따라 도로망 체계가 급격하게 발전하였고 도시민이 안락하고 풍요로운 생활을 영위하도록 전력, 통신, 상수도, 하수도, 냉 난방관로, 가스관 등이 무분별하게 개별 매설되었으며 비효율적으로 개별 관리되고 있다. 국토계획법에서는 Life-Line을 공동 수용함으로써 도로의 반복 굴착을 줄이고 도시 미관의 개선, 포장 내구성 향상에 따른 주행성능 향상 그리고 원활한 교통소통 등을 기대하는 도시계획 시설물로 공동구를 정의하고 있다. 최근 기존 도심지의 재정비 측면에서 쾌적한 도시공간 조성, 지하공간 이용 효율과 도로관리 효율 향상, 지진 및 도로함몰에 대한 재난안전성, 스마트 그리드와 전기자동차 보급과 같은 미래 생활환경 변화에 대한 신속한 대응 등을 기대할 수 있는 기존 도심지의 공동구 설치 필요성이 증가하고 있으나 국내에 설치된 모든 공동구는 신도시 개발에 따라 계획된 Life-Line을 모두 수용하도록 설치한 개착식 공동구 형태이다. 기존 도심지에서는 현재 가동중인 모든 Life-line을 모두 수용할 수 없으므로 도심지 유형별 공동구 설치 타당성 평가시스템을 활용한 설계용량 최적화 등의 새로운 연구가 필요하다. 본 연구는 신도시 공동구를 탈피하고 기존 도심지를 대상으로 평가지표에 의한 정량적 평가모델을 제시 하는 등 유형별 타당성 평가시스템을 세분화하며 정량적 평가시스템의 구현이 가능한 프로그램을 개발해 궁극적으로 도심지 공동구 활성화에 기여하고자 한다.

도로수송부문 온실가스 배출량 산정을 위한 간선 및 지선도로상의 교통량 추정시스템 개발 (Development of Traffic Volume Estimation System in Main and Branch Roads to Estimate Greenhouse Gas Emissions in Road Transportation Category)

  • 김기동;이태정;정원석;김동술
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.233-248
    • /
    • 2012
  • The national emission from energy sector accounted for 84.7% of all domestic emissions in 2007. Of the energy-use emissions, the emission from mobile source as one of key categories accounted for 19.4% and further the road transport emission occupied the most dominant portion in the category. The road transport emissions can be estimated on the basis of either the fuel consumed (Tier 1) or the distance travelled by the vehicle types and road types (higher Tiers). The latter approach must be suitable for simultaneously estimating $CO_2$, $CH_4$, and $N_2O$ emissions in local administrative districts. The objective of this study was to estimate 31 municipal GHG emissions from road transportation in Gyeonggi Province, Korea. In 2008, the municipalities were consisted of 2,014 towns expressed as Dong and Ri, the smallest administrative district unit. Since mobile sources are moving across other city and province borders, the emission estimated by fuel sold is in fact impossible to ensure consistency between neighbouring cities and provinces. On the other hand, the emission estimated by distance travelled is also impossible to acquire key activity data such as traffic volume, vehicle type and model, and road type in small towns. To solve the problem, we applied a hierarchical cluster analysis to separate town-by-town road patterns (clusters) based on a priori activity information including traffic volume, population, area, and branch road length obtained from small 151 towns. After identifying 10 road patterns, a rule building expert system was developed by visual basic application (VBA) to assort various unknown road patterns into one of 10 known patterns. The expert system was self-verified with original reference information and then objects in each homogeneous pattern were used to regress traffic volume based on the variables of population, area, and branch road length. The program was then applied to assign all the unknown towns into a known pattern and to automatically estimate traffic volumes by regression equations for each town. Further VKT (vehicle kilometer travelled) for each vehicle type in each town was calculated to be mapped by GIS (geological information system) and road transport emission on the corresponding road section was estimated by multiplying emission factors for each vehicle type. Finally all emissions from local branch roads in Gyeonggi Province could be estimated by summing up emissions from 1,902 towns where road information was registered. As a result of the study, the GHG average emission rate by the branch road transport was 6,101 kilotons of $CO_2$ equivalent per year (kt-$CO_2$ Eq/yr) and the total emissions from both main and branch roads was 24,152 kt-$CO_2$ Eq/yr in Gyeonggi Province. The ratio of branch roads emission to the total was 0.28 in 2008.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.